{"id":2401,"date":"2026-01-02T08:47:36","date_gmt":"2026-01-02T08:47:36","guid":{"rendered":"https:\/\/xbrele.com\/?p=2401"},"modified":"2026-04-07T14:03:21","modified_gmt":"2026-04-07T14:03:21","slug":"vcb-commissioning-checklist-timing-insulation-interlocks","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/vcb-commissioning-checklist-timing-insulation-interlocks\/","title":{"rendered":"\u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd (\u0bae\u0bc1\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0b95\u0bb3\u0baa\u0bcd\u0baa\u0ba3\u0bbf): \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd, \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd"},"content":{"rendered":"<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8. \u0b85\u0bb5\u0bc8, \u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f 60 \u0bae\u0bbf.\u0bb5\u0bbf.\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 90 \u0bae\u0bbf.\u0bb5\u0bbf. \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc8 \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd, \u0b92\u0baa\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bbe\u0bb0\u0bb0\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0bb5\u0b9a\u0bb0\u0bae\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f \u0b92\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bbe\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bc2\u0bb2 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b85\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb0\u0bc2\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b95\u0bc1\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0b95\u0bb3\u0baa\u0bcd\u0baa\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd, \u0b86\u0bb5\u0ba3\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b8e\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0ba9\u0bc1\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1: \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1\u0b9a\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0bcd, \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b86\u0b95\u0bbf\u0baf \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bbe\u0ba4 \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf, 12 kV, 24 kV, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 40.5 kV \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0ba8\u0b95\u0bb2\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1-\u0b92\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0baa\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\/\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0bae\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bbe\u0b95 \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0ba4\u0ba9\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1: \u0b8e\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0b8e\u0ba8\u0bcd\u0ba4 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc7\u0bb2\u0ba4\u0bbf\u0b95 \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"VCB \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd: 12kV-40.5kV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/xdqgsw5G0KU?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-field-commissioning-differs-from-factory-testing\">\u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0b86\u0bb2\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd (FAT), \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc2\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbe\u0ba9 \u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd, \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bcd, \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0baf\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbe\u0ba9 \u0ba4\u0bc2\u0b9a\u0bbf, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bcd \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0bb5\u0b95\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n\n\n\n<p><strong>1. \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1\/\u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b9a\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\/\u0ba4\u0bbf\u0bb0\u0bcd\u0ba3\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8 \u0b87\u0bb4\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0b95\u0ba3\u0bcd\u0ba3\u0bbe\u0bb2\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bbe\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0baa\u0bc6\u0bb2\u0bcd\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bb3\u0bcd \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0b95\u0b9a\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (NO \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd NC \u0b86\u0b95 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9)<\/li>\n\n\n\n<li>\u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0bb8\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9 (\u0baa\u0bc2\u0bae\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb8\u0bcd \u0bae\u0bc0\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8 (\u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n<\/ul>\n\n\n\n<p><strong>3. \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bae\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1000 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b89\u0baf\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, \u0b95\u0b9f\u0bb2\u0bcd \u0bae\u0b9f\u0bcd\u0b9f FAT-\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0b95\u0bc1\u0ba4\u0bbf \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0b85\u0ba4\u0bbf\u0b95 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd (\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bb3\u0bcd) \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0ba9\u0bbf \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0ba4\u0bb2\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bbf\u0bb5\u0bc1, \u0b85\u0ba9\u0bc1\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbe\u0b9a\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p>180 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, 22% VCB-\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b95\u0bb3\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0ba4\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u2014\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0bb5\u0bbf\u0bb2\u0b95\u0bb2\u0bcd (\u00b115%), \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<p>\u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/what-is-vacuum-circuit-breaker-working-principle\/\">\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0baa\u0ba3\u0bbf\u0baa\u0bc1\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd<\/a>&nbsp;\u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker-ratings\/\">\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd \u0baa\u0bb2\u0b95\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/a>&nbsp;\u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd, \u0b87\u0ba4\u0bc1 \u0b85\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bbf\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01.webp\" alt=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" class=\"wp-image-2403\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/field-vs-factory-vcb-testing-comparison-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 1. \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8, \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0ba4\u0bb3 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd, \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-1-pre-energization-safety-checks-30-minutes\">\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 1: \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd (30 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h2>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95&nbsp;<strong>\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9<\/strong>. \u0b87\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf, \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>1.1 \u0ba8\u0bc7\u0bb0\u0bbf\u0bb2\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00a0\u0bb7\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0baa\u0bbf\u0bb0\u0bbe\u0b95\u0bcd\u0b95\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0b95\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9 (\u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, VI \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd)<\/li>\n\n\n\n<li>\u00a0\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0ba8\u0bcd\u0ba8\u0bbf\u0baf\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/li>\n\n\n\n<li>\u00a0\u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bcd, \u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bb2\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u00a0\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0baa\u0bc1\u0bb7\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0baa\u0b9f\u0bbf \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9 (M12 \u0bb8\u0bcd\u0b9f\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 40-60 \u0ba8\u0bbf\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0ba9\u0bcd-\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd).<\/li>\n\n\n\n<li>\u00a0\u0baa\u0bc2\u0bae\u0bbf \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bb5\u0bc8 (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: &lt;0.1 \u03a9)<\/li>\n<\/ul>\n\n\n\n<p><strong>1.2 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00a0\u0b85\u0bb0\u0bc6\u0bb8\u0bcd\u0b9f\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u00a0\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bbe\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0b95\u0bb1\u0bcd\u0bb1 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u00a0\u0bb5\u0bbe\u0b9a\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0bb8\u0bcd \u0b89\u0baf\u0bbf\u0bb0\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u00a0\u0baa\u0bae\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bb3\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>\u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd (\u0b85\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf\u0b99\u0bcd \u0b86\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba8\u0bc6\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1, \u0bae\u0bc2\u0b9f\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd). \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0b85\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bcc\u0ba4\u0bc0\u0b95 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014IEC 62271-200-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf \u0bae\u0bc6\u0ba9\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0bb5\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2.<\/p>\n\n\n\n<p><strong>\u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0ba4\u0b9f\u0bc8\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<br><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1<\/strong>: \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0b95\u0bc7\u0bae\u0bcd\u0b95\u0bb3\u0bcd\/\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. 100% \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>1.3 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 (\u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd: 2.5 kV DC (12 kV VCB-\u0b95\u0bcd\u0b95\u0bc1), 5 kV DC (24 kV-\u0b95\u0bcd\u0b95\u0bc1)<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd-\u0baa\u0bc2\u0bae\u0bbf, \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd-\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd) \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>: &gt;1000 M\u03a9 (&gt;2000 M\u03a9 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1)<\/li>\n\n\n\n<li><strong>\u0b93\u0bb0\u0bb3\u0bb5\u0bc1<\/strong>\u00a0(100-1000 M\u03a9): \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bc1, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf<\/strong>\u00a0(&lt;100 M\u03a9): \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb2\u0bb0 \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p>\u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bb3 \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, 8% VCB-\u0b95\u0bb3\u0bcd \u0bb7\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b99\u0bcd\/\u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 2000 M\u03a9-\u0b90 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-2-contact-timing-tests-1-2-hours\">\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 2: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd (1-2 \u0bae\u0ba3\u0bbf\u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/h2>\n\n\n\n<p>\u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0b85\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0b9f\u0bc8\u0baa\u0bc6\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>2.1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>VCB \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (OMICRON CPC 100, Megger TM1800, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bae\u0bbe\u0ba9\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe \u0b8e\u0ba9 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bcb\u0b95\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0b9f\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd).<\/li>\n<\/ul>\n\n\n\n<p><strong>2.2 \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0bb5\u0b95\u0bc8 \u0bb5\u0bbe\u0bb0\u0bbf\u0baf\u0bbe\u0b95: \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd, \u0b9a\u0bcb\u0bb2\u0bbf\u0ba9\u0bbe\u0baf\u0bcd\u0b9f\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0bbe\u0bb2\u0bbf\u0b95\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0baf\u0ba3 \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0b9f\u0bc1<\/li>\n\n\n\n<li>\u0baa\u0baf\u0ba3 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (12 kV VCB, \u0bb5\u0b9a\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1)<\/strong>:<br>\u2022\u00a0<strong>\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd<\/strong>: 30-60 \u0bae\u0bbf.