{"id":2409,"date":"2026-01-03T08:28:34","date_gmt":"2026-01-03T08:28:34","guid":{"rendered":"https:\/\/xbrele.com\/?p=2409"},"modified":"2026-04-07T13:32:04","modified_gmt":"2026-04-07T13:32:04","slug":"transformer-inrush-current-nuisance-trips-prevention","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/transformer-inrush-current-nuisance-trips-prevention\/","title":{"rendered":"\u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd: \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd"},"content":{"rendered":"<p>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd, \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0bae\u0bc8\u0baf\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bbf\u0ba9\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb0\u0bc1\u0b95\u0bc7 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0ba8\u0b9f\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0b9a\u0bae\u0b9a\u0bcd\u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bbf, \u0bae\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bb3\u0bcd\u0bb3\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc1\u0bae\u0bc8 0.5-2%-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1, 8-15\u00d7 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0bb4\u0bc1-\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bbe\u0b95 \u0bb5\u0bbe\u0ba9\u0bb3\u0bbe\u0bb5 \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1, 0.1-0.5 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd \u0918\u093e\u0924\u0940\u092f \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1, \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0b95 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b8e\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4reshold-\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0ba9 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbe\u0ba9 \u0bae\u0bbe\u0baf \u201c\u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u201d \u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0baa\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b87\u0b9f\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd (ATS) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bb2 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0b9f\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 2000 kVA \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0bb5\u0b9a\u0ba4\u0bbf, \u0bae\u0bbf\u0ba9\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc1\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 15-20 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bbe\u0ba4 \u201c\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u201d \u0b86\u0bb0\u0bbe\u0baf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd, \u0b9a\u0bbf\u0bb2 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd, \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 90%+ \u0bae\u0bc1\u0b9f\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0ba9\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd: \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/5aj8nbikJns?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-transformer-inrush-exceeds-normal-magnetizing-current\">\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0b8f\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u2014\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd 0.5-2%. \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b83\u0baa\u0bbe\u0bb0\u0b9f\u0bc7\u0bb5\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba4\u0bbf \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bbf\u0bb2 \u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd), \u0b87\u0ba4\u0bc1 \u0bae\u0bc8\u0baf \u0b8e\u0b83\u0b95\u0bc1 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0b89\u0b9a\u0bcd\u0b9a \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 30-80TP3T \u0bb5\u0bb0\u0bc8 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0bae\u0bb1\u0bc1\u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0437\u0430\u043b\u0438\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/strong>\u00a0\u0b89\u0baf\u0bb0\u0bcd (\u03a6_max-\u0b87\u0ba9\u0bcd 80%)<\/li>\n\n\n\n<li><strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b89\u0b9f\u0ba9\u0b9f\u0bbf<\/strong>\u00a0\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li><strong>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba8\u0bbf\u0bb2\u0bc8<\/strong>\u00a0\u0437\u0430\u043b\u0438\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9 (\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1)<\/li>\n<\/ol>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd, \u0bae\u0bca\u0ba4\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bc1\u0bb4\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd:<br>\u03a6<sub>\u0bae\u0bca\u0ba4\u0bcd\u0ba4\u0bae\u0bcd<\/sub>\u00a0= \u0b83\u0baa\u0bbf<sub>\u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/sub>\u00a0+ \u0b83\u0baa\u0bbf<sub>\u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3<\/sub>\u00a0\u2248 1.0 + 0.8 =\u00a0<strong>1.8 \u0baa\u0b99\u0bcd\u0b95\u0bc1.<\/strong><br><br>\u0b95\u0bb0\u0bc1 \u0bae\u0bc8\u0baf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1 ~1.2-1.3 p.u. \u0b87\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b8e\u0ba9\u0bb5\u0bc7 \u0b87\u0ba8\u0bcd\u0ba4 1.8 p.u. \u0ba4\u0bc7\u0bb5\u0bc8 \u0bae\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb4\u0bae\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba4\u0bb3\u0bcd\u0bb3\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bbf\u0bb2\u0bcd, \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8 \u0b85\u0b9f\u0bc8\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.[HTML-<\/p>\n\n\n\n<p><strong>\u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bc7\u0bb0\u0bb3\u0bb5\u0bc1<\/strong>\u0baa\u0b95\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 (200 kVA \u2013 2500 kVA) \u0bae\u0bc1\u0bb4\u0bc1-\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 8-12 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1. \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (&gt;10 MVA) \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b95\u0bcb\u0bb0\u0bcd \u0ba4\u0bb0\u0bae\u0bcd (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b85\u0ba4\u0bbf\u0b95 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1) \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 15-20 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8 \u0b85\u0b9f\u0bc8\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bbe\u0baf\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bbe\u0bb1\u0bbf<\/strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb0\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bbe\u0bb2\u0bcd \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0bae\u0b99\u0bcd\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd (50-200 ms), \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1-\u0b92\u0bb0\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd\u0bb7\u0bc8 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd (200-500 ms).