{"id":2386,"date":"2025-12-31T12:52:57","date_gmt":"2025-12-31T12:52:57","guid":{"rendered":"https:\/\/xbrele.com\/?p=2386"},"modified":"2026-05-25T15:17:45","modified_gmt":"2026-05-25T15:17:45","slug":"top-10-vacuum-contactor-manufacturers-guide","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/top-10-vacuum-contactor-manufacturers-guide\/","title":{"rendered":"\u0bae\u0bc1\u0ba4\u0bb2\u0bcd 10 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 + \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd + OEM \u0baa\u0b95\u0bcd\u0b95\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)"},"content":{"rendered":"\ufeff\n<p>\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bb5\u0ba3\u0bbf\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2. 12 kV, 400 A, AC-4 \u0b8e\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 40% \u0b8e\u0ba9 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u201c\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd\u201d \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u201c\u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bae\u0bcd\u0baa\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b87\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb2\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd\u201d \u0bb5\u0bb0\u0bc8 \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb1\u0b95\u0bc1, OEM \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4 \u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0ba8\u0bcd\u0ba4 \u0baa\u0bbf\u0bb1\u0b95\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0ba8\u0bcd\u0ba4 \u0bb5\u0b9a\u0ba4\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bbf\u0baf \u0baa\u0bbf\u0bb1\u0b95\u0bc1, \u0b85\u0ba4\u0bbe\u0bb5\u0ba4\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 18 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0ba9\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8 \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1: \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b86\u0ba4\u0bb0\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9f\u0baf\u0bb0\u0bcd-1 \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf \u0bb5\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 OEM \u0b9a\u0baa\u0bcd\u0bb3\u0bc8\u0baf\u0bb0\u0bcd\u0b95\u0bb3\u0bcd. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bb0\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0b95\u0bca\u0bb3\u0bcd\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0bb2 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf 10 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd\u0b95\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bcd, \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb3 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8. \u0b87\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1, \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 (\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd, \u0ba8\u0bc0\u0bb0\u0bcd\/\u0b95\u0bb4\u0bbf\u0bb5\u0bc1\u0ba8\u0bc0\u0bb0\u0bcd, HVAC) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd OEM \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-contactor-manufacturer-comparison-matrix\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bb3\u0bae\u0bcd<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0ba8\u0bb0\u0bcd \u0bb5\u0b95\u0bc8<\/th><th>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8<\/th><th>\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/th><th>\u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bb0\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/th><\/tr><\/thead><tbody><tr><td>\u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bcd<\/td><td>\u0baa\u0bb0\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bb3\u0bae\u0bcd, \u0bae\u0bc1\u0ba4\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1.<\/td><td>\u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b9a\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bb5\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b9a\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/td><td>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8, \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba8\u0bc6\u0b95\u0bbf\u0bb4\u0bcd\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8.<\/td><\/tr><tr><td>XBRELE \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8-\u0ba8\u0bc7\u0bb0\u0b9f\u0bbf MV \u0ba8\u0bbf\u0baa\u0bc1\u0ba3\u0bb0\u0bcd<\/td><td>\u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0baf\u0ba9\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1, \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0ba4\u0bb0\u0bb5\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0bae\u0bcd.<\/td><td>OEM \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bcd, \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd, \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9f\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb0\u0bc6\u0b9f\u0bcd\u0bb0\u0bcb\u0b83\u0baa\u0bbf\u0b9f\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/td><td>\u0b86\u0bb0\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0baa\u0ba3\u0bbf \u0bb5\u0b95\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0baa\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/td><\/tr><tr><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0ba8\u0bb0\u0bcd<\/td><td>\u0b8e\u0bb3\u0bbf\u0baf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8.<\/td><td>\u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf, \u0b89\u0bb3\u0bcd\u0bb3\u0bc2\u0bb0\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd.<\/td><td>\u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b86\u0bb4\u0bae\u0bcd, \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb1\u0bcd\u0baa\u0ba9\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b86\u0ba4\u0bb0\u0bb5\u0bc1.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"when-to-choose-xbrele-for-vacuum-contactor-projects\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 XBRELE-\u0b90\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd<\/h2>\n\n\n\n<p>\u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0b85\u0ba4\u0ba9\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 XBRELE-\u0b90\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0bb8\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b9f\u0bbf\u0b99\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd, \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd, \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95 \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd, \u0b89\u0baf\u0bb0\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb0\u0bc6\u0b9f\u0bcd\u0bb0\u0bcb\u0b83\u0baa\u0bbf\u0b9f\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1. \u0b87\u0ba4\u0ba9\u0bcd \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bca\u0bb3\u0bcd\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bcb\u0bb3\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0ba4\u0bb2\u0bcd\u0bb2, \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-contactor-rfq-checklist\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf RFQ \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8, \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li><li>\u0b9a\u0bc1\u0bae\u0bc8 \u0bb5\u0b95\u0bc8: \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd, \u0b95\u0baa\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd, \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95 \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf.<\/li><li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8, \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0b95\u0bc8, \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd.<\/li><li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/li><li>\u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd, \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb2\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-manufacturer-selection-determines-total-cost-of-ownership\">\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8f\u0ba9\u0bcd \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b89\u0bb0\u0bbf\u0bae\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0baf\u0bbe\u0ba4\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1: \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\/\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (\u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b87\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\/\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd). \u0bae\u0bb2\u0bbf\u0bb5\u0bbe\u0ba9 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bbf\u0bb2\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0b9f\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0b9f\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 1 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 50,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0b9f\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0ba4\u0bcb\u0bb0\u0bbe\u0baf\u0bae\u0bbe\u0ba9 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc8 \u0b85\u0b9f\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95, \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 ... \u0b89\u0b9f\u0ba9\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. <a href=\"https:\/\/xbrele.com\/ta\/mechanical-life-vs-electrical-life-contactor-endurance\/\">\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/a>.<\/p>\n\n\n\n<p><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0bae\u0bc8<\/strong>&nbsp;\u0b85\u0ba4\u0bbf\u0b95-\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc8\u0baf\u0bb5\u0bbf\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bae\u0bcd\u0baa\u0bcd \u0bb8\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd: 200\u2013500 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\/\u0ba8\u0bbe\u0bb3\u0bcd<\/li>\n\n\n\n<li>HVAC \u0b9a\u0bbe\u0b83\u0baa\u0bcd\u0b9f\u0bcd-\u0bb8\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd: 10\u201350 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\/\u0ba8\u0bbe\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd: 100\u2013300 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\/\u0ba8\u0bbe\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<p>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u00a0<strong>1 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u00a0\u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bc8\u0b95\u0bcd\u0b95\u0bc1 200 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1\u00a0<strong>13.7 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u00a0(1,000,000 \/ 200 \/ 365). 500,000 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1\u00a0<strong>6.8 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u2014\u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8 \u0b87\u0bb0\u0b9f\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd.<\/p>\n\n\n\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd<\/strong>&nbsp;\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. IEC 62271-106, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8 AC-4 (\u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0ba3\u0bbf, \u0b85\u0ba4\u0bbf\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd)\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b89\u0b9f\u0ba9\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/74487\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 60947-4-1<\/a>. 150 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 8,000\u201312,000 AC-4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd 3,000\u20135,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bb5\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bb3\u0bcd<\/a>&nbsp;\u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/a>&nbsp;\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b9a\u0bc2\u0bb4\u0bb2\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01.webp\" alt=\"\u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd, \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0baa\u0bcd\u0bb3\u0bc8\u0baf\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bae\u0bbf\u0b9f\u0bc1\" class=\"wp-image-2387\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-tier-pyramid-comparison-fig-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd-01: \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0bae\u0bca\u0bb4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0ba4\u0bbf\u0baa\u0bb2\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0ba8\u0bbf\u0bb2\u0bc8-1 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b86\u0baf\u0bc1\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b86\u0ba4\u0bb0\u0bb5\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8-3 \u0b85\u0ba4\u0bbf\u0b95 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-1-global-premium-manufacturers\">\u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 1: \u0b89\u0bb2\u0b95\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1.-abb-switzerlandsweden\">1. \u0b8f\u0baa\u0bbf\u0baa\u0bbf (\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bb0\u0bcd\u0bb2\u0bbe\u0ba8\u0bcd\u0ba4\u0bc1\/\u0bb8\u0bcd\u0bb5\u0bc0\u0b9f\u0ba9\u0bcd)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: VM1, VD4H (\u0b95\u0bb2\u0baa\u0bcd\u0baa\u0bbf\u0ba9 VCB\/\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 3.6\u201340.5 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 1,000,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8 (IEC 62271-106-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 10,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>ABB \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9. VM1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd, \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd, \u0ba4\u0b99\u0bcd\u0b95 \u0bae\u0bc1\u0bb2\u0bbe\u0bae\u0bcd \u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0b83\u0baa\u0bc7\u0bb8\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bc1\u0ba3\u0bc8 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd KEMA (\u0ba8\u0bc6\u0ba4\u0bb0\u0bcd\u0bb2\u0bbe\u0ba8\u0bcd\u0ba4\u0bc1) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd CPRI (\u0b87\u0ba8\u0bcd\u0ba4\u0bbf\u0baf\u0bbe) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bc6\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0b95 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0bae\u0bc8 (\u0b95\u0b9f\u0bb2\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd \u0baa\u0bae\u0bcd\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 1.2 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bcd)<\/li>\n\n\n\n<li>80-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 48 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0ba4\u0bbf\u0bb0\u0bbf\u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0baa\u0bc2\u0b95\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0b95\u0bc1\u0ba4\u0bbf \u0b89\u0b9f\u0bcd\u0baa\u0b9f, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 IEC\/IEEE \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 25\u201340% \u0bb5\u0bbf\u0bb2\u0bc8 \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0baf\u0ba9\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 12\u201316 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8 \u0b95\u0bbe\u0bb2 \u0b85\u0bb5\u0b95\u0bbe\u0b9a\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1 HVAC \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0b95\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0b85\u0ba3\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b95\u0b9f\u0bb2\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd \u0b89\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0bb0\u0bbf\u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2.