{"id":2392,"date":"2026-01-02T08:14:43","date_gmt":"2026-01-02T08:14:43","guid":{"rendered":"https:\/\/xbrele.com\/?p=2392"},"modified":"2026-04-07T13:47:09","modified_gmt":"2026-04-07T13:47:09","slug":"capacitor-bank-switching-inrush-pre-insertion","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/capacitor-bank-switching-inrush-pre-insertion\/","title":{"rendered":"\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0baf\u0bcd\u0ba9\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd: \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1, \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0ba4\u0bb2\u0bcd, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1"},"content":{"rendered":"<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1, \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0b85\u0bb0\u0bc8-\u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 20-100 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd 5-10 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bc1\u0bae\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1, \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 AC-3 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 AC-4 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bb5\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b95\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b86\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bc7\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd \u0baa\u0bb5\u0bb0\u0bcd \u0b83\u0baa\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0baa\u0bb2\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0b9f\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 12 kV, 5 MVAR \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd, 240 A \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b88\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, 12 kA \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0b9f\u0bcd\u0b9f \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 (\u0b85\u0ba4\u0bbe\u0bb5\u0ba4\u0bc1 \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 50 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1) \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0b9f\u0bc8\u0baf\u0bc2\u0bb1\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd (vacuum interrupter contacts) \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd (upstream protection devices) \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8\u0baf\u0bc6\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf (contactor) \u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0bbf\u0b99\u0bcd \u0b86\u0b95\u0bbf \u0bae\u0bc2\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bb1\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc1 \u0b86\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bc7\u0bb7\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0ba9\u0bcd \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc7 \u0ba4\u0bcb\u0bb1\u0bcd\u0b95\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd, \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb0\u0bbf \u0b85\u0bb3\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 (AC-6b) \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0baf\u0bcd\u0ba9\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd: \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/lkBZRcl1j2g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-capacitor-inrush-exceeds-motor-starting-current\">\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0baf\u0bcd\u0ba9\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0bb8\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b9f\u0bbf\u0b99\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd<\/h2>\n\n\n\n<p>\u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd, \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc6\u0b9f\u0ba9\u0bcd\u0bb8\u0bbe\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bb8\u0bcd\u0b95\u0bc1\u0baf\u0bb0\u0bcd\u0bb2\u0bcd-\u0b95\u0bc7\u0b9c\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1-\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 6-8 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b95\u0bc7\u0baa\u0bcd\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd, \u0b95\u0bc7\u0baa\u0bcd\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc2\u0bb2 \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc6\u0b9f\u0ba9\u0bcd\u0bb8\u0bbe\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0bb5\u0bbf\u0baf\u0bc2\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, \u0b9f\u0bbf\u0bb8\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0ba4\u0ba9\u0bcd \u0baa\u0bbf\u0bb3\u0bc7\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8, \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba8\u0bcd\u0ba4 \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b92\u0bb0\u0bc1 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bcb\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd. \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2 \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd (\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd, \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd, \u0baa\u0bb8\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd) \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0b9f\u0bcd\u0b9f \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n\n\n\n<p><strong>\u0b89\u0b9a\u0bcd\u0b9a \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0b85\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd)<\/strong>:<br>I<sub>\u0b9a\u0bbf\u0b95\u0bb0\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95<\/sub>\u00a0= V<sub>\u0bae\u0bc1\u0bb1\u0bc8\u0bae\u0bc8<\/sub>\u00a0\/ (Z<sub>\u0bae\u0bc2\u0bb2\u0bae\u0bcd<\/sub>\u00a0+ Z<sub>\u0b95\u0bae\u0bcd\u0baa\u0bbf<\/sub>)<br>0.5 \u03a9 \u0bae\u0bc2\u0bb2\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f 12 kV \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1:<br>I<sub>\u0b9a\u0bbf\u0b95\u0bb0\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95<\/sub>\u00a0= (12,000 V \u00d7 \u221a2) \/ 0.5 \u03a9 \u2248\u00a0<strong>34 kA<\/strong><\/p>\n\n\n\n<p>\u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bbf\u0ba9\u0bcd \u0b87\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b89\u0b9a\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd (8-15 kA) \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b86\u0ba9\u0bbe\u0bb2\u0bcd, 10 kA \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 40-50 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd\u2014\u0b87\u0ba4\u0bc1 6-8 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd AC-4 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95 \u0bb5\u0b95\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b85\u0bb2\u0bc8\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong>&nbsp;\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bbf\u0bb2\u0bcd (50\/60 Hz) \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0b9f\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 LC \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0baf\u0bb0\u0bcd-\u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 (500 Hz \u2013 5 kHz) \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b89\u0baf\u0bb0\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/how-does-a-vacuum-contactor-extinguish-arc-inside-the-vacuum-interrupter\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bb3\u0bc8\u0b95\u0bb3\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/a>&nbsp;\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b95\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0ba9\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0ba9\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bc2\u0bb0\u0bae\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0b87\u0ba4\u0bc1 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01.webp\" alt=\"\u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd 6\u00d7 \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd 40\u00d7 \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0baf\u0bb0\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b86\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bcb\u0baa\u0bcd \u0ba4\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd\" class=\"wp-image-2396\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/motor-vs-capacitor-inrush-oscilloscope-comparison-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 1. \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bcb\u0baa\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1: \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (\u0bae\u0bc7\u0bb2\u0bcd) 200 ms-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 6\u00d7 \u0b89\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (\u0b95\u0bc0\u0bb4\u0bcd) 1 kHz \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0bae\u0b99\u0bcd\u0b95\u0bb2\u0bc1\u0b9f\u0ba9\u0bcd 40\u00d7 \u0b89\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 AC-6b \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"utilization-category-ac-6b-what-makes-it-different\">\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8 AC-6b: \u0b87\u0ba4\u0bc8 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b8e\u0ba4\u0bc1<\/h2>\n\n\n\n<p>IEC 62271-106, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b95\u0b9f\u0bae\u0bc8 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. AC-4, \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 (\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, 6-8\u00d7 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd) \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1.&nbsp;<strong>\u0b8f\u0b9a\u0bbf-6\u0baa\u0bbf<\/strong>&nbsp;\u0ba4\u0ba9\u0ba4\u0bc1 \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd, \u0b87\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf AC-6b \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong>: \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba8\u0bc6\u0bb0\u0bbf\u0b9a\u0bb2\u0bc8 (\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f 40-100 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b89\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/strong>\u0ba4\u0b9f\u0bc8\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba8\u0bcd\u0ba4\u0bb5\u0bca\u0bb0\u0bc1 \u0b92\u0bb2\u0bbf\u0bae\u0bcd\u0baa\u0b9f\u0bbf \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0bb0\u0bc6\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bc8\u0b95\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bbf<\/strong>: \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc2\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; TRV (\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd) \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 1.4 p.u. \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 2.0 p.u. \u0bb5\u0bb0\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bb2\u0bbe\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p>120 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bae\u0bc8 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95, \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 AC-4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd 500-2,000 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1 \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bb5\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1. CuCr25 \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0baf\u0bc8\u0baa\u0bcd (\u0b85\u0ba4\u0bbf\u0b95 \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd AC-6b \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 10,000-30,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf<\/strong>&nbsp;AC-6b \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd: AC-4-\u0b95\u0bcd\u0b95\u0bbe\u0ba9 8-10 \u0bae\u0bbf\u0bae\u0bc0 \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 12-14 \u0bae\u0bbf\u0bae\u0bc0. \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bc1\u0ba9\u0bcd-\u0b86\u0bb0\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0ba4\u0bc2\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0bb0\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b89\u0b9a\u0bcd\u0b9a \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bcb\u0bb2 \u0bae\u0bbf\u0ba9\u0bcdcondensator-\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<\/p>\n\n\n\n<p><strong>AC-6b \u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd (IEC 