<\/p>\n\n\n\n<p>\u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/transformer-impedance-percentage-guide\/\">\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 Z%<\/a>&nbsp;\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0ba9\u0bcd \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd-\u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b87\u0ba4\u0bc1 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1, \u0b85\u0ba4\u0bc7\u0b9a\u0bae\u0baf\u0bae\u0bcd \u0b83\u0baa\u0bbe\u0bb2\u0bcd\u0b9f\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\/\u0bb5\u0bbf\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01.webp\" alt=\"\u0b8e\u0ba9\u0bb0\u0bcd\u0b9a\u0bc8\u0b9a\u0bc7\u0bb7\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb0\u0bcd \u0b9a\u0bbe\u0b9a\u0bcd\u0b9a\u0bc1\u0bb0\u0bc7\u0bb7\u0ba9\u0bc1\u0bae\u0bcd 1.8 \u0baa\u0bc6\u0bb0\u0bcd-\u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2410\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-flux-time-energization-saturation-curve-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 1. \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9-\u0bb5\u0b95\u0bc8 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8: \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 (0.8 p.u.) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf-\u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8 1.8 p.u. \u0b86\u0b95 \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf, \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4reshold-\u0b90 (1.2 p.u.) \u0bae\u0bc0\u0bb1\u0bbf, \u0b92\u0bb0\u0bc1 \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"harmonic-content-the-key-to-discrimination\">\u0b87\u0b9a\u0bc8\u0b95\u0bcd\u0b95\u0bcb\u0bb0\u0bcd\u0bb5\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd: \u0baa\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bb1\u0bbf\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb1\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd<\/h2>\n\n\n\n<p>\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 30-70% \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0b92\u0bb2\u0bbf\u0bae\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8 (50 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 100 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd, 60 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 120 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd) \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bc1\u0baf\u0bb2\u0bbf\u0ba9\u0bcd \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0b9a\u0bae\u0b9a\u0bcd\u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0b85\u0bb0\u0bc8-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bca\u0ba9\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b92\u0bb2\u0bbf\u0bae\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0bae\u0bcd, \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bae\u0bbe\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 (50\/60 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd)<\/strong>: 100% (\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1)<\/li>\n\n\n\n<li><strong>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1<\/strong>: 30-70% (\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0bae\u0bcd\u0b9a\u0bae\u0bcd)<\/li>\n\n\n\n<li><strong>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bbe\u0bae\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bca\u0bb2\u0bbf<\/strong>: 10-20%<\/li>\n\n\n\n<li><strong>\u0b89\u0baf\u0bb0\u0bcd \u0b92\u0bb2\u0bbf\u0bae\u0bbf\u0b95\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: &lt;5%<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8<\/strong>: 100%<\/li>\n\n\n\n<li><strong>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1<\/strong>: &lt;5% (\u0b9a\u0bbf\u0bb1\u0bbf\u0baf)<\/li>\n<\/ul>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1&nbsp;<strong>\u0b87\u0b9a\u0bc8\u0ba8\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb3\u0bcd<\/strong>&nbsp;\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b9a\u0bae\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95. \u0bb0\u0bbf\u0bb2\u0bc7, \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd-\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 15-20%) \u0bb5\u0bbf\u0b9e\u0bcd\u0b9a\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd, \u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b8e\u0ba9\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bbf, \u0ba8\u0bbf\u0bb0\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 (0.5-2 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd) \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b87\u0b9a\u0bc8 \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1)<\/strong>:<br>\u0b87\u0b83\u0baa\u0bcd (\u0ba8\u0bbe\u0ba9\u0bcd<sub>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bb5\u0ba4\u0bc1 \u0b92\u0ba4\u0bcd\u0ba4\u0bca\u0bb2\u0bbf<\/sub>\u00a0\/ \u0ba8\u0bbe\u0ba9\u0bcd<sub>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8<\/sub>) &gt; 0.18 \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd<br>\u00a0\u00a0\u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1 (50\/51)<br>\u00a0\u00a00.5-1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0ba4\u0bbe\u0bae\u0ba4-\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<br>\u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1<br>\u00a0\u00a0\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<br>\u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd<\/p>\n\n\n\n<p>95 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0bb2-\u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bbf\u0bb4\u0bc8-\u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 85-95% \u0bb5\u0bb0\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/transformer-protection-vcb-inrush-coordination-mistakes\/\">VCB \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"factors-that-worsen-inrush-transformer-design-and-system-conditions\">\u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bcd: \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc7 \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbe\u0ba4\u0bc1. \u0b85\u0ba4\u0ba9\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb1\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n\n\n\n<p><strong>1. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bbe\u0ba9\u0bbf\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0b9a\u0bbf\u0bb2\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bcd \u0b8e\u0b83\u0b95\u0bc1 (CRGO)<\/strong>: \u0b85\u0ba4\u0bbf\u0b95 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u2192 60-80% \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0ba8\u0bc6\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd<\/li>\n\n\n\n<li><strong>\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bb1\u0bcd\u0bb1 \u0b89\u0bb2\u0bcb\u0b95 \u0bae\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 (30-50%) \u2192 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>2. \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (&gt;2500 kVA) \u0b92\u0bb0\u0bc1 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9 \u2192 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0bae\u0b99\u0bcd\u0b95\u0bb2\u0bcd \u0b95\u0bbe\u0bb2 \u0bae\u0bbe\u0bb1\u0bbf\u0b95\u0bb3\u0bcd \u2192 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>3. \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1 (\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bb1\u0bcd\u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1): \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 30-80% \u0bb5\u0bb0\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1 (\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1): \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 ~80% (\u0bae\u0bbf\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8)<\/li>\n<\/ul>\n\n\n\n<p><strong>4. \u0b86\u0ba4\u0bbe\u0bb0\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0ba4\u0bbe\u0bb0\u0bae\u0bcd<\/strong>\u00a0(\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd, \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd): \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0bb2\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0b85\u0ba4\u0bbf\u0b95 \u0b89\u0b9a\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li><strong>\u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0b86\u0ba4\u0bbe\u0bb0\u0bae\u0bcd<\/strong>\u00a0(\u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd, \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd): \u0bae\u0bc2\u0bb2 \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc6\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>5. \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd \u0b95\u0bcb\u0ba3\u0bae\u0bcd<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/strong>: \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b9a\u0bae\u0b9a\u0bcd\u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u2192 \u0bae\u0bbf\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0ba8\u0bc6\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd<\/li>\n\n\n\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd<\/strong>: \u0b9a\u0bae\u0b9a\u0bcd\u0b9a\u0bc0\u0bb0\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u2192 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b89\u0bb3\u0bcd\u0ba8\u0bc6\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd (1-2\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p><strong>6. \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb0\u0bb2\u0bbe\u0bb1\u0bc1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1: \u0b85\u0ba4\u0bbf\u0b95 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1.<\/li>\n\n\n\n<li>\u0b9a\u0bc1\u0bae\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0baa\u0bcb\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0bc1\u0b9f\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bcd \u0b95\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02.webp\" alt=\"\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b86\u0bb1\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bc8 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd, \u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bcb\u0bb0\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b95\u0bcb\u0ba3\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba9.\" class=\"wp-image-2413\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-severity-factors-contribution-chart-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 2. \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b86\u0bb1\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bcd: \u0b95\u0bcb\u0bb0\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd (\u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1), \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b95\u0bcb\u0ba3\u0bae\u0bcd (\u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc8 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"protection-coordination-strategies-to-prevent-nuisance-trips\">\u0ba4\u0bca\u0ba8\u0bcd\u0ba4\u0bb0\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b90\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; \u0b85\u0bb5\u0bc8 \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 (\u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f) \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba8\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc8 \u0bb5\u0bb0\u0bc8 \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-1-time-delayed-overcurrent\">\u0bb5\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf 1: \u0b95\u0bbe\u0bb2 \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/h3>\n\n\n\n<p>\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0b99\u0bcd\u0b95\u0bb2\u0bcd \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. 1000-2500 kVA \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 0.5-1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b8e\u0bb3\u0bbf\u0ba4\u0bc1 (\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b9f\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f-\u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0ba4\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9)<\/li>\n\n\n\n<li>\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8<\/li>\n\n\n\n<li>\u0b8e\u0ba8\u0bcd\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0bb2\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd 0.5-1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bbe\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd: 1.3-1.5\u00d7 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd: 0.8-1.2 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd (\u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-2-harmonic-restraint-preferred-for-automatic-systems\">\u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8 2: \u0b87\u0b9a\u0bc8\u0bb5\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 (\u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1)<\/h3>\n\n\n\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd (SEL-387, ABB REF615, Schneider Sepam) \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd-\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9. I_2nd \/ I_fundamental &gt; 18% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba8\u0bbf\u0bb0\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (SEL-387)<\/strong>:<br><code>87P = 0.25 \u0baa\u0bc1<\/code>\u00a0(\u0bb5\u0bbf\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0b9a\u0baa\u0bcd \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd, 25% \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1)<br><code>87S = 35%<\/code>\u00a0(\u0baa\u0bbf\u0bb3\u0bb5\u0bc1 \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1)<br><code>\u0baa\u0bbf\u0b9a\u0bbf\u0b9f\u0bbf2 = 181\u0b9f\u0bbf\u0baa\u0bbf3\u0b9f\u0bbf<\/code>\u00a0(\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd-\u0b87\u0b9a\u0bc8\u0bae\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4reshold)<br><code>INHST = 5.0 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/code>\u00a0(\u0ba4\u0b9f\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd\u0bb8\u0bcd 100 \u0bae\u0bbf.