{"id":2425,"date":"2026-01-04T05:56:04","date_gmt":"2026-01-04T05:56:04","guid":{"rendered":"https:\/\/xbrele.com\/?p=2425"},"modified":"2026-04-07T13:47:11","modified_gmt":"2026-04-07T13:47:11","slug":"vcb-timing-test-travel-curves-interruption-reliability","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/vcb-timing-test-travel-curves-interruption-reliability\/","title":{"rendered":"\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd: \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd"},"content":{"rendered":"<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd (VCB) \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0ba4\u0ba9\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0ba8\u0b95\u0bb0\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0b87\u0ba4\u0bc1 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb4\u0bc8\u0baf\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbe\u0bb2\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba9\u0bc1\u0bae\u0bbe\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. 40 \u0bae\u0bbf.\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 VCB, \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95 60 \u0bae\u0bbf.\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bcb\u0b9a\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bb2\u0bbe\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bc7\u0b95\u0bae\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb5\u0bbe, \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb5\u0bbe, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0b9a\u0b95\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0906\u0935\u0927\u093f\u0915\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0baf\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b9a\u0b95\u0bcd\u0ba4\u0bbf\u0baf\u0bb3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0bc0\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0bb8\u0bcd\u0b95\u0bcb\u0baa\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 35 ms-\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 50 ms-\u0b87\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf\u0baf\u0bbe? \u0b87\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bbe? \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bbe? \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bbe\u0bae\u0bb2\u0bcd <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 62271-100<\/a> \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bc7\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b87\u0baf\u0bb1\u0bcd\u0baa\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b89\u0bb1\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bbe\u0bae\u0bb2\u0bcd, \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc8 \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 (\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0b95\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1) \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc8 (\u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bbf\u0bb2\u0bcd \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1) \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf VCB \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd, IEC \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0bb5\u0bbf\u0bb2\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bb3\u0baa\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0bb1\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd: \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/9AU5AGaDwtY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-opening-time-affects-interruption-capability\">\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b8f\u0ba9\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 VCB \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0b8f\u0ba4\u0bc7\u0ba9\u0bc1\u0bae\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd: (1) \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 (2) \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8 \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1. IEC 62271-100, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc0\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc8 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 30-50 ms) \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/strong>:<br>t<sub>\u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4<\/sub>\u00a0= t<sub>\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1<\/sub>\u00a0+ t<sub>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/sub>\u00a0+ t<sub>\u0bb5\u0bb3\u0bc8\u0bb5\u0bc1<\/sub><br><br>\u2022\u00a0<strong>t<sub>\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1<\/sub><\/strong>: \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0baa\u0bc6\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u2192 \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (5-15 \u0bae\u0bbf.\u0bb5\u0bbf)<br>\u2022\u00a0<strong>t<sub>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/sub><\/strong>: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0b95\u0bb0\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u2192 \u0bae\u0bc1\u0bb4\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 (15-30 \u0bae\u0bbf.\u0bb5\u0bbf)<br>\u2022\u00a0<strong>t<sub>\u0bb5\u0bb3\u0bc8\u0bb5\u0bc1<\/sub><\/strong>: \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u2192 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd + \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0bb4\u0bbf\u0bb5\u0bc1 (5-10 \u0bae\u0bbf.\u0bb5\u0bbf)<br>\u0bae\u0bca\u0ba4\u0bcd\u0ba4\u0bae\u0bcd: \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 12 kV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 25-55 ms<\/p>\n\n\n\n<p><strong>\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0ba4\u0bbf\u0bb0\u0b9f\u0bcd\u0b9a\u0bbf<\/strong>: 12 kV-\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd 25 kA \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd ~50 kW \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd 35 ms-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 50 ms-\u0b86\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bb5\u0bbf\u0bb2\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd 1.75 kJ-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 2.5 kJ-\u0b86\u0b95 \u0b89\u0baf\u0bb0\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (+43%)\u2014\u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf, \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>IEC 62271-100-\u0baa\u0b9f\u0bbf \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8<\/strong>: \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u2264 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 + 10%. 