62271-106-\u0b87\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>:<br>\u2022 12 kV, 200 A \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0ba3\u0bbf:\u00a0<strong>10,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong><br>\u2022 12 kV, 400 A \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0ba3\u0bbf:\u00a0<strong>8,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong><br>\u2022 24 kV, 200 A \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0ba3\u0bbf:\u00a0<strong>6,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/strong><br>AC-4 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0b9f\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1: \u0b85\u0ba4\u0bc7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 10,000-15,000 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<p>\u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/capacitor-duty-contactor-failure-modes-switching\/\">\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0b95\u0b9f\u0bae\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/a>, \u0b9f\u0bc0\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0bb5\u0b9f\u0bbf\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0bb5\u0bc8.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"pre-insertion-resistors-physics-and-sizing\">\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd: \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bae\u0bcd<\/h2>\n\n\n\n<p>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. 10-50 ms (\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd) \u0b95\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 \u0baa\u0bc8\u0baa\u0bbe\u0bb8\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bc8 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1, \u0b85\u0ba4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bbf\u0bb2\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li>R-\u0b86\u0bb2\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd: I = V \/ (Z_source + R)<\/li>\n\n\n\n<li>\u0ba4\u0bbe\u0bae\u0ba4 \u0bb0\u0bbf\u0bb2\u0bc7 10-50 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b95\u0ba3\u0bcd\u0b9f\u0ba9\u0bcd\u0bb8\u0bb0\u0bcd ~95% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bcd \u0b86\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0baa\u0bbe\u0baf\u0bcd\u0baa\u0bbe\u0bb8\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd\u0b9f\u0bbf\u0b99\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd<\/li>\n\n\n\n<li>\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0baa\u0bcd\u0baa\u0ba4\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bc2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bae\u0bcd<\/strong>:<br>R = (V<sub>\u0b9a\u0bbf\u0b95\u0bb0\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95<\/sub>&nbsp;\u2013 \u0bb5\u0bbf<sub>\u0ba4\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0bc1,\u0b86\u0bb0\u0bae\u0bcd\u0baa\u0bae\u0bcd<\/sub>) \/ \u0ba8\u0bbe\u0ba9\u0bcd<sub>\u0b95\u0bc1\u0bb4\u0bc1\u0bae\u0bae\u0bcd,\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd<\/sub><br>12 kV \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 2 kA \u0b86\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd:<br>R = (16,970 V \u2013 0 V) \/ 2,000 A \u2248&nbsp;<strong>8.5 \u0b93\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b9a\u0bbf\u0ba4\u0bb1\u0bb2\u0bcd (\u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b95\u0bbe\u0bb2 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1)<\/strong>:<br>\u0baa\u0bbf = \u0b90\u00b2 \u00d7 \u0b86\u0bb0\u0bcd \u00d7 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd<br>2 kA \u0b89\u0bb3\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, 20 ms \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1:<br>\u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd = (2,000)\u00b2 \u00d7 8.5 \u00d7 0.020 =\u00a0<strong>680 \u0b95\u0bbf\u0bb2\u0bcb\u0b9c\u0bcc\u0bb2\u0bcd<\/strong><br>\u0b85\u0ba4\u0bbf\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd (\u0bb5\u0baf\u0bb0\u0bcd\u0bb5\u0bc8\u0ba3\u0bcd\u0b9f\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbf\u0bb0\u0bbf\u0b9f\u0bcd \u0bb5\u0b95\u0bc8) \u0ba4\u0bc7\u0bb5\u0bc8.<\/p>\n\n\n\n<p><strong>\u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb5\u0bbe\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb0\u0b9f\u0bcd\u0b9f\u0bbf \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0bae\u0bcd \u2192 20 \u0bae\u0bbf.\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 300\u00b0C).<\/li>\n\n\n\n<li>\u0baa\u0bc8\u0baa\u0bbe\u0bb8\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd 10-50 ms \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95, \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbe\u0b95 (\u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b86\u0b95\u0bbe\u0bae\u0bb2\u0bcd) \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p>80-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0baa\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8 60-70% \u0bb5\u0bb0\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 3,000-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 12,000-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02.webp\" alt=\"\u0ba8\u0bc7\u0bb0\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd, \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0baa\u0bc8\u0baa\u0bbe\u0bb8\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd-\u0bae\u0bc1\u0ba9\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" class=\"wp-image-2395\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/pre-insertion-resistor-circuit-diagram-capacitor-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 2. \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1, 34 kA (\u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd) \u0b8e\u0ba9\u0bcd\u0bb1 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8 2 kA (\u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1) \u0b8e\u0ba9\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 8.5\u03a9 \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; 20 ms \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1, \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0baa\u0bc8\u0baa\u0bbe\u0bb8\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bc8 