-schneider-electric-france\">2. \u0bb7\u0bcd\u0ba9\u0bc0\u0b9f\u0bb0\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd (\u0baa\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: \u0bb0\u0bc0\u0b95\u0bcd\u0bb3\u0bcb\u0b9a\u0bb0\u0bcd-M, SM6 (RMU \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 7.2\u201324 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 500,000\u20131,000,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 8,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0bb7\u0bcd\u0ba9\u0bc0\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0ba4\u0bcd\u0ba4\u0bbf, IIoT \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbf\u0bb3\u0bb5\u0bc1\u0b9f\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b88\u0b95\u0bcb\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0b95\u0bcd\u0b9a\u0bb0\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. SM6 \u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd, \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b9f\u0bc1 \u0bb2\u0bcb\u0b9f\u0bcd-\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0baa\u0bb2\u0bae\u0bbe\u0ba9, \u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 SCADA\/\u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0bae\u0bbe\u0b9f\u0bcd\u0baa\u0bb8\u0bcd, IEC 61850)<\/li>\n\n\n\n<li>\u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0baa\u0baf\u0bbf\u0bb1\u0bcd\u0b9a\u0bbf\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba9\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 (RMU-\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b95)<\/li>\n\n\n\n<li>\u0ba4\u0bc2\u0baf \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1<\/li>\n\n\n\n<li>\u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbe\u0bb5\u0bc8 \u0bae\u0bc8\u0baf\u0bae\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0b86\u0b9a\u0bbf\u0baf\u0bbe-\u0baa\u0b9a\u0bbf\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9\u0ba4\u0bc1)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0bb8\u0bcd\u0bae\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b95\u0bbf\u0bb0\u0bbf\u0b9f\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b8e\u0bb0\u0bbf\u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3.-eaton-usaireland\">3. \u0b88\u0b9f\u0ba9\u0bcd (\u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe\/\u0b90\u0bb0\u0bcd\u0bb2\u0bbe\u0ba8\u0bcd\u0ba4\u0bc1)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: VCP-W, \u0bae\u0bc7\u0b95\u0bcd\u0ba9\u0bae\u0bcd DS (\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 4.16\u201315 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 600,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 6,000\u20138,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0b88\u0b9f\u0ba9\u0bcd, UL\/CSA \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1-\u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bb5\u0b9f \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bb3\u0bc8 \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. VCP-W \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf, IEEE C37.20.7-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf \u0bb5\u0b95\u0bc8 2B \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1-\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0bb0\u0bbf\u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0b9a\u0ba4\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0ba4\u0bbf\u0b9a\u0bc8 \u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1)<\/li>\n\n\n\n<li>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0b9f \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd (30+ \u0b9a\u0bc7\u0bb5\u0bc8 \u0bae\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0bb4\u0bc8\u0baf \u0b95\u0b9f\u0bcd\u0bb2\u0bb0\u0bcd-\u0bb9\u0bc7\u0bae\u0bb0\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bc1 (\u0baa\u0bb4\u0bc8\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0b9f \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bbf\u0bb0\u0b9a\u0ba9\u0bcd\u0ba9\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (4.16 kV, 13.8 kV-\u0b87\u0bb2\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0b87\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0ba4\u0bbf \u0bb5\u0bb0\u0bbf \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b86\u0b9a\u0bbf\u0baf \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>\u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0b86\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd (MSHA \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0bae\u0bcd), \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bca\u0bb3\u0bbf \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-2-industrial-oem-specialists\">\u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 2: \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 OEM \u0ba8\u0bbf\u0baa\u0bc1\u0ba3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4.-xbrele-china\">4. \u0b8e\u0b95\u0bcd\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bcd\u0bb2\u0bc7 (\u0b9a\u0bc0\u0ba9\u0bbe)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: CKG3, CKG4 (\u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8), JCZ (\u0b95\u0bb0\u0bbf \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 3.6\u201312 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 1,000,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (IEC 62271-106 \u0baa\u0b9f\u0bbf M2 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 8,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0b8e\u0b95\u0bcd\u0bb8\u0bcd\u0baa\u0bbf\u0b86\u0bb0\u0bcd\u0b87\u0b8e\u0bb2\u0bcd\u0b87\u0b87 \u0b92\u0bb0\u0bc1 \u0b86\u0b95 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor-vs-vacuum-circuit-breaker-medium-voltage-panel\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf OEM \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd<\/a>&nbsp;\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba9\u0bb0\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bbf\u0bb2\u0bcd 15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb2\u0bbe\u0ba9 \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd. \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bb5\u0bbf\u0bb2\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bae\u0bcd, \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bb8\u0bcd\u0ba4\u0bb0\u0bcd \u0bb2\u0bbe\u0baa \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd CESI (\u0b87\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bbf) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd KEMA \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd IEC \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b92\u0ba4\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 30\u201350%-\u0b87\u0ba9\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0b95\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (Ex d IIB, \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd MA)<\/li>\n\n\n\n<li>\u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0baf\u0ba9\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 7-\u0ba8\u0bbe\u0bb3\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0bc1\u0bb4\u0bc1\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 (\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bb8\u0bcd\u0ba4\u0bb0\u0bcd \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bb0\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b86\u0b9a\u0bbf\u0baf\u0bbe-\u0baa\u0b9a\u0bbf\u0baa\u0bbf\u0b95\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7\u0baf\u0bbe\u0ba9 \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0b86\u0b99\u0bcd\u0b95\u0bbf\u0bb2 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bca\u0bb4\u0bbf\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8.<\/li>\n\n\n\n<li>\u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0baf \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bcd \u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bbe\u0bb0\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95 OEM-\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5.