40 ms \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1, 44 ms \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1; 48 ms-\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/p>\n\n\n\n<p>\u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/what-is-vacuum-circuit-breaker-working-principle\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/a>&nbsp;\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bb3\u0bb5\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bc2\u0bb4\u0bb2\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01.webp\" alt=\"\u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0bcb\u0b9f\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd, VCB \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8, \u0b85\u0ba4\u0bbe\u0bb5\u0ba4\u0bc1 \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.\" class=\"wp-image-2428\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-opening-sequence-timing-phases-diagram-01-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 1. VCB \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0bb2\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8: \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1 (5-15 ms), \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 (15-30 ms), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (5-10 ms) \u0b8e\u0ba9 \u0bae\u0bca\u0ba4\u0bcd\u0ba4\u0bae\u0bcd 25-55 ms. IEC 62271-100 \u0b86\u0ba9\u0ba4\u0bc1, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u2264\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 +10% \u0b8e\u0ba9 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact-travel-curve-anatomy-interpreting-position-vs-time\">\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b89\u0b9f\u0bb1\u0bcd\u0b95\u0bc2\u0bb1\u0bc1: \u0ba8\u0bbf\u0bb2\u0bc8 vs \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bb0\u0bc8<\/h2>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1, \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 (\u0b9a\u0bc6\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0b9a\u0bcd\u0b9a\u0bc1, \u0bae\u0bbf\u0bae\u0bc0) \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 ( \u0b95\u0bbf\u0b9f\u0bc8\u0bae\u0b9f\u0bcd\u0b9f \u0b85\u0b9a\u0bcd\u0b9a\u0bc1, \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf) \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b86\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bbf\u0b9a\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>: \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0baa\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd (0-10 \u0bae\u0bbf.\u0bb5\u0bbf)<\/li>\n\n\n\n<li><strong>\u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/strong>: \u0bb5\u0b9a\u0ba8\u0bcd\u0ba4\u0b95\u0bbe\u0bb2\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (10-20 ms)<\/li>\n\n\n\n<li><strong>\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bc7\u0b95\u0bae\u0bcd<\/strong>: \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1, \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b87\u0ba9\u0bcd\u0ba9\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8 (20-30 ms)<\/li>\n\n\n\n<li><strong>\u0bb5\u0bc7\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bbf, \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bbf\u0bb2\u0bcd (30-40 \u0bae\u0bbf.\u0bb5\u0bbf) \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8<\/strong>: \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (40-45 \u0bae\u0bbf.\u0bb5\u0bbf)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 12 kV VCB \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<br>\u2022\u00a0<strong>\u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb0\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>: 10-14 \u0bae\u0bbf\u0bae\u0bc0 (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc2\u0bb0\u0bae\u0bcd)<br>\u2022\u00a0<strong>\u0b89\u0b9a\u0bcd\u0b9a \u0bb5\u0bc7\u0b95\u0bae\u0bcd<\/strong>: 0.8-1.2 \u0bae\u0bc0\/\u0bb5\u0bbf (60-70% \u0bb8\u0bcd\u0b9f\u0bcd\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b85\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1)<br>\u2022\u00a0<strong>\u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf \u0bb5\u0bc7\u0b95\u0bae\u0bcd<\/strong>: 0.5-0.7 \u0bae\u0bc0\/\u0bb5\u0bbf (\u0ba4\u0bc1\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \/ \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<br>\u2022\u00a0<strong>\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b88\u0b9f\u0bc1\u0baa\u0bbe\u0b9f\u0bc1<\/strong>: \u0baa\u0b95\u0bcd\u0b95\u0bb5\u0bbe\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0bc8\u0b9a\u0bbf 20-30%<br>IEC 62271-100 \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8\u2014\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb0\u0bcd.<\/p>\n\n\n\n<p><strong>\u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bb5\u0bbf\u0bb2\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong>: \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd (\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8)<\/li>\n\n\n\n<li><strong>\u0bb5\u0bc7\u0b95 \u0bae\u0bc1\u0ba9\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd (\u0baa\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0bbf\u0ba9\u0bc8)<\/li>\n\n\n\n<li><strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0ba8\u0bcd\u0ba4\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8<\/strong>: \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b9a\u0bc7\u0ba4 \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbe\u0bb0\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8 (\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 \u0ba4\u0bc2\u0bb0\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8)<\/li>\n<\/ul>\n\n\n\n<p>10-20 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 