\u0bb5\u0bbf (IEC 62271-100 \u0bb5\u0bbf\u0ba4\u0bbf 6.111-\u0baa\u0b9f\u0bbf)<br>\u2022 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8: \u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bb2\u0b95\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u00b110%<br>\u2022 \u0bae\u0bc1\u0baa\u0bcd\u0baa\u0b95\u0bb2\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1: \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9\/\u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u22643 ms \u0bb5\u0bbf\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0b9a\u0bae\u0bcd<\/p>\n\n\n\n<p><strong>2.3 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>issue close \u0b95\u0b9f\u0bcd\u0b9f\u0bb3\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9<\/strong>: \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 60-100 \u0bae\u0bbf.\u0bb5\u0bbf<\/li>\n<\/ul>\n\n\n\n<p><strong>2.4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba8\u0bc6\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd \u0ba8\u0bc0\u0bb3\u0bae\u0bcd 2 \u0bae\u0bbf.\u0bb5\u0bbf-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0bb2 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd\u0b95\u0bb3\u0bcd (&gt;3) \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<p>\u0b95\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd \u0baa\u0bb2\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f 12% \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bae\u0bc0\u0bb1\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba9\u2014\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95. \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd 90% \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9; 10% \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02.webp\" alt=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bcb\u0baa\u0bcd \u0ba4\u0b9f\u0bae\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd.\" class=\"wp-image-2405\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-contact-timing-test-oscilloscope-trace-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 2. 12 kV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 IEC 62271-100 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd 30-60 ms \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd, 50 ms \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bcb\u0baa\u0bcd \u0ba4\u0b9f\u0bae\u0bcd. \u0b87\u0ba4\u0bbf\u0bb2\u0bcd 15 ms-\u0bb2\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 48 ms-\u0bb2\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-3-high-voltage-testing-2-3-hours\">\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 3: \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (2-3 \u0bae\u0ba3\u0bbf\u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/h2>\n\n\n\n<p>\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>3.1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd (PFWT)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd: 12 kV \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 28 kV RMS (IEC 62271-100 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8 1-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf)<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0bb2\u0bae\u0bcd: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 1 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd), \u0b95\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>: \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8, \u0b9f\u0bbf\u0bb0\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0b99\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8, \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd &gt;10 pC<\/li>\n<\/ul>\n\n\n\n<p><strong>3.2 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>&nbsp;(\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd)<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>12 kV \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 75 kV \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd<\/li>\n\n\n\n<li>15 \u0ba8\u0bc7\u0bb0\u0bcd\u0bae\u0bb1\u0bc8 + 15 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bae\u0bb1\u0bc8 \u0b89\u0ba8\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>: \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>3.3 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (100 A DC \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1)<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>\u00a0(12 kV, 630 A \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd): \u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 &lt;150 \u00b5\u03a9<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>\u00a0(24 kV, 1250 A \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd): \u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 &lt;80 \u00b5\u03a9<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1: &lt;20%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8<\/strong>:<br>IEC 62271-100, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95, \u2265100 A \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b8e.\u0b95\u0bbe., \u0bae\u0bb2\u0bcd\u0b9f\u0bbf\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd mA \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1) 100 A \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0ba4\u0bc1\u0bb3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0baa\u0b9f\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b89\u0baf\u0bb0\u0bcd-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/iec-62271-100-type-test-vs-routine-test-vcb-rfq\/\">IEC 62271-100 \u0bb5\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/a>&nbsp;\u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba4\u0bc1&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vcb-maintenance-checklist\/\">\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/a>. \u0b85\u0ba4\u0bbf\u0b95\u0bbe\u0bb0\u0baa\u0bcd\u0baa\u0bc2\u0bb0\u0bcd\u0bb5 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b87\u0b99\u0bcd\u0b95\u0bc7 \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6734\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 62271-100<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-4-control-circuit-functional-tests-1-hour\">\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 4: \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd (1 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/h2>\n\n\n\n<p><strong>4.1 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 NO\/NC \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95<\/li>\n\n\n\n<li>\u0ba4\u0bbf\u0bb1\/\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 5-10 A) \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd\u0bb3\u0bbe\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>: \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/li>\n<\/ul>\n\n\n\n<p><strong>4.2 \u0baa\u0bae\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0baf\u0ba3\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bb3\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bc8 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bc7 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bcd \u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1)<\/li>\n\n\n\n<li><strong>\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf<\/strong>: \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0baa\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bbf-\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd)\u2014\u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>4.3 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 70% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b8e.\u0b95\u0bbe., 110 VDC \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 77 VDC).<\/li>\n\n\n\n<li>\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc2\u0b9f \u0bae\u0bb1\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>: 70-80% \u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc1\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>4.4 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b89\u0ba4\u0bb5\u0bbf\u0b95\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0bb4\u0bc1 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u2192 \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u2192 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4<\/li>\n\n\n\n<li>\u0baa\u0bbf\u0bb4\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p>95 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, 15% \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd NO\/NC \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0ba9\u0bb0\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8, \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b87\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"572\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03.webp\" alt=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8, \u0baa\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b93\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" class=\"wp-image-2406\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03.webp 572w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03-168x300.webp 168w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-control-circuit-functional-test-flowchart-03-7x12.webp 7w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 3. \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd, \u0baa\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bc1\u0bb1\u0bc8-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\/\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b93\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bae\u0bcd.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-5-documentation-validation-30-minutes\">\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 5: \u0b86\u0bb5\u0ba3 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 (30 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h2>\n\n\n\n<p>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0b95\u0bbe\u0ba4\u0bc0\u0bb0\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1 \u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4\u0b9a\u0bcd \u0b9a\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0ba4\u0bcd \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00a0IEC 62271-100 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd (\u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1: KEMA, CESI, CPRI)<\/li>\n\n\n\n<li>\u00a0\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8 (\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd)<\/li>\n\n\n\n<li>\u00a0\u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd (CAD \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u00a0\u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bc7\u0b9f\u0bc1 (O&amp;M \u0b95\u0bc1\u0bb4\u0bc1\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0bae\u0bca\u0bb4\u0bbf)<\/li>\n\n\n\n<li>\u00a0\u0baa\u0bbe\u0b95 \u0b8e\u0ba3\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u00a0\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong>: \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u201c12 kV, 630 A, 25 kA\u201d\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd, \u201c12 kV, 630 A, 31.5 kA\u201d \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0bbe\u0ba4\u0bc1\u2014\u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf \u0bb5\u0b95\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8.<\/p>\n\n\n\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd \u0baa\u0bb2\u0b95\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0ba4\u0bcd \u0ba4\u0bc7\u0ba4\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (2 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0bb5\u0baf\u0b95\u0bcd\u0baf\u0bc2\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baf\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0b95\u0b9f\u0bc1 \u0ba4\u0bb0\u0bb5\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0b86\u0bb0\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p>\u0b86\u0bb5\u0ba3\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0bb2\u0bcd, \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd, \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd 12% VCB \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bcb\u0bae\u0bcd. \u0b9a\u0baa\u0bcd\u0bb3\u0bc8\u0baf\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 3-8 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0ba9\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"phase-6-load-testing-and-monitoring-first-30-days\">\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 6: \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (\u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30 \u0ba8\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bcd)<\/h2>\n\n\n\n<p><strong>6.1 \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc1\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd\u0bb1\u0bbf \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bbf \u0b8e\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b95\u0bc0\u0bb4\u0bcd\u0ba4\u0bcd\u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8)<\/li>\n\n\n\n<li>2 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u0b85\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b9a\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1<\/li>\n\n\n\n<li>24 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (1000 