\u0bb5\u0bbf.\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<\/p>\n\n\n\n<p><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8)<\/li>\n\n\n\n<li>\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1 (ATS, \u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8 (\u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0b9a\u0bbf\u0bb2 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0baa\u0bb4\u0bc8\u0baf \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b95\u0bb3\u0bcd) &lt;15% \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/strong>\u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bc8\u0b95\u0bcd\u0b95\u0bc1 4-6 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0b9a\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4-\u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 92% \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-3-controlled-switching-point-on-wave\">\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bbe\u0bb5\u0ba4\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf: \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd (\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd-\u0b85\u0bb2\u0bc8)<\/h3>\n\n\n\n<p>\u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bae\u0b9a\u0bcd\u0b9a\u0bc0\u0bb0\u0bbe\u0b95 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf, \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 1-2 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (ABB Switchsync, Siemens POSA)<\/li>\n\n\n\n<li>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b85\u0bb3\u0ba8\u0bcd\u0ba4\u0bc1, \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0b95\u0bcb\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bb3\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd.<\/li>\n\n\n\n<li>\u0b9a\u0bc0\u0bb0\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd (\u00b12 ms \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd) \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bca\u0bb2\u0bbf \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bae\u0bb2\u0bcd, 85-95% \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8 (\u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1 4,000-15,000 \u0bb0\u0bc2\u0baa\u0bbe)<\/li>\n\n\n\n<li>\u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf VCB \u0ba4\u0bc7\u0bb5\u0bc8 (\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bb5\u0b9a\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0bb4\u0bc8\u0baf \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1<\/strong>: \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (&gt;5 MVA), \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-4-pre-insertion-resistors\">\u0b89\u0ba4\u0bcd\u0ba4\u0bbf 4: \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd \u0b95\u0bcb\u0bb0\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0baa\u0bbf\u0bb1\u0b95\u0bc1 (50-100 ms) \u0b85\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1<\/strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u2192 50-100 \u0bae\u0bbf.\u0bb5\u0bbf. \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd \u2192 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf<\/p>\n\n\n\n<p><strong>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1<\/strong>:<br>R = V<sub>\u0b9a\u0bbf\u0b95\u0bb0\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0bcd\u0b95<\/sub>\u00a0\/ \u0ba8\u0bbe\u0ba9\u0bcd<sub>\u0b95\u0bc1\u0bb4\u0bc1\u0bae\u0bae\u0bcd,\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd<\/sub><br>12 kV \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bcd 2 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd (\u0b8e.\u0b95\u0bbe., 1000 kVA \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 100 A):<br>R = 16,970 V \/ 100 A =\u00a0<strong>170 \u0b93\u0bae\u0bcd<\/strong><br>\u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1: \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b95\u0bbe\u0bb2 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd = I\u00b2 \u00d7 R \u00d7 t = (100)\u00b2 \u00d7 170 \u00d7 0.050 =\u00a0<strong>85 \u0b95\u0bbf\u0bb2\u0bcb\u0b9c\u0bcc\u0bb2\u0bcd<\/strong><\/p>\n\n\n\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd (\u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bbe\u0bb2\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1)<\/li>\n\n\n\n<li>\u0d31\u0d46\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b85\u0ba4\u0bc1 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1).<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"strategy-5-sequential-energization-with-delay\">\u0b89\u0ba4\u0bcd\u0ba4\u0bbf 5: \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd<\/h3>\n\n\n\n<p>\u0baa\u0bb2 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, 30-60 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd; \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb8\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9<\/strong>: \u0b87\u0ba3\u0bc8\u0ba4\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd\u2014\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95, \u0b87\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bbf\u0ba9\u0bcd 1.5 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8 \u0b8e\u0b9f\u0bcd\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03.webp\" alt=\"\u0b90\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1, \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba3\u0bbf\u0bb5\u0bbf\u0baf\u0bb2\u0bcd.\" class=\"wp-image-2412\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/transformer-inrush-protection-strategy-comparison-matrix-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 3. \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1: \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1-\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (85-95% \u0baa\u0baf\u0ba3\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1); \u0baa\u0bbe\u0baf\u0bbf\u0ba3\u0bcd\u0b9f\u0bcd-\u0b86\u0ba9\u0bcd-\u0bb5\u0bc7\u0bb5\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0bb2\u0bcd; \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bae\u0bb0\u0b9a\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sympathetic-inrush-when-energizing-one-transformer-trips-others\">\u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1: \u0b92\u0bb0\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc8 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0baa\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0baa\u0bb8\u0bcd\u0bb8\u0bbf\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8 \u0b87\u0ba3\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd, \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bb8\u0bcd\u0bb8\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf, \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0b9f\u0bbf \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u201c\u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd\u201d (sympathetic inrush) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b92\u0ba4\u0bcd\u0ba4\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bcb\u0b9f\u0bcd\u0b9f \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong>:<br>1. \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd A \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0baa\u0bc7\u0bb8\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 10\u00d7 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b88\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<br>2. \u0bae\u0bc2\u0bb2\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0baa\u0bc7\u0bb8\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 5-15%<br>3. \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd B \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd C (\u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bb5\u0bc8) \u0b88\u0b9f\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<br>4. \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd = \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf A-\u0bb5\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd + \u0b9a\u0bae\u0bcd\u0baf\u0bc1\u0baa\u0bbe\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (B+C)<br>\u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1: \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b87\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0bb2\u0bcd \u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1-\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0ba9\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2)<\/li>\n\n\n\n<li>\u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 1.5-2.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>30-60 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbe\u0bae\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p>40 \u0baa\u0bb2\u0bcd-\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0b95\u0bcd\u0b95\u0bbf \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b85\u0ba9\u0bc1\u0ba4\u0bbe\u0baa \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bc0\u0bb0\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 20-40%-\u0b90\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b8a\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"ats-applications-special-considerations\">ATS \u0bb5\u0bbf\u0ba3\u0bcd\u0ba3\u0baa\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bc1\u0b95\u0bcb\u0bb3\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bbe\u0bb0\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbe\u0ba4\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0ba9 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b9f\u0bcd\u0bb0\u0bbf\u0baa\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b87\u0bb1\u0ba8\u0bcd\u0ba4 \u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>&nbsp;(\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc8 \u0b86\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, 5-10 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0bae\u0bcd \u0ba4\u0ba3\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8)<\/li>\n\n\n\n<li>\u0b9c\u0bc6\u0ba9\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0bae\u0bcd \u2192 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baa\u0bcd \u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/strong>&nbsp;(\u0bae\u0bbf\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0b9a\u0bc2\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd: \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8 \u2192 \u0b85\u0ba4\u0bbf\u0b95 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u2192 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd: \u0b87\u0ba3\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u2192 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f ATS \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0bb1\u0ba8\u0bcd\u0ba4-\u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd: 5-10 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd (\u0b93\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9c\u0bc6\u0ba9\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc1\u0bae\u0bc8 \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd (\u0b85\u0ba4\u0bbf\u0b95\u0bbe\u0bb0\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0b92\u0ba9\u0bcd\u0bb1\u0ba9\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p>\u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd-\u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, 10-\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b9f\u0bc6\u0b9f\u0bcd-\u0baa\u0bb8\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd + \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf \u0baa\u0bbf\u0bb1\u0b95\u0bc1, ATS-\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 70% \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"572\" height=\"1024\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04.webp\" alt=\"\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0b83\u0baa\u0bbf\u0bb3\u0b95\u0bcd\u0bb8\u0bcd \u0bae\u0b99\u0bcd\u0b95\u0bbf\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b9f\u0bc6\u0b9f\u0bcd-\u0baa\u0bb8\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd ATS \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b83\u0baa\u0bcd\u0bb3\u0bcb\u0b9a\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd\" class=\"wp-image-2414\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04.webp 572w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04-168x300.webp 168w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/ats-transfer-sequence-inrush-minimization-flowchart-04-7x12.webp 7w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 4. ATS \u0b9f\u0bc6\u0b9f\u0bcd-\u0baa\u0bb8\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0baa\u0bbf\u0bb1\u0b95\u0bc1 5-10 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd, 80%-\u0b87\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2 \u0bb5\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baf \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. &lt;30%, \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9c\u0bc6\u0ba9\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc8 10-15\u00d7-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 3-5\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-troubleshooting-diagnosing-inrush-vs-genuine-faults\">\u0b95\u0bb3\u0baa\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd: \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd<\/h2>\n\n\n\n<p>\u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0bbf\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<p><strong>\u0b89\u0bb3\u0bcd\u0bb3\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 100-500 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0bae\u0bc1\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0b95\u0bc2\u0bae\u0bcd\u0baa\u0bc0\u0bb0 \u0b9a\u0bb0\u0bbf\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0b92\u0bb2\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bcd\u0b9a\u0bae\u0bcd 30-70%<\/li>\n\n\n\n<li>30-60 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf (\u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 (\u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8)<\/li>\n\n\n\n<li>\u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bb5\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd &lt;5%<\/li>\n\n\n\n<li>\u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf (\u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0b87\u0ba9\u0bcd\u0ba9\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0b9a\u0bc7\u0ba4\u0b9a\u0bcd \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd: \u0b8e\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0b9a\u0ba9\u0bc8, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0bcd, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba8\u0bcb\u0baf\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1 (\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95)<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0bbf\u0b95\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bbf\u0b9f\u0bbf \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bcb\u0baa\u0bcd<\/li>\n\n\n\n<li>\u0b89\u0bb3\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1 \u0b9a\u0ba8\u0bcd\u0ba4\u0bc7\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0b95\u0bb0\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 (DGA)<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b85\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, 10 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0baf\u0bbf\u0bb0\u0bcd \u0baa\u0bc6\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0b9f\u0bae\u0bcd\u0baa\u0bbf\u0b9f\u0bbf (0-2 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1: \u0918\u093e\u0924\u0940\u092f \u0bae\u0b99\u0bcd\u0b95\u0bb2\u0bcd + \u0b89\u0baf\u0bb0\u0bcd 2\u0bb5\u0ba4\u0bc1 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd = \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1; \u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd + \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd\u0bb8\u0bcd = \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8<\/h2>\n\n\n\n<p>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1, \u0ba4\u0bb1\u0bcd\u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0ba9 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2. \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bcb\u0bb0\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd, 0.1\u20130.5 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0918\u093e\u0924\u0940\u092f \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0b99\u0bcd\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd 8\u201315 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd-\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 &lt;5%, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 30\u201370%) \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb1\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p>\u0b90\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba9, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\/\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0ba9 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bae\u0bb0\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9: \u0b95\u0bbe\u0bb2 \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (\u0bae\u0bbf\u0b95 \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1), \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 (\u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1), \u0b85\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc1\u0ba9\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd (\u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8 \u0b89\u0baf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1), \u0bae\u0bc1\u0ba9\u0bcd-\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd (\u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0bbe\u0ba9 \u0b9a\u0ba8\u0bcd\u0ba4\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd (\u0baa\u0bb2-\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0b95\u0bcd\u0b95\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1). \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bae\u0bb2\u0bcd, \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8 85-95% \u0bb5\u0bb0\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0bb3\u0bcd\u0bb3\u0bb1\u0bbf\u0bb5\u0bc1: \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd (\u0b9a\u0bb0\u0bbf\u0baf\u0bc0\u0ba9\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd-\u0b95\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd) \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b8e\u0bb3\u0bbf\u0baf \u0b95\u0bbe\u0bb2-\u0ba4\u0bbe\u0bae\u0ba4 \u0b93\u0bb5\u0bb0\u0bcd\u0915\u0930\u0947\u0ba9\u0bcd\u0b9f\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b85\u0b9f\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba8\u0bb5\u0bc0\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd, \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0bbe\u0b9a\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9\u2014\u0b87\u0ba4\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8 \u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0bbf\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bbf, \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0bae\u0bbe\u0baf \u201c\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u201d \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b8a\u0bb4\u0bbf\u0baf\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb5\u0bbf\u0bb5\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker-ratings\/\">\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a>&nbsp;\u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0bbe\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/transformer-cooling-classes-onan-onaf-ofaf-guide\/\">\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0ba9\u0bcd\u0b95\u0bc2\u0bb2\u0bb0\u0bcd \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/a>.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1 \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0b95\u0bcb\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/599\" target=\"_blank\" rel=\"noopener\">IEC 60076 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-transformer-inrush--nuisance-trips\">\u0baa\u0bbf\u0bb1\u0bcd\u0b9a\u0bca\u0bb2\u0bcd\u0bb5\u0bbf\u0ba9\u0bbe: \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 0.5-2% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b8f\u0ba9\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 8-15 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8 \u0b8e\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0b95\u0bcb\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd B-H \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b85\u0ba4\u0bbf\u0b95 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bc1\u0b9f\u0ba9\u0bcd (\u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd 60-80%) \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf-\u0b95\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1, \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bc8 1.8 p.u.