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"back-to-back-switching-and-resonance-risk\">\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd<\/h2>\n\n\n\n<p>\u0baa\u0bb2 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0c97\u0cb3\u0cc1 \u0b92\u0bb0\u0bc7 \u0baa\u0bc7\u0bb8\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u201c\u0baa\u0bbf\u0ba9\u0bcd-\u0baa\u0bbf\u0ba9\u0bcd\u201d \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0ba4\u0b9f\u0bc8 \u0b8f\u0b9a\u0bbf \u0bae\u0bc2\u0bb2\u0bae\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0baa\u0bc1\u0ba4\u0bbf\u0ba4\u0bbe\u0b95 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0bcd<\/strong>:<br>\u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 3 \u0bb5\u0b99\u0bcd\u0b95\u0bbf(\u0b95\u0bb3\u0bcd) (\u0bae\u0bca\u0ba4\u0bcd\u0ba4\u0bae\u0bcd 15 MVAR) \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, 4\u0bb5\u0ba4\u0bc1 \u0bb5\u0b99\u0bcd\u0b95\u0bbf (5 MVAR) \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<br>Z<sub>\u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3<\/sub>\u00a0= (\u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b87\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd) \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u2014 \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba4\u0bbf\u0bb1\u0bae\u0bcd\u0baa\u0b9f \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<br>\u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1: \u0b89\u0bb3\u0bcd\u0bb3\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd\u00a0<strong>100-200\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/strong>\u00a0\u0bae\u0bc1\u0ba4\u0bb2\u0bcd-\u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0bbf\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 vs 20-40\u00d7.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/strong>: 30-60 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd, \u0b92\u0bb0\u0bc1 \u0b9a\u0bae\u0baf\u0bae\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bbe\u0b95 \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bbf\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b95\u0bbe\u0bb2 \u0bae\u0bbe\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0b99\u0bcd\u0b95 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0b9f\u0bc0\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 (inductance) (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 5-7%) \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd, \u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3 \u0ba4\u0b9f\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf, \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 \u0bae\u0bc2\u0b9f\u0bb2\u0bcd<\/strong>\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p>40 \u0baa\u0bb2-\u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b9f\u0bbf\u0b9f\u0bbf\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bc7\u0b95\u0bcd-\u0b9f\u0bc1-\u0baa\u0bc7\u0b95\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd\u0bb7\u0bc8 50-70% (150\u00d7-\u0b87\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 45-60\u00d7 \u0bb5\u0bb0\u0bc8) \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf PFC \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b87\u0b9a\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1<\/strong>&nbsp;\u0b95\u0bbf\u0bb0\u0bbf\u0b9f\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (5\u0bb5\u0ba4\u0bc1, 7\u0bb5\u0ba4\u0bc1, 11\u0bb5\u0ba4\u0bc1) \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bcd, \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd L \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd C-\u0b90 \u0b9f\u0bbf\u0baf\u0bc2\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b87\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0bb4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>5.67% \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, 4-\u0bb5\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 5-\u0bb5\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bbf\u0b95\u0bcd \u0b87\u0b9f\u0bc8\u0baf\u0bc7, \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bbf\u0ba9\u0bcd 4.2 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>7% \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, 5-\u0bb5\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd, \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bbf\u0ba9\u0bcd 3.8 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03.webp\" alt=\"\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0baa\u0bcd\u0baa\u0bc6\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0bb4\u0bbf \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd 40\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 200\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.\" class=\"wp-image-2394\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/back-to-back-capacitor-switching-inrush-vector-diagram-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 3. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd-\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bc2\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8: \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd (15 MVAR) \u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0bb1\u0bcd\u0bb1 \u0bae\u0bc2\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 0.5\u03a9-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (0.02\u03a9) \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 40\u00d7-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 200\u00d7-\u0b86\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-coordination-fuses-vs-relays\">\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1: \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bcd vs \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb1\u0bbf\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>\u00a0(20-100\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, 5-20 ms \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1) \u2014 \u0ba4\u0b9f\u0bc1\u0bae\u0bbe\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0baf\u0bcd\u0ba9\u0bb0\u0bcd \u0b89\u0bb3\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u00a0(\u0baa\u0bbf\u0bb3\u0bb5\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1) \u2014 