M\u03a9-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p><strong>6.2 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8 \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95 25%, 50%, 75%, 100% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (IR \u0b95\u0bc7\u0bae\u0bb0\u0bbe \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1)<\/li>\n\n\n\n<li><strong>\u0b95\u0b9f\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd<\/strong>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0394T &lt;50 K<\/li>\n<\/ul>\n\n\n\n<p><strong>6.3 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 10 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc1\u0ba4\u0bb2\u0bcd 10 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\/\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>3-5 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1, \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u00b15 ms-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bc6\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<p><strong>IEC 62271-100-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>:<br>\u2022 \u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd: \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd &lt;75 K<br>\u2022 \u0bb5\u0bc6\u0bb3\u0bcd\u0bb3\u0bbf \u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd: &lt;80 K<br>\u2022 \u0baa\u0bcb\u0bb2\u0bcd\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb8\u0bcd \u0baa\u0bbe\u0bb0\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd: &lt;105 K<br>\u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1, \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bb1\u0bcd\u0bb1 \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>200-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd 95% \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30 \u0ba8\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9\u2014\u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0bb5\u0ba4\u0bc1, \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4\u0b95\u0bcd \u0b95\u0bbe\u0bb2\u0bbe\u0bb5\u0ba4\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0bbf\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04.webp\" alt=\"\u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bc8\u0bb2\u0bcd\u0b95\u0bb1\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30-\u0ba8\u0bbe\u0bb3\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb2\u0b95\u0bcd\u0b95\u0bcb\u0b9f\u0bc1\" class=\"wp-image-2402\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-first-30-day-monitoring-schedule-timeline-04-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 4. \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 95%-\u0b90 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30-\u0ba8\u0bbe\u0bb3\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd (\u0ba8\u0bbe\u0bb3\u0bcd 1), \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (\u0ba8\u0bbe\u0bb3\u0bcd 7), \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 (\u0ba8\u0bbe\u0bb3\u0bcd 14), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bc1\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (\u0ba8\u0bbe\u0bb3\u0bcd 30).<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-commissioning-failures-and-root-causes\">\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0bb2 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf: \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bbf\u0b9f &gt;15% \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbe\u0bb2\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd: \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b95\u0bc7\u0b9c\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8)<\/li>\n\n\n\n<li>\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1: \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\/\u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf: \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 &lt;100 M\u03a9<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1\/\u0b95\u0baa\u0bcd\u0baa\u0bb2\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1: 8-12 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0bae\u0bcd 40\u00b0C \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1: \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b90\u0baa\u0bbf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe \u0b8e\u0ba9\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0baa\u0bb4\u0bc1\u0ba4\u0bc1: \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc1\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc7 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bbe\u0ba9 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n\n\n\n<li>\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1: \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1-\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd (\u0bb2\u0bbe\u0b95\u0bcd\u0b9f\u0bc8\u0b9f\u0bcd, \u0bb2\u0bbe\u0b95\u0bcd \u0bb5\u0bbe\u0bb7\u0bb0\u0bcd\u0b95\u0bb3\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 &gt;200 \u00b5\u03a9<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd: \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b86\u0b95\u0bcd\u0b9a\u0bbf\u0b9c\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd (\u0b90\u0b9a\u0bcb\u0baa\u0bbf\u0bb0\u0bc8\u0bb2\u0bcd \u0b86\u0bb2\u0bcd\u0b95\u0bb9\u0bbe\u0bb2\u0bcd), \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1: \u0ba8\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bae\u0bbe\u0ba4\u0ba8\u0bcd\u0ba4\u0bcb\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8<\/h2>\n\n\n\n<p>\u0b86\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0ba4\u0bb0\u0bae\u0bcd, \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb3-\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1. \u0b95\u0bb3-\u0bae\u0bc1\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd, \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0 \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1.