-\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bb3\u0bcd\u0bb3\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 1.2-1.3 p.u. \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4reshold-\u0b90 \u0bb5\u0bbf\u0b9f \u0bb5\u0bc6\u0b95\u0bc1 \u0ba4\u0bca\u0bb2\u0bc8\u0bb5\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0b9f\u0bc8\u0baf \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 B-H \u0b89\u0bb1\u0bb5\u0bc1 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b89\u0b9a\u0bcd\u0b9a\u0b95\u0b9f\u0bcd\u0b9f \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd = V_\u0bb5\u0bbf\u0ba3\u0bcd\u0ba3\u0bbf\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 \/ (X_\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd_\u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1), \u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0bb1\u0bcd\u0bb1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f 10-20\u00d7 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 8-15\u00d7 \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb0\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd 100-500 ms \u0bb5\u0bb0\u0bc8 \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd 30-70 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (50 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 100 \u0bb9\u0bc6\u0bb0\u0bcd\u0b9f\u0bcd\u0bb8\u0bcd), \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b95\u0bcb\u0bb0\u0bcd \u0b9a\u0bbe\u0b9a\u0bcd\u0b9a\u0bc1\u0bb0\u0bc7\u0bb7\u0ba9\u0bcd \u0b92\u0bb0\u0bc1 \u0b85\u0bb0\u0bc8-\u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b9a\u0bbe\u0b9a\u0bcd\u0b9a\u0bc1\u0bb0\u0bc7\u0b9f\u0bcd \u0b86\u0b95\u0bbf, \u0bae\u0bb1\u0bcd\u0bb1\u0bca\u0ba9\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5 \u0b9a\u0bae\u0b9a\u0bcd\u0b9a\u0bc0\u0bb0\u0bbf\u0ba9\u0bcd\u0bae\u0bc8 \u0b88\u0bb5\u0ba9\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd\u0bb8\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0b9f\u0bcd\u0b9f \u0b9a\u0bc8\u0ba9\u0bb8\u0bcd \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 (&gt;95% \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd, 15-20% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b85\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (inrush) \u0b8e\u0ba9 \u0bb5\u0b95\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, 0.5-1.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b99\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd &lt;5% \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0b8e\u0ba9\u0bb5\u0bc7 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b95 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd. \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4-\u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 85-95% \u0bb5\u0bb0\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0ba4\u0bc8 \u0b95\u0bb3 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc73: \u0b92\u0bb0\u0bc7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b9a\u0bbf\u0bb2 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bcd \u0b8f\u0ba9\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb1\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9: (1) \u0b95\u0bcb\u0bb0\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd\u2014CRGO \u0b9a\u0bbf\u0bb2\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bcd \u0b8e\u0b83\u0b95\u0bc1 60-80% \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf) vs amorphous \u0b89\u0bb2\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 30-50% (\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1); (2) \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u2014\u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0bae\u0b99\u0bcd\u0b95\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bbf\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9; (3) \u0b86\u0ba4\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd\u2014\u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bbe\u0ba9 \u0b86\u0ba4\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b89\u0b9a\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0b86\u0ba4\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bc8\u0bb5\u0bc0\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc8 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; (4) \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b95\u0bcb\u0ba3\u0bae\u0bcd\u2014\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 (\u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0bae\u0bcd) \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b89\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; (5) \u0b9a\u0bc1\u0bae\u0bc8 \u0bb5\u0bb0\u0bb2\u0bbe\u0bb1\u0bc1\u2014\u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9; (6) \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u2014\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 (80TP3T) \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb1\u0bcd\u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 30-80TP3T \u0bb5\u0bb0\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc74: \u0baa\u0bbf\u0bb4\u0bc8 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd (inrush) \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 (nuisance trips) \u0b8e\u0ba9\u0bcd\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9?<\/strong><\/p>\n\n\n\n<p>\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (\u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8): 15-18% \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd-\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (SEL \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd PCT2 = 18%, ABB-\u0b87\u0bb2\u0bcd 50H \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1). \u0b9f\u0bbf\u0b83\u0baa\u0bb0\u0ba9\u0bcd\u0bb7\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0bc8 0.25 pu-\u0b87\u0bb2\u0bcd (87P = 0.25), \u0bb8\u0bcd\u0bb2\u0bcb\u0baa\u0bcd\u0baa\u0bc8 35%-\u0b87\u0bb2\u0bcd (87S = 35%) \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc1 \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (&lt;100 ms) \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0baa\u0bbf\u0bb4\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd, 1.3-1.5\u00d7 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0b89\u0b9f\u0ba9\u0bcd 0.8-1.2 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba8\u0bbf\u0b9a\u0bcd\u0b9a\u0baf-\u0ba8\u0bc7\u0bb0 \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b87\u0ba4\u0bc1 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0baa\u0bbf\u0bb4\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf-\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (ATS, \u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd), \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd; \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0ba4\u0bbe\u0bae\u0ba4 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0baa\u0bbf\u0bb4\u0bc8 \u0b85\u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc75: \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0ba8\u0bc0\u0b95\u0bcd\u0b95, \u0baa\u0bbe\u0baf\u0bbf\u0ba3\u0bcd\u0b9f\u0bcd-\u0b86\u0ba9\u0bcd-\u0bb5\u0bc7\u0bb5\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbe\u0bae\u0bbe?