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u00a0(\u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0b9f\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bbf) \u2014 \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\/\u0ba4\u0bb5\u0bb1\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>&nbsp;(5 MVAR-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9\u0ba4\u0bc1):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 1.5-2.0\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd I\u00b2t, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:\n<ul class=\"wp-block-list\">\n<li>Inrush I\u00b2t = (40 \u00d7 I_rated)\u00b2 \u00d7 0.010 s<\/li>\n\n\n\n<li>200 \u0b86 amp\u00e8re \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf: I\u00b2t = 64,000 A\u00b2s<\/li>\n\n\n\n<li>\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95, I\u00b2t &gt;100,000 A\u00b2s \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bb0\u0bbf\u0bb2\u0bc7 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>&nbsp;(&gt;5 MVAR \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2, 0.5-1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0bb2\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0b85\u0bb3\u0bb5\u0bc8 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 1.3-1.5\u00d7-\u0bb2\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0b9a\u0ba4\u0bbf\u0baf\u0bc8 (2\u0bb5\u0ba4\u0bc1\/3\u0bb5\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1) \u0b95\u0bbf\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p>\u0bae\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 4-6 \u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd 15-20 MVAR \u0b95\u0baa\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd-\u0baa\u0bbf\u0bb3\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc8 \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf \u0baa\u0bbf\u0bb1\u0b95\u0bc1, \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd 30% \u0b85\u0bb3\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0ba4\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 (SEL-751 \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7, 12 kV 5 MVAR \u0bb5\u0b99\u0bcd\u0b95\u0bbf, 240 A \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1)<\/strong>:<br><code>50P1 = \u0b85\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/code>\u00a0(\u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc8 \u0bae\u0bc1\u0b9f\u0b95\u0bcd\u0b95\u0bc1)<br><code>51P1 = 1.4 \u00d7 240 = 336 A<\/code>\u00a0(\u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd)<br><code>51TD1 = 1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf<\/code>\u00a0(\u0b85\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0bb2 \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd)<br><code>50H1 = 20%<\/code>\u00a0(\u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contactor-selection-checklist-for-capacitor-duty\">\u0b95\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1<\/h2>\n\n\n\n<p>\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95, \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba9 AC-6b \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u2014\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 AC-4 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<p><strong>1. AC-6b \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0ba3\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0ba3\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd IEC 62271-106 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (12 kV, 400 A, \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8).<\/li>\n\n\n\n<li>\u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf PFC-\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 8,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0bc1<\/strong><br>I<sub>\u0ba4\u0bbf\u0bb0\u0bbe\u0b95\u0b9f\u0bcd\u0b9f\u0bbf<\/sub>\u00a0= \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf<sub>\u0b8e\u0bae\u0bcd\u0bb5\u0bbf\u0b8f\u0b86\u0bb0\u0bcd<\/sub>\u00a0\/ (\u221a3 \u00d7 V<sub>\u0bb5\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bbf<\/sub>)<br>\u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: 12 kV-\u0bb2\u0bcd 5 MVAR<br>I = 5,000,000 \/ (1.732 \u00d7 12,000) =\u00a0<strong>240 \u0b8f<\/strong><br>\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u22651.35\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0bbf =\u00a0<strong>325 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<p><strong>3. \u0b89\u0bb3\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>AC-6b-\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b89\u0b9a\u0bcd\u0b9a \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 AC-6b \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd 40-60\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (&gt;60\u00d7 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1), \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>4. \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 NO\/NC \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 4 NO + 2 NC)<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (110 VDC, 220 VAC, \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8)<\/li>\n\n\n\n<li>\u0b89\u0ba4\u0bb5\u0bbf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: 100,000-300,000 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>5. \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0b9f\u0bcd\u0baa\u0bc1\u0bb1\u0bae\u0bcd: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd IP20; \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0bae\u0bcd: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd IP54<\/li>\n\n\n\n<li>1000 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b89\u0baf\u0bb0\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (\u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1: -25\u00b0C \u0bae\u0bc1\u0ba4\u0bb2\u0bcd +40\u00b0C \u0bb5\u0bb0\u0bc8 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0bb2\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/li>\n<\/ul>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b95\u0bb2\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcb\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/advantages-of-vacuum-contactor-reliable-safe-efficient-choice\/\">\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/a>&nbsp;AC-6b \u0baa\u0ba3\u0bbf\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf, \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd.&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/medium-voltage-vacuum-contactor-guide\/\">\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04.webp\" alt=\"AC-6b \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1, \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0b95\u0bcd-\u0b9f\u0bc1-\u0baa\u0bc7\u0b95\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b93\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2393\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/capacitor-vacuum-contactor-selection-flowchart-04-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 4. AC-6b \u0b9f\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bc7\u0b95\u0bcd-\u0b9f\u0bc1-\u0baa\u0bc7\u0b95\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1, \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbe\u0ba4\u0bbe\u0bb0\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0b9a\u0bae\u0bb0\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bcd\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b93\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bae\u0bcd.<\/figcaption><\/figure>\n\n\n\n<p><strong>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b8f\u0b9a\u0bbf \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bc6\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0baa\u0ba3\u0bbf \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 62271-106<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-and-end-of-life-indicators\">\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2 \u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95, \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd-\u0b9f\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf \u0b9a\u0bae\u0bae\u0bbe\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0b9f \u0b95\u0bc7\u0baa\u0bcd\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd-\u0b9f\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 2,000-3,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (AC-4-\u0b95\u0bcd\u0b95\u0bbe\u0ba9 5,000-\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd)<\/li>\n\n\n\n<li>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 500 \u00b5\u03a9-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 100-200 \u00b5\u03a9).<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b87\u0bb4\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0b9f\u0bbf\u0baf\u0baa\u0b9f\u0bbf\u0baf\u0bc7 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0b92\u0bb2\u0bbf \u0b8e\u0bb4\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0ba4\u0bc1\u0ba3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b95\u0ba3\u0bcd\u0b9f\u0ba9\u0bcd\u0b9a\u0bbf\u0baf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b86\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 &gt;10% \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p>\u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd 200 \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0b95\u0bb3 \u0b86\u0baf\u0bcd\u0bb5\u0bbf\u0bb2\u0bcd, \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f AC-6b \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 12,000-18,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0ba9, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f AC-4 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd 3,000-5,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba9. \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bc7\u0b95\u0bcd-\u0b9f\u0bc1-\u0baa\u0bc7\u0b95\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 20,000+ \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u201420-100\u00d7 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0baf\u0bb0\u0bcd-\u0b86\u0bb5\u0ba3\u0bcd\u0bae\u0bc8 \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0ba9\u0bcd-\u0b86\u0bb0\u0bcd\u0b95\u0bbf\u0b99\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd AC-6b \u0ba4\u0bb0\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b86\u0baf\u0bc1\u0bb3\u0bc8 8,000-15,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b87\u0ba4\u0bc1 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bcd 60\u00d7-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b89\u0b9a\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd-\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0baa\u0bb2-\u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9f\u0bbf\u0b9f\u0bbf\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0b9f\u0bcd\u0b9f\u0bc8 \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9: \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95, \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bb5\u0ba9\u0bae\u0bbe\u0ba9 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b95\u0bbe\u0bb2 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0ba9 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 4-6 \u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bbf \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b95\u0bbe\u0bb2 \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf-\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd-\u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0b8e\u0bb3\u0bbf\u0baf \u0b92\u0bb1\u0bcd\u0bb1\u0bc8-\u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8, \u0ba4\u0bb5\u0bb1\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd \u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0bbf\u0b99\u0bcd, \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1, \u0b95\u0baa\u0bcd\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bc8 \u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b87\u0ba4\u0bc1 \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bbf\u0bb5\u0bcd \u0baa\u0bb5\u0bb0\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd, \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-capacitor-bank-switching\">\u0baa\u0bbf\u0bb1\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf: \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 