<\/p>\n\n\n\n<p>\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1: \u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd. \u0baa\u0b9f\u0bbf\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0ba4\u0bb5\u0bb1\u0bbe\u0b95 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bbe\u0ba4\u0bb5\u0bbf\u0ba4\u0bae\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0bb5\u0bc6\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb2\u0bcd\u0bb2. \u0b87\u0ba4\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b95\u0bb3\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb2\u0bcd\u0bb2\u0bc1\u0ba8\u0bb0\u0bcd\u0b95\u0bb3\u0bbe\u0bb2\u0bcd, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0bb5\u0ba4\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0ba4\u0bc2\u0b9a\u0bbf, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd, \u0ba8\u0bc7\u0bb0 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0ba8\u0ba9\u0bcd\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 95% \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b85\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0bae\u0ba3\u0bbf\u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd, \u0bae\u0bc1\u0bb4\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vcb-commissioning\">\u0baa\u0bbf\u0bb1\u0bcd\u0baa\u0ba3\u0bbf\u0baf\u0bbf\u0b9f\u0bb2\u0bcd: VCB<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: 12 kV \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd, \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong><\/p>\n\n\n\n<p>IEC 62271-100, \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 (field commissioning) \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 2.5 kV DC \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd &gt;1000 M\u03a9 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (&gt;2000 M\u03a9 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1). 100-1000 M\u03a9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bcb\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd, \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0bc1\u0ba3\u0bcd-\u0b9a\u0bbf\u0bb1\u0bc1\u0ba4\u0bc1\u0bb3\u0bc8\u0b95\u0bb3\u0bc8 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. 100 M\u03a9-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd. 40\u00b0C \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 8-12 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b95\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bb3 \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 8% \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 2000 M\u03a9 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0bc1\u0bb1\u0bcd\u0bb1 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0ba4\u0b9f\u0bc8\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: (1) \u0bae\u0ba3\u0bcd\u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bbf\u0baf\u0bc8 \u0b86\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b85\u0ba4\u0bc1 \u0baa\u0bcc\u0ba4\u0bc0\u0b95 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd; (2) \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b85\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd; (3) \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba3\u0bc1\u0b95 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b95\u0ba4\u0bb5\u0bc1 \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. IEC 62271-200-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf \u0bae\u0bc6\u0ba9\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0bb5\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0bb2\u0bc7\u0b9a\u0bbe\u0ba9 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bb2\u0bcd\u0bb2; \u0b92\u0bb0\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb2\u0bcd\u0bb2\u0bc1\u0ba8\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baf\u0ba4\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0ba4\u0b9f\u0bc8\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 100% \u0b89\u0b9f\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1 \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc73: \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9\u0bc6\u0ba9\u0bcd\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8?<\/strong><\/p>\n\n\n\n<p>IEC 62271-100 \u0bb5\u0bbf\u0ba4\u0bbf 6.111, 12 kV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 30-60 ms \u0b8e\u0ba9\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd). \u0b95\u0bb3 \u0b8f\u0bb1\u0bcd\u0baa\u0bc1 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bb2\u0b95\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u00b110% \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95: 50 ms \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 45-55 ms \u0bb5\u0bb0\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1-\u0b95\u0b9f\u0bcd\u0b9f \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 (\u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9\/\u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0baa\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1) \u22643 ms \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bb2\u0b95\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0b83\u0baa\u0bcd\u0b9f\u0bcd &gt;15% \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0bc1, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1. \u0b95\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 12% \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bae\u0bc0\u0bb1\u0bbf\u0baf\u0ba4\u0bbe\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1; \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd 90% \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8\u0baf\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, 10% \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0baa\u0bb5\u0bc8\u0baf\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba9. 5 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc74: VCB-\u0b95\u0bcd\u0b95\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bbe?<\/strong><\/p>\n\n\n\n<p>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8. \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; \u0b95\u0bb3 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1, \u0b9a\u0bc7\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd (\u0b95\u0ba3\u0bcd\u0ba3\u0bbe\u0bb2\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bbe\u0ba4\u0bc1). \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd\u2014\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd\u2014\u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. IEC 62271-100 \u0b86\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; IEC 62271-200 (\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1) \u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bc7\u0baf\u0bc7 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8: \u0b86\u0bb2\u0bc8 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 80% \u0b85\u0bb3\u0bb5\u0bc8 1 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd (\u0b8e.