<\/strong><\/p>\n\n\n\n<p>\u0b85\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc0\u0ba4\u0bbe\u0ba9 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 85-95% \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0b9a\u0bc0\u0bb0\u0bbe\u0ba9 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b93\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8). \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b93\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b93\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bbf \u00b11.0 p.u. \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0b9a\u0bc0\u0bb0\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 1.2 p.u. \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0b95\u0bc1 \u0b95\u0bc0\u0bb4\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd: (1) \u0b9a\u0bc0\u0bb0\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f VCB (\u00b12 ms \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bc1, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd); (2) \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf; (3) \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 5,000-15,000 TTP \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1. \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (&gt;5 MVA), \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd (\u0ba4\u0bbf\u0ba9\u0b9a\u0bb0\u0bbf \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1. \u0b85\u0bb0\u0bbf\u0ba4\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0ba4\u0bb2\u0bcd\u0bb2\u2014\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 90+ \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 &lt;10 \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0bb2\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc76: \u0b9a\u0bbf\u0bae\u0bcd\u0baa\u0ba4\u0bc6\u0b9f\u0bbf\u0b95\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9, \u0b85\u0ba4\u0bc1 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1, \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0ba3\u0bc8\u0baf\u0bbe\u0ba9 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0ba4\u0bc1\u0bb5\u0bc7 \u0b9a\u0bbf\u0bae\u0bcd\u0baa\u0ba4\u0bc6\u0b9f\u0bbf\u0b95\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (sympathetic inrush) \u0b8e\u0ba9\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8: \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd A \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 10\u00d7 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u2192 \u0bae\u0bc2\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bbe\u0bb2\u0bcd \u0baa\u0bc7\u0bb8\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd 5-15% \u0b9a\u0bb0\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0bb5\u0bc8 \u0b88\u0b9f\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bc1\u0bb2\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd B &amp; C \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0baa\u0bc7\u0bb8\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd = \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (A) + \u0b85\u0ba9\u0bc1\u0ba4\u0bbe\u0baa \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd (B+C), \u0b87\u0ba4\u0bc1 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd A-\u0bb5\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 1.2-1.5 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bc2\u0b9f, \u0b87\u0ba4\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd. \u0ba4\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1: \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0bb2\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd, \u0ba8\u0bc7\u0bb0-\u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 1.5-2.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 30-60 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbe\u0bae\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0ba9\u0bcd\u0bb1\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc77: \u0b92\u0bb0\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0bb5\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0b85\u0bb2\u0bc8\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd:&nbsp;<strong>\u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bca\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/strong>&nbsp;100-500 ms-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0918\u093e\u0924\u0940\u092f \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1, 30-70% \u0b9a\u0bc6\u0b95\u0ba3\u0bcd\u0b9f\u0bcd-\u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u094b\u0928\u0bbf\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 500 ms-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1, 30-60 s \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb0\u0bae\u0bbe\u0b95 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bb2\u0bcd (\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bc1\u0bb2\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1).&nbsp;<strong>\u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bca\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/strong>&nbsp;\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8), 1000 M\u03a9 \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3), \u0b89\u0bb3\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b95\u0bb0\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 (DGA), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/p>","protected":false},"excerpt":{"rendered":"<p>Transformer energization creates the most common nuisance trip condition in medium-voltage distribution systems. The magnetic core must establish flux when voltage is applied, and if switching occurs near voltage zero-crossing, the flux waveform becomes asymmetric\u2014driving the core into deep saturation. Magnetizing current skyrockets from its normal 0.5-2% of rated load to 8-15\u00d7 transformer full-load current, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2411,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-2409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2409"}],"version-history":[{"count":4,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2409\/revisions"}],"predecessor-version":[{"id":3562,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2409\/revisions\/3562"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2411"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2409"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}