-ls-electric-south-korea\">5. \u0b8e\u0bb2\u0bcd\u0b8e\u0bb8\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd (\u0ba4\u0bc6\u0ba9\u0bcd \u0b95\u0bca\u0bb0\u0bbf\u0baf\u0bbe)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: VCF-12, VCC (\u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 7.2\u201324 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 500,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 6,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>LS \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd (\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd LG \u0b87\u0ba3\u0bcd\u0b9f\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bae\u0bcd\u0bb8\u0bcd) \u0b87\u0b9f\u0bae\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bc8\u0baf\u0bc1\u0bb3\u0bcd\u0bb3 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b85\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bb3 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. VCF-12 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, ABB VM1-\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bae\u0bae\u0bbe\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0b9f 30% \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b85\u0b95\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0b9f\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bb4\u0bc8\u0baf GIS \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0ba3\u0bbf \u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (12 kV, 400 A-\u0b95\u0bcd\u0b95\u0bc1 165 \u0bae\u0bbf\u0bae\u0bc0 \u0b85\u0b95\u0bb2\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0ba4\u0bc6\u0ba9\u0bcd \u0b95\u0bca\u0bb0\u0bbf\u0baf\u0bbe, \u0ba4\u0bc6\u0ba9\u0bcd\u0b95\u0bbf\u0bb4\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0b9a\u0bbf\u0baf \u0b95\u0baa\u0bcd\u0baa\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf \u0bb5\u0bbf\u0bb2\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bae\u0bcd (ABB-\u0b95\u0bcd\u0b95\u0bc1 20% \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95, \u0b9a\u0bc0\u0ba9 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bc1 15% \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9f\u0baf\u0bb0\u0bcd-1-\u0b90 \u0bb5\u0bbf\u0b9f \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd (500k vs 1M \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0b86\u0b9a\u0bbf\u0baf\u0bbe\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b9a\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0b99\u0bcd\u0b95\u0bbf\u0bb2 \u0bae\u0bca\u0bb4\u0bbf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0b95\u0b9f\u0bb2\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0b95\u0bca\u0bb0\u0bbf\u0baf \u0b95\u0baa\u0bcd\u0baa\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bb1\u0bc1\u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, OEM \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"6.-siemens-germany\">6. \u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd (\u0b9c\u0bc6\u0bb0\u0bcd\u0bae\u0ba9\u0bbf)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: 3AH (\u0baa\u0bbe\u0bb0\u0bae\u0bcd\u0baa\u0bb0\u0bbf\u0baf), \u0b9a\u0bbf\u0bae\u0bcb\u0bb5\u0bbe\u0b95\u0bcd (VCB-\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b95\u0bb2\u0baa\u0bcd\u0baa\u0bbf\u0ba9)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 7.2\u201340.5 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 500,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 7,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd \u0ba4\u0ba9\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bb5\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8, \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 (\u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd) \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0b9f\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bae\u0bcb\u0bb5\u0bbe\u0b95\u0bcd (SIMOVAC) \u0b95\u0bb2\u0baa\u0bcd\u0baa\u0bbf\u0ba9 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0ba4\u0bc1. \u0ba4\u0bc2\u0baf \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (3AH \u0ba4\u0bca\u0b9f\u0bb0\u0bcd) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0bae\u0bbe\u0b9f\u0bc1\u0bb2\u0bb0\u0bcd VCB \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0ba4\u0bb0\u0bb5\u0bbe\u0b95 \u0b85\u0bb5\u0bc8 \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd SIPROTEC \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd TIA \u0baa\u0bcb\u0bb0\u0bcd\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0b86\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bc7\u0bb7\u0ba9\u0bc1\u0b9f\u0ba9\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0ba4\u0bb0\u0bb5\u0bc1<\/li>\n\n\n\n<li>\u0b9c\u0bc6\u0bb0\u0bcd\u0bae\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0ba4\u0bcd \u0ba4\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd VCB-\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0bb2\u0bae\u0bcd (16\u201320 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"tier-3-volume-chinese-manufacturers\">\u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 3: \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"7.-shandong-taikai-china\">7. \u0bb7\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b99\u0bcd \u0ba4\u0bc8\u0b95\u0bc8 (\u0b9a\u0bc0\u0ba9\u0bbe)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: CKG, CKGB (\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 6\u201312 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 300,000\u2013500,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 4,000\u20136,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0b9f\u0bbf\u0b95\u0bbe\u0baf\u0bcd, \u0b9a\u0bc0\u0ba9\u0bbe\u0bb5\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 OEM \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bcb\u0b9f\u0bc1, \u0bb5\u0bbf\u0bb2\u0bc8 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bb0\u0bcd\u0bb5\u0ba4\u0bc7\u0b9a \u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0ba4\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 2015 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0b95 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1\u2014\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 IEC \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0b9f\u0bc8\u0baf\u0bc7 \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 (\u0b9f\u0baf\u0bb0\u0bcd-1-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 40\u201360%)<\/li>\n\n\n\n<li>\u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd ( \u0b95\u0bc8\u0baf\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 4 \u0bb5\u0bbe\u0bb0 \u0b95\u0bbe\u0bb2 \u0b85\u0bb5\u0b95\u0bbe\u0b9a\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0ba4\u0bb0\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bb5\u0bb3\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba4\u0bca\u0b95\u0bc1\u0ba4\u0bbf\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bcd (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u00b120%)<\/li>\n\n\n\n<li>\u0b9a\u0bb0\u0bcd\u0bb5\u0ba4\u0bc7\u0b9a \u0bb5\u0bbe\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b89\u0ba4\u0bbf\u0bb0\u0bbf\u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b9a\u0bcd \u0b9a\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bbf \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0baf\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (\u0b9a\u0bbf\u0bb2 \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba9, \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3\u0ba9)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0bb5\u0bb0\u0bb5\u0bc1\u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc0\u0ba9 OEM-\u0b95\u0bb3\u0bcd, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"8.