AC-4 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (AC-4) \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bbf\u0bb2\u0bcd (50\/60 Hz) 6-8\u00d7 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9. \u0b89\u0baf\u0bb0\u0bcd-\u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd (500 Hz \u2013 5 kHz) \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bbf, \u0b95\u0bc7\u0baa\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 20-100\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8e\u0b9f\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd, \u0b87\u0ba4\u0bc1 AC-4 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, AC-4 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd 500-2,000 \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd AC-6b \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd 8,000-15,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8, \u0ba4\u0bc1\u0bb0\u0bbf\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd\u2014AC-4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f CuCr15-20 \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd\u0b95\u0bb2\u0bb5\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd AC-6b, \u0b95\u0bc7\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b85\u0ba4\u0bbf\u0b95 \u0b95\u0bc1\u0bb0\u0bcb\u0bae\u0bbf\u0baf\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f CuCr25-\u0b90\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>R = V_peak \/ I_inrush_max \u0b8e\u0ba9\u0bcd\u0bb1 \u0b9a\u0bae\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bbf\u0bb2\u0bcd V_peak = \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u00d7 \u221a2 (12 kV-\u0b95\u0bcd\u0b95\u0bc1: 16,970 V) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd I_inrush_max \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 1.5-2.5 kA) \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: 12 kV \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc8 2 kA \u0b86\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4, R = 16,970 \/ 2,000 \u2248 8.5 \u03a9 \u0ba4\u0bc7\u0bb5\u0bc8. \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b95\u0bbe\u0bb2 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd: E = I\u00b2 \u00d7 R \u00d7 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd. 2 kA, 20 ms-\u0b95\u0bcd\u0b95\u0bc1: E = (2,000)\u00b2 \u00d7 8.5 \u00d7 0.020 = 680 kJ. \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bc1 (\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0bae\u0bcd \u2192 300\u00b0C \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd) \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0baf\u0bb0\u0bcd\u0bb5\u0bc8\u0ba3\u0bcd\u0b9f\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbf\u0bb0\u0bbf\u0b9f\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bb1\u0bcd\u0bb1 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95, \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0b85\u0b9f\u0bc8\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc73: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd, \u0b85\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc7 \u0baa\u0bb8\u0bcd\u0bb8\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bae\u0bb1\u0bcd\u0bb1 \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0baf\u0bc8 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd-\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd (Back-to-back switching) \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc6\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd \u0b8f\u0b9a\u0bbf \u0bae\u0bc2\u0bb2\u0bae\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bc2\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc6\u0b9f\u0bbe\u0ba9\u0bcd\u0bb8\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1, \u0baa\u0bc1\u0ba4\u0bbf\u0ba4\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd 100-200\u00d7 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 (inrush) \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 20-40\u00d7 \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1). \u0b8f\u0ba9\u0bc6\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd, \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b87\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd\u0bb8\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0b95\u0baa\u0bb8\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bbe\u0ba9\u0bcd\u0bb8\u0bc8 \u0ba4\u0bbf\u0bb1\u0bae\u0bcd\u0baa\u0b9f \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1: 30-60 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbe\u0bae\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bb8\u0bcd\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd, 5-7% \u0b9f\u0bc0\u0b9f\u0bbf\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd\u0bb8\u0bc8 50-70% \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b9c\u0bc0\u0bb0\u0bcb-\u0b95\u0bbf\u0bb0\u0bbe\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 \u0bae\u0bc2\u0b9f\u0bb2\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc74: \u0b95\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bbf\u0baf\u0ba9\u0bcd\u0b9f\u0bcd \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc8 \u0bb5\u0bbf\u0b9f (5-20 ms) \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95, \u0bae\u0bc7\u0bb2\u0bc7 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bbe\u0ba9 \u0b93\u0bb5\u0bb0\u0bcd\u0915\u0930\u0947\u0ba9\u0bcd\u0b9f\u0bcd\u0b9f\u0bc8 (0.5-1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1: \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95, \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd I\u00b2t-\u0b87\u0ba9\u0bcd 2 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd I\u00b2t \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1: 40\u00d7 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (8 kA \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd, 10 ms) \u0b95\u0bca\u0ba3\u0bcd\u0b9f 200 A \u0b95\u0bc6\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd I\u00b2t = 640,000 A\u00b2s; I\u00b2t &gt;1,200,000 A\u00b2s \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb8\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1: \u0b95\u0bbf\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc8 (2\u0bb5\u0ba4\u0bc1\/3\u0bb5\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1) \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8e\u0bb3\u0bbf\u0baf \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd-\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 30% \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9. \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b88\u0b9f\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 1.3-1.5\u00d7 \u0b87\u0bb2\u0bcd \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc75: \u0b9f\u0bc0\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcd\u0bb0\u0bc0-\u0b87\u0ba9\u0bcd\u0b9a\u0bc6\u0bb0\u0bcd\u0bb7\u0ba9\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong><\/p>\n\n\n\n<p>\u0b9f\u0bc0\u0baf\u0bc2\u0ba9\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (5-7% \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b87\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd) \u0ba8\u0bbf\u0bb0\u0ba8\u0bcd\u0ba4\u0bb0\u0bae\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9, \u0b85\u0bb5\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b85\u0bb5\u0bc8 \u0b87\u0bb0\u0b9f\u0bcd\u0b9f\u0bc8 \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9: (1) 5\u0bb5\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf, \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, (2) \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd 50-70%-\u0b90\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bae\u0bcd \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0bae\u0bbe\u0b95 (10-50 ms) \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bb5\u0ba4\u0bc1 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd 30-50\u00d7 \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 2-3\u00d7 \u0bb5\u0bb0\u0bc8 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bb5\u0bc8), \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bc8\u0baf\u0bc1\u0bae\u0bcd (\u0baa\u0baf\u0baa\u0bbe\u0bb8\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd, \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7) \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd; \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bc7\u0b95\u0bcd-\u0b9f\u0bc1-\u0baa\u0bc7\u0b95\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\/\u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc76: \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><\/p>\n\n\n\n<p>AC-6b \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 8,000-15,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 2,000-3,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd (\u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 5,000) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 500 \u00b5\u03a9-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0b9f\u0bbf\u0bae\u0ba9\u0bc8 &gt;30%-\u0b86\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd. \u0bae\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 6 \u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf PFC \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 2-4 \u0bb5\u0bb0\u0bc1\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd (8,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u00f7 6 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\/\u0bae\u0ba3\u0bbf \u00f7 8760 \u0bae\u0ba3\u0bbf\/\u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u2248 2.5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd). \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 20,000+ \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0bcd, \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u00b130% \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc77: \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 AC-6b \u0ba4\u0bb0\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0ba8\u0bbe\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/strong><\/p>\n\n\n\n<p>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8. AC-6b \u0baa\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd (CuCr25 vs CuCr15-20) \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf (12-14 \u0bae\u0bbf\u0bae\u0bc0 vs 8-10 \u0bae\u0bbf\u0bae\u0bc0), \u0bb5\u0bb2\u0bc1\u0bb5\u0bc2\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0bb1\u0bc8\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bbe\u0ba4\u0bc1\u2014\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf \u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b95\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 AC-6b \u0ba4\u0bb0\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd. AC-4 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd) \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd (\u0b85\u0ba4\u0bbf\u0b95 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0bc1) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bb3 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd 100% \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bcd 1,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 AC-6b \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc1 12,000+ \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9.<\/p>","protected":false},"excerpt":{"rendered":"<p>Switching capacitor banks with vacuum contactors creates the most severe transient conditions in medium-voltage motor control applications. Inrush current during energization reaches 20-100\u00d7 rated capacitor current in the first half-cycle, sustained for 5-10 ms before decaying. This transient exceeds the making capacity of standard AC-3 or AC-4 rated contactors, causing contact welding, excessive erosion, and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2398,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-2392","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2392"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2392\/revisions"}],"predecessor-version":[{"id":3568,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2392\/revisions\/3568"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2398"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2392"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2392"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2392"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}