\u0b95\u0bbe., 12 kV \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 28 kV \u00d7 0.8 = 22.4 kV). \u0b86\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 5%-\u0b87\u0bb2\u0bcd, \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc75: \u0b92\u0bb0\u0bc1 VCB \u0b86\u0ba9\u0bcd-\u0b9a\u0bc8\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bae\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd, \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc6\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><\/p>\n\n\n\n<p>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8: (1) \u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0baf\u0bcd\u0bb5\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 (KEMA, CESI, CPRI) \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd; (2) \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8; (3) \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3 CAD \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd; (4) \u0ba4\u0bb3 \u0bae\u0bca\u0bb4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bc7\u0b9f\u0bc1; (5) \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1: \u0bb5\u0b95\u0bc8-\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014\u201c12 kV, 25 kA\u201d\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd \u201c12 kV, 31.5 kA\u201d-\u0b90\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbe\u0ba4\u0bc1 (\u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0ba4\u0ba9\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8). \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd \u0baa\u0bb2\u0b95\u0bc8 \u2192 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u2192 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bae\u0bcd \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd. \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9\/\u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd 12% \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9; \u0b9a\u0baa\u0bcd\u0bb3\u0bc8\u0baf\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 3-8 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0ba9\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc76: \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0ba8\u0bbe\u0ba9\u0bcd \u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bcb\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bbf-\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf-\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8: (1) \u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bbf, \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0b87\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0bb5\u0bc1\u0bae\u0bcd; (2) \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bcd\/\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd; (3) \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bb3\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bc8 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc2\u0bb2\u0bae\u0bcd); (4) \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc7 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd; (5) \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bc8 \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b92\u0bb0\u0bc7 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8: \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u201c\u0baa\u0bae\u0bcd\u0baa\u0bbf\u0b99\u0bcd\u201d \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bc1-\u0ba4\u0bbf\u0bb1-\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd) \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd. \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf: \u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 52a\/52b \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1) \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bb5\u0b95\u0bc8 \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0bb5\u0bc1\u0bae\u0bcd. \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bb3 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b9a\u0bbf\u0bb2 \u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4-\u0b89\u0ba3\u0bb0\u0bcd\u0bb5\u0bc1\u0b9f\u0bc8\u0baf\u0bb5\u0bc8. \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bbf\u0baf\u0bb5\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bbe\u0bb2\u0bcd 8% \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b86\u0ba9\u0bcd\u0b9f\u0bbf-\u0baa\u0bae\u0bcd\u0baa\u0bcd \u0bae\u0bc1\u0b9f\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\/\u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc77: \u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong><\/p>\n\n\n\n<p>IEC 62271-100 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd &lt;75 K, \u0bb5\u0bc6\u0bb3\u0bcd\u0bb3\u0bbf \u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd &lt;80 K, \u0baa\u0bcb\u0bb2\u0bcd\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb8\u0bcd \u0baa\u0bbe\u0bb0\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd &lt;105 K. \u0b95\u0bb3 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8: 2 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0 \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 100% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0bb5\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc7\u0bae\u0bb0\u0bbe\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd. \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f 50 K-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1 (\u0ba4\u0bb0\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bb3\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 M12 \u0bb8\u0bcd\u0b9f\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 40-60 N\u22c5m), \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (\u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b90\u0b9a\u0bcb\u0baa\u0bbf\u0bb0\u0bca\u0baa\u0bbf\u0bb2\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0baa\u0bb8\u0bcd \u0baa\u0bbe\u0bb0\u0bcd-\u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd). \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd 200 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, 10% \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b9f\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbe\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0ba4\u0bc1; 3% \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0baa\u0bb8\u0bcd\u0baa\u0bbe\u0bb0\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0bb2\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1. \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb5\u0bbf\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 30 \u0ba8\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b87\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum circuit breaker commissioning failures don\u2019t announce themselves during factory acceptance tests. They surface at site energization when auxiliary contacts chatter due to vibration, when timing tests reveal 90 ms opening instead of the specified 60 ms, or when documentation gaps delay project handover by weeks while the contractor scrambles to produce missing certificates. These [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2404,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24,27],"tags":[],"class_list":["post-2401","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2401"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2401\/revisions"}],"predecessor-version":[{"id":3577,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2401\/revisions\/3577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2404"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2401"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}