-nanjing-electric-china\">8. \u0ba8\u0ba9\u0bcd\u0b9c\u0bbf\u0b99\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd (\u0b9a\u0bc0\u0ba9\u0bbe)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: JN15, JN27 (\u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bae\u0bcd\u0baa \u0bb5\u0b95\u0bc8)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 12\u201327.5 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 500,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 5,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0ba8\u0bbe\u0ba9\u0bcd\u0b9c\u0bbf\u0b99\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd (\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd \u0ba8\u0bbe\u0ba9\u0bcd\u0b9c\u0bbf\u0b99\u0bcd \u0b86\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bc7\u0bb7\u0ba9\u0bcd \u0bb5\u0bca\u0bb0\u0bcd\u0b95\u0bcd\u0bb8\u0bcd) \u0b9a\u0bc0\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0bbe\u0bb0\u0bae\u0bcd\u0baa\u0bb0\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b85\u0ba4\u0ba9\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb0\u0baf\u0bbf\u0bb2\u0bcd\u0bb5\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0bb4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b87\u0bb0\u0baf\u0bbf\u0bb2\u0bcd\u0bb5\u0bc7 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd (TB\/T \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0b9a\u0bc0\u0ba9 \u0b85\u0bb0\u0b9a\u0bc1 \u0bb5\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b9a\u0bcd \u0b9a\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb2\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bae\u0bcd (Tier-1-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 30%, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc0\u0ba9\u0bbe\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd 20%)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0b95\u0b9a\u0bcd \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc0\u0ba9\u0bbe\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc7 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8)<\/li>\n\n\n\n<li>\u0b86\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>\u0b9a\u0bc0\u0ba9 \u0b87\u0bb0\u0baf\u0bbf\u0bb2\u0bcd\u0bb5\u0bc7 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bb8\u0bcd\u0b9f\u0bc7\u0b9f\u0bcd \u0b95\u0bbf\u0bb0\u0bbf\u0b9f\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bbe\u0bb0\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b87\u0bb4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"9.-hubbell-usa\">9. \u0bb9\u0baa\u0bcd\u0baa\u0bb2\u0bcd (\u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: \u0b8e\u0bb8\u0bcd.\u0b9a\u0bbf.\u0b9a\u0bbf (\u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bbe\u0bb0\u0bb0\u0bcd\u0b95\u0bb3\u0bcd)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 2.4\u201315 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 250,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 5,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0bb9\u0baa\u0bcd\u0baa\u0bb2\u0bcd, \u0b85\u0baa\u0bbe\u0baf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 (\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 I \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 2) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bb5\u0b9f \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bb5\u0bbf\u0ba9\u0bcd \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95 \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0baa\u0bbe\u0baf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 UL \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd (\u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0bb0\u0bbf\u0bb5\u0bbe\u0baf\u0bc1, \u0b87\u0bb0\u0b9a\u0bbe\u0baf\u0ba9 \u0b86\u0bb2\u0bc8\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bb5\u0bc8 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf (\u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0bb2 \u0b85\u0bb5\u0b95\u0bbe\u0b9a\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bc1\u0bb1\u0bc8 \u0b89\u0bb1\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8<\/li>\n\n\n\n<li>\u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bb3\u0bb5\u0bbf\u0bb2\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba8\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0b86\u0b9a\u0bbf\u0baf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1<\/li>\n\n\n\n<li>\u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bb0\u0bcd\u0bb5\u0ba4\u0bc7\u0b9a\u0b95\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9 \u0b87\u0b9f\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd, MSHA-\u0b86\u0bb2\u0bcd \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0baa\u0bc8 \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"10.-toshiba-japan\">10. \u0ba4\u0bcb\u0bb7\u0bbf\u0baa\u0bbe (\u0b9c\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd)<\/h3>\n\n\n\n<p><strong>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: \u0bb5\u0bbf.\u0b95\u0bc7 (\u0baa\u0bbe\u0bb0\u0bae\u0bcd\u0baa\u0bb0\u0bbf\u0baf\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd, \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf)<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 7.2\u201324 kV<br><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8<\/strong>: 300,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<br><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 (AC-4)<\/strong>: 6,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>\u0ba4\u0bcb\u0bb7\u0bbf\u0baa\u0bbe 2018-\u0bb2\u0bcd VCB \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd GIS \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bbf\u0baf\u0ba4\u0bc1. \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f VK \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bc1\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bbe\u0bae\u0bcd \u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd LS \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd OEM) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9c\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0baf \u0ba4\u0bb0\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bb4\u0bcd (\u0baa\u0bbe\u0bb0\u0bae\u0bcd\u0baa\u0bb0\u0bbf\u0baf\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9\u0bb5\u0bc8)<\/li>\n\n\n\n<li>\u0ba4\u0bcb\u0bb7\u0bbf\u0baa\u0bbe \u0b9c\u0bbf\u0b90\u0b8e\u0bb8\u0bcd\/\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0b9c\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bb3\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/li>\n\n\n\n<li>\u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0ba8\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0ba4\u0bcb\u0bb7\u0bbf\u0baa\u0bbe \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, \u0b9c\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0baf \u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0ba8\u0bcd\u0ba4\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02.webp\" alt=\"\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0bb5\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\" class=\"wp-image-2389\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2025\/12\/manufacturer-comparison-matrix-table-fig-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd-02: 10 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1, AC-4 \u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd, \u0bb5\u0bbf\u0bb2\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0ba3\u0bbf\u0bb5\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-decision-matrix\">\u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0b85\u0ba3\u0bbf\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n\n\n\n<p><strong>\u0b85\u0bb5\u0b9a\u0bbf\u0baf \u0b9a\u0bc7\u0bb5\u0bc8 (\u0b85\u0ba3\u0bc1, \u0b95\u0b9f\u0bb2\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0bb0\u0bbf\u0bb5\u0bbe\u0baf\u0bc1)<\/strong><br>\u2192 \u0b8f\u0baa\u0bbf\u0baa\u0bbf, \u0bb7\u0bcd\u0ba9\u0bc0\u0b9f\u0bb0\u0bcd, \u0b88\u0b9f\u0ba9\u0bcd<br>\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8: \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b9a\u0bc7\u0bb5\u0bc8, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd<br>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd: 30\u201340% \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd<\/p>\n\n\n\n<p><strong>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf (\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0bae\u0bcd, \u0ba8\u0bc0\u0bb0\u0bcd, HVAC)<\/strong><br>\u2192 \u0b8e\u0b95\u0bcd\u0bb8\u0bcd\u0baa\u0bbf\u0b86\u0bb0\u0bcd\u0b87\u0b8e\u0bb2\u0bcd\u0b87, \u0b8e\u0bb2\u0bcd\u0b8e\u0bb8\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd, \u0b9a\u0bc0\u0bae\u0bc6\u0ba9\u0bcd\u0bb8\u0bcd<br>\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8: \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\/\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8, IEC \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0baf\u0ba9\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<br>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bb1\u0bbf\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bbe\u0bb2\u0bae\u0bcd<\/p>\n\n\n\n<p><strong>OEM \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bc1)<\/strong><br>\u2192 \u0b8e\u0b95\u0bcd\u0bb8\u0bcd\u0baa\u0bbf\u0b86\u0bb0\u0bcd\u0b87\u0b8e\u0bb2\u0bcd\u0b87, \u0ba4\u0bc8\u0b95\u0bc8, \u0ba8\u0ba9\u0bcd\u0b9c\u0bbf\u0b99\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd<br>\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8: \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bb5\u0bbf\u0bb2\u0bc8, \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd, \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc6\u0b95\u0bbf\u0bb4\u0bcd\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8<br>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd: \u0b9a\u0bc1\u0baf\u0bae\u0bbe\u0b95 \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/p>\n\n\n\n<p><strong>\u0ba8\u0bbf\u0ba4\u0bbf \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \/ \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bb1\u0bcd\u0bb1<\/strong><br>\u2192 \u0ba4\u0bc8\u0b95\u0bc8, \u0bb9\u0baa\u0bcd\u0baa\u0bb2\u0bcd (\u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<br>\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8: \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1<br>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8: \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0ba4\u0bb0\u0bb5\u0bc1<\/p>\n\n\n\n<p>200-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd, \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4 \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd (\u0b8e.\u0b95\u0bbe., \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bc2\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0baf\u0bbf\u0bb2\u0bcd Tier-3 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd) \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 40% \u0bb5\u0bb0\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vacuum-vs-air-contactor-mining-safety-jcz-upgrade-benefits\/\">\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bbe?<\/a>, \u0b95\u0bb3\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb0\u0bc2\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-procurement-mistakes\">\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b95\u0bca\u0bb3\u0bcd\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0ba4\u0bb5\u0bb1\u0bc1 #1: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb2\u0bc8 \u0bb5\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<p>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\/\u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u201c12 kV, 400 A, AC-4 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u201d \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 RFQ, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8f\u0bb2\u0bae\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0baa\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 300,000-\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8, 1,000,000-\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f 40% \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0bc1 3.3\u00d7 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd: IEC 62271-106 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 M1-\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa \u2265500,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\u201d<\/li>\n\n\n\n<li>\u201c\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 AC-4: 400 A-\u0bb5\u0bbf\u0bb2\u0bcd \u22656,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba4\u0bb5\u0bb1\u0bc1 #2: \u0b9a\u0bc7\u0bb5\u0bc8 \u0b89\u0ba4\u0bbf\u0bb0\u0bbf\u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bc1\u0bb1\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/strong><\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0b90\u0bb0\u0bcb\u0baa\u0bcd\u0baa\u0bbf\u0baf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 40 \u0bb5\u0bbe\u0bb0 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0bb2\u0bae\u0bcd, \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0ba4\u0bbf\u0bb0\u0bbf\u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b95\u0bc8\u0baf\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 4 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>: \u0b9a\u0bc7\u0bb5\u0bc8 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u201c\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 VI \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b86\u0bb0\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u201d<\/li>\n\n\n\n<li>\u201c\u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 500 \u0b95\u0bbf.\u0bae\u0bc0.\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0baa\u0bbf\u0bb0\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0baf \u0b9a\u0bc7\u0bb5\u0bc8 \u0bae\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.\u201d<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba4\u0bb5\u0bb1\u0bc1 #3: \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc8 \u0ba8\u0b95\u0bb2\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1<\/strong><\/p>\n\n\n\n<p>\u201c\u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd X ABB-\u0b90\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd, \u0b8e\u0ba9\u0bb5\u0bc7 \u0ba8\u0bbe\u0bae\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bcb\u0bae\u0bcd\u201d \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb1\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bc8\u0b95\u0bcd\u0b95\u0bc1 50 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0bc8\u0baf\u0ba4\u0bc1 300 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0b87\u0ba4\u0bc1 \u0baa\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd Tier-2-\u0b90\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd Tier-1-\u0b90 \u0ba8\u0bbf\u0baf\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>: \u0b95\u0b9f\u0bae\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0b9f: \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd\/\u0ba8\u0bbe\u0bb3\u0bcd \u00d7 365<\/li>\n\n\n\n<li>\u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: (\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u00d7 \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, 15\u201325 \u0bb5\u0bb0\u0bc1\u0b9f \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd, \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1, \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (ABB, Schneider, Eaton) 30\u201340% \u0baa\u0bbf\u0bb0\u0bc0\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b86\u0ba4\u0bb0\u0bb5\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 OEM \u0ba8\u0bbf\u0baa\u0bc1\u0ba3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (XBRELE, LS Electric) \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc8\u0b9a\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd. \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (Taikai, Nanjing) \u0b85\u0ba4\u0bbf\u0b95 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0bb5\u0bb0\u0bb5\u0bc1 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bcd, \u0bb5\u0bc7\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b89\u0bb0\u0bbf\u0bae\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1\u2014\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2. 