120 VCB-\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, 25%-\u0bb2\u0bcd \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 (\u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8), 15%-\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb8\u0bcd\u0b9f\u0bb0\u0bcb\u0b95\u0bcd (&lt;\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 90%), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 8%-\u0bb2\u0bcd IEC +10% \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bae\u0bc0\u0bb1\u0bbf\u0baf \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02.webp\" alt=\"\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 VCB \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 S-\u0bb5\u0b9f\u0bbf\u0bb5\u0ba4\u0bcd\u0ba4\u0bc8, \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb8\u0bcd\u0b9f\u0bb0\u0bcb\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bc0\u0bb0\u0bcd\u0b95\u0bc1\u0bb2\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2430\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-travel-curve-normal-vs-degraded-comparison-02-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 2. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1: \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 (\u0b87\u0b9f\u0ba4\u0bc1) 1.0 \u0bae\u0bc0\/\u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b89\u0b9a\u0bcd\u0b9a \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0ba8\u0bcd\u0ba4\u0b95\u0ba4\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b9a\u0bbf\u0ba4\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 (\u0bb5\u0bb2\u0ba4\u0bc1) \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd), \u0bb5\u0bc7\u0b95 \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd (\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1), \u0bae\u0ba8\u0bcd\u0ba4\u0b95\u0ba4\u0bbf \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 (\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1).<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"field-test-procedure-equipment-and-measurement\">\u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8: \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/h2>\n\n\n\n<p>\u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\/\u0b95\u0bcd\u0bb3\u0bcb\u0bb8\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd DC \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bc1\u0ba3\u0bc8 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0434\u044e\u0b9a\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0b9a\u0bc6\u0b95\u0ba3\u0bcd\u0b9f\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf<\/strong>\u00a0(\u0b92\u0bae\u0bbf\u0b95\u0bcd\u0bb0\u0bbe\u0ba9\u0bcd CB-1, \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bb0\u0bcd EZCT-2000, \u0b9f\u0bcb\u0baa\u0bbf\u0bb3\u0bcd TDR-500): DC \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd, \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1, \u0baa\u0baf\u0ba3 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bbf \u0b87\u0b9f\u0bc8\u0bae\u0bc1\u0b95\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li><strong>\u0baa\u0baf\u0ba3 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf<\/strong>: \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0ba3\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0bca\u0b9f\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0bb7\u0bbf\u0baf\u0bcb\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0baa\u0bcd\u0b9f\u0bbf\u0b95\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0b95\u0bcb\u0b9f\u0bb0\u0bcd (\u0b87\u0b9f\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li><strong>\u0b89\u0ba4\u0bb5\u0bbf\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/strong>: \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0baf\u0bc2\u0b9a\u0bb0\u0bc8 \u0bb5\u0bbf\u0b9f\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b8e\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8<\/strong>:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-1-safety-and-preparation-10-minutes\">\u0baa\u0b9f\u0bbf 1: \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (10 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0baf\u0ba3 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0baf\u0bc2\u0b9a\u0bb0\u0bc8 \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0ba3\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0b85\u0ba9\u0bb2\u0bc8\u0b9a\u0bb0\u0bbf\u0ba9\u0bcd DC \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0b9f\u0bcd\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0bae\u0bc1\u0ba9\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0b89\u0ba4\u0bb5\u0bbf\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf \u0b89\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (NO \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd NC \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-2-initial-trip-test-5-minutes\">\u0baa\u0b9f\u0bbf 2: \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (5 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8 \u0bae\u0bc2\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0baf\u0ba3\u0b95\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd\u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u2192 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd (0-100 \u0bae\u0bbf.\u0bb5\u0bbf. \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 vs \u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u2264 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f + 10%, \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-3-voltage-variation-test-15-minutes\">\u0baa\u0b9f\u0bbf 3: \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (15 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h3>\n\n\n\n<p>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 80%, 100%, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 110%-\u0b87\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. IEC 62271-100, 70-110% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1<\/strong>:<br>\u2022 110% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd: \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd 5-10% \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0b9a\u0bc8, \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9 \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1)<br>\u2022 80% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd: \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd 10-15% \u0bb5\u0bb0\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0b9a\u0bc8, \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1)<br>\u2022 70% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd: \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bb2\u0bbe\u0bae\u0bcd (\u0bb2\u0bbe\u0b95\u0bcd-\u0b90 \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0b9a\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bbe\u0bb2\u0bcd)<br>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 20%-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bae\u0bcd\u0baa\u0bbf \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-4-close-operation-test-5-minutes\">\u0baa\u0b9f\u0bbf 4: \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd (5 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h3>\n\n\n\n<p>\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd (20-35 ms), \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1\u2014\u0b85\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-5-multi-operation-test-30-minutes\">\u0baa\u0b9f\u0bbf 5: \u0baa\u0bb2-\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (30 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/h3>\n\n\n\n<p>30 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0b95 10 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bc1-\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>10 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd 5 \u0bae\u0bbf.\u0bb5\u0bbf-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd: \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bc8 (\u0b89\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1)<\/li>\n\n\n\n<li>\u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0baf\u0bae\u0bbe\u0ba4\u0bb2\u0bcd (\u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bbe\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bb2\u0bcd)<\/li>\n<\/ul>\n\n\n\n<p>\u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vcb-fat-sat-acceptance-test-checklist\/\">\u0bb5\u0bbf\u0b9a\u0bbf\u0baa\u0bbf \u0b8e\u0b83\u0baa\u0bcd\u0b8f\u0b9f\u0bbf\/\u0b9a\u0bbe\u0b9f\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03.webp\" alt=\"\u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b85\u0ba9\u0bb2\u0bc8\u0b9a\u0bb0\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0b89\u0ba3\u0bb0\u0bbf\u0baf\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd VCB \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" class=\"wp-image-2427\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-field-test-equipment-setup-wiring-diagram-03-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 3. \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1: VCB \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf, \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd (\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 DC \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd), \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf (\u0b87\u0b9f\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. IEC 62271-100 \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf 80%, 100%, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 110% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"troubleshooting-timing-deviations-root-causes-and-fixes\">\u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0bb5\u0bbf\u0bb2\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd: \u0bae\u0bc2\u0bb2 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd, \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe (\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0b9a\u0b95\u0bc1), \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe (\u0b95\u0bbe\u0baf\u0bcd\u0bb2\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1, \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0bcd), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0ba8\u0bcb\u0baf\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0bae\u0bb0\u0bae\u0bcd<\/strong>:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-1-opening-time-10-20-slower-than-rated\">\u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf 1: \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f 10-20% \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1<\/h3>\n\n\n\n<p><strong>\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd<\/strong>\u0baa\u0bb4\u0bc8\u0baf\u0ba4\u0bc1\/\u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b83\u0baa\u0bcb\u0bb0\u0bcd\u0bb8\u0bcd \u0b95\u0bc7\u0b9c\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (\u0b9f\u0bc7\u0b9f\u0bcd\u0b9f\u0bbe\u0bb7\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u00b110% \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b85\u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bbf\u0bb3\u0bbf\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/strong>: \u0b89\u0bb2\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb4\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0b9a\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>: \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0b9a\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb3\u0bcd \u0b89\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd, \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0b89\u0ba3\u0bb0\u0bcd<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0baa\u0bc2\u0b9a\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bcb\u0bb2\u0bbf\u0baa\u0bcd\u0b9f\u0bbf\u0ba9\u0bae\u0bcd \u0b9f\u0bc8\u0b9a\u0bb2\u0bcd\u0baa\u0bc8\u0b9f\u0bc1 \u0b95\u0bbf\u0bb0\u0bc0\u0bb8\u0bcd)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>: \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0ba4\u0bc1 (\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0bb5\u0b95\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8)\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>: \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bc7\u0baf\u0bc7 \u0bae\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0bbf\u0b95 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbf\u0bb2\