7 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf $2,000 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, 15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd $3,500 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0bb5\u0bbf\u0b9f 25 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd, \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bbe\u0bae\u0bb2\u0bc7\u0baf\u0bc7 \u0b87\u0ba4\u0bc1 \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc7\u0bb1\u0bcd\u0baa \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bb0 \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0baf\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b85\u0ba4\u0bc7 \u0b9a\u0bae\u0baf\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1, \u0b85\u0bb5\u0bcd\u0bb5\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb2\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bbf\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 Tier-3-\u0b90\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1\u0bae\u0bcd, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd Tier-1-\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8 \u0b95\u0bca\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd\u2014\u0b87\u0bb5\u0bc8 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc0\u0ba3\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0ba4\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vacuum-contactor-manufacturers\">\u0baa\u0bbf\u0bb1\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf: \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: \u0b9f\u0baf\u0bb0\u0bcd-1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong><\/p>\n\n\n\n<p>\u0b9f\u0baf\u0bb0\u0bcd-1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (ABB, Schneider, Eaton) \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 1,000,000 \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, 8,000\u201312,000 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 AC-4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, \u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 (KEMA, CPRI) \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 48 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0ba4\u0bbf\u0bb0\u0bbf\u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb2\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd. \u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, XBRELE (1M \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd, 8,000 AC-4, IEC-\u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f) \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 OEM \u0ba8\u0bbf\u0baa\u0bc1\u0ba3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 (30\u201350% \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1) \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bbf, \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0b9a\u0baa\u0bcd\u0bb3\u0bc8\u0baf\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (300,000 \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd, 4,000 AC-4) \u0bb5\u0bb0\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0ba9\u0bb0\u0bcd, \u0b87\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bcd 50\u201360% \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba4\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9\u0bb0\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1\u2014\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0ba3\u0bbf \u0b9a\u0bc0\u0ba9 OEM-\u0b95\u0bb3\u0bcd \u0b87\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0bb5\u0bbf\u0bb1\u0bcd\u0baa\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0b9a\u0bbf\u0baf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b88\u0b9f\u0bc1\u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0b92\u0bb0\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>IEC 62271-106-\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0b99\u0bcd\u0b95, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bb5\u0bc1\u0bae\u0bcd, \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0b95\u0bcd\u0b95 \u0b85\u0bb1\u0bbf\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2. \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd: (1) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bc6\u0baf\u0bb0\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bbe\u0bb0\u0bae\u0bcd (KEMA, CESI, CPRI, NEMA-\u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bbe\u0bb0\u0bae\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1), (2) \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8, (3) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bcd (\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0b95\u0b9f\u0bae\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf), (4) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0ba4\u0bbf (10 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0ba4\u0bbf\u0baa\u0bb2\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd). \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bbe\u0bb3\u0bb0\u0bcd \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0bb0\u0bbf\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 (FAT) \u0b95\u0bcb\u0bb0\u0bb5\u0bc1\u0bae\u0bcd. \u0b9a\u0bc1\u0baf\u0bbe\u0ba4\u0bc0\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b89\u0bb0\u0bbf\u0bae\u0bc8 \u0b95\u0bcb\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0baf\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd 40% \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc73: \u0b92\u0bb0\u0bc7 \u0baa\u0bc7\u0ba9\u0bb2\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b95\u0bb2\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bbe?<\/strong><\/p>\n\n\n\n<p>\u0b86\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0bb5\u0bbf\u0bb7\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd: (1)&nbsp;<strong>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8<\/strong>\u2014\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bae\u0bcd\u0baa\u0bbf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8 (110 VDC, 220 VAC, \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bc1\u0b95\u0bb0\u0bcd\u0bb5\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd; (2)&nbsp;<strong>\u0baa\u0bcc\u0ba4\u0bc0\u0b95\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>\u2014\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0bb3\u0bc8 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba4\u0bb3\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; (3)&nbsp;<strong>\u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u2014\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1 (NO\/NC) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; 15 A \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd 10 A \u0ba4\u0bc1\u0ba3\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b92\u0bb0\u0bc7 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b89\u0ba4\u0bbf\u0bb0\u0bbf\u0baa\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb2\u0bcd\u0bb2\u0bc1\u0ba8\u0bb0\u0bcd \u0baa\u0baf\u0bbf\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b8e\u0bb3\u0bbf\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd 500+ \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bbe\u0b95\u0ba9\u0b95\u0bcd \u0b95\u0bc1\u0bb4\u0bc1\u0bae\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0bb2\u0bcd \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 15\u201320% \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc74: \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0b9f\u0bae\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><\/p>\n\n\n\n<p>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bc1: (1)&nbsp;<strong>\u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(IEC 62271-106 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bae\u0bbe\u0ba9\u0ba4\u0bc1) \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\/\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bcd\u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1; (2)&nbsp;<strong>\u0b95\u0bc8\u0baf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0b9f\u0bb5\u0bc1<\/strong>&nbsp;\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd; (3)&nbsp;<strong>\u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(CAD \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1) \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd; (4)&nbsp;<strong>\u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/strong>&nbsp;\u0baa\u0bbe\u0b95 \u0b8e\u0ba3\u0bcd\u0b95\u0bb3\u0bcd, \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b86\u0bb0\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: (5)&nbsp;<strong>\u0b95\u0bca\u0bb4\u0bc1\u0baa\u0bcd\u0baa\u0bc1\/\u0b95\u0bca\u0bb4\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bbf\u0bb2 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/strong>, (6)&nbsp;<strong>\u0ba4\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(ISO 9001 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd, \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd), (7)&nbsp;<strong>\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd<\/strong>&nbsp;\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd (CuCr \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bb2\u0bb5\u0bc8 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1) \u0aae\u0abe\u0a9f\u0ac7. \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b8f\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u201c\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b87\u0ba3\u0b95\u0bcd\u0b95 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bb5\u0bc8\u201d.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc75: \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0bb5\u0bbf\u0bb2\u0bc8 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><\/p>\n\n\n\n<p>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 12 kV, 400 A, AC-4 \u0bb5\u0bbf\u0bb2\u0bc8 (2025): \u0b9f\u0baf\u0bb0\u0bcd-1 \u0baa\u0bbf\u0bb0\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (ABB, Schneider) \u0b92\u0bb0\u0bc1 \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 $3,500\u2013$5,000; \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 OEM-\u0b95\u0bb3\u0bcd (XBRELE, LS Electric) $2,000\u2013$3,000; \u0b9a\u0bc0\u0ba9 \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0ba8\u0bb0\u0bcd\u0b95\u0bb3\u0bcd $1,200\u2013$2,000. \u0bb5\u0bbf\u0bb2\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (12 kV \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 24 kV-\u0b95\u0bcd\u0b95\u0bc1 1.5\u20131.8\u00d7 \u0b9a\u0bc6\u0bb2\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd), \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 (400 A \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 630 A-\u0b95\u0bcd\u0b95\u0bc1 1.3\u20131.5\u00d7 \u0b9a\u0bc6\u0bb2\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bc1 vs \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1: +20\u201330%, \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1-\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb1\u0bc8: +50\u201380%) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b85\u0bb3\u0bb5\u0bc1 \u0ba4\u0bb3\u0bcd\u0bb3\u0bc1\u0baa\u0b9f\u0bbf\u0b95\u0bb3\u0bcd: 5+ \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 10\u201315%, 20+ \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 20\u201325%. 20 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbe\u0bb2 \u0b89\u0bb0\u0bbf\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0bca\u0ba4\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0bb2\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 VI-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd 6,000\u201310,000 AC-4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd, $800\u2013$1,500 \u0b9a\u0bc6\u0bb2\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd), \u0b9a\u0bc6\u0baf\u0bb2\u0bb1\u0bcd\u0bb1 \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u2014\u0b87\u0ba4\u0bc1 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0b95\u0bca\u0bb3\u0bcd\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd 2\u20133 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc76: \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba8\u0bcd\u0ba4 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bcd?<\/strong><\/p>\n\n\n\n<p>\u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd IP54 \u0b89\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1, \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf\u0baa\u0bcd \u0baa\u0b9f\u0bbf\u0bb5\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd, IEC 60068-2-6 \u0baa\u0b9f\u0bbf \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd (ATEX Ex d \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc0\u0ba9 MA \u0b95\u0bc1\u0bb1\u0bbf\u0baf\u0bc0\u0b9f\u0bc1) \u0ba4\u0bc7\u0bb5\u0bc8. \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bb5\u0bc8:&nbsp;<strong>\u0b8e\u0b95\u0bcd\u0bb8\u0bcd.\u0baa\u0bbf.\u0b86\u0bb0\u0bcd.\u0b87.\u0b8e\u0bb2\u0bcd.\u0b87<\/strong>&nbsp;(MA \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf JCZ \u0ba4\u0bca\u0b9f\u0bb0\u0bcd, 200-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f),&nbsp;<strong>\u0b8f\u0baa\u0bbf\u0baa\u0bbf<\/strong>&nbsp;(IP65 \u0bb5\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc2\u0b95\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf VM1),&nbsp;<strong>\u0b88\u0b9f\u0bcd\u0b9f\u0ba9\u0bcd<\/strong>&nbsp;(\u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf VCP-W). \u0b8e\u0bb2\u0bcd\u0b8e\u0bb8\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbf\u0b95\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb7\u0bcd\u0ba9\u0bc0\u0b9f\u0bb0\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0bae\u0bc6\u0bb0\u0bbf\u0b95\u0bcd\u0b95 MSHA \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc0\u0ba9 MA \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0b85\u0bb5\u0bc8 \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba9. \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc0\u0bb2\u0bbf\u0b99\u0bcd \u0ba4\u0bc2\u0b9a\u0bbf \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0ba8\u0bc1\u0bb4\u0bc8\u0baf \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba8\u0bbf\u0bb2\u0b95\u0bcd\u0b95\u0bb0\u0bbf \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95 \u0b95\u0bb3 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 18\u201336 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc77: \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0bb5\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: (1) \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 (\u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd) \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0baa\u0ba3\u0bbf \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd; (2) \u0b85\u0ba3\u0bc1\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd\u2014500 \u00b5\u03a9-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; (3) \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bae\u0bcd \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b8e\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0bb5\u0bc6\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0b99\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd); (4) \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0bb2\u0b95\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0b85\u0ba4\u0bc8 \u0b85\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd). 48 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b86\u0ba4\u0bb0\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bbe\u0ba9 \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0b85\u0bb1\u0bbf\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 1 \u0bb5\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4 \u0b86\u0baf\u0bcd\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0b95\u0bb3\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd. \u0b9a\u0bc0\u0ba9 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1 \u0b95\u0bcb\u0bb0\u0bb2\u0bbe\u0bae\u0bcd (4\u20138 \u0bb5\u0bbe\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8), \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b87\u0ba4\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>","protected":false},"excerpt":{"rendered":"<p>\ufeff Selecting a vacuum contactor manufacturer is not a commodity decision. Two contactors rated 12 kV, 400 A, AC-4 can differ by a factor of three in mechanical life, exhibit contact erosion rates varying 40%, and ship with documentation quality ranging from \u201ccomplete type-test certificates\u201d to \u201ctrust us, it works.\u201d These differences surface 18 months [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2388,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25,28],"tags":[],"class_list":["post-2386","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge","category-industry-news"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2386"}],"version-history":[{"count":6,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2386\/revisions"}],"predecessor-version":[{"id":3851,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2386\/revisions\/3851"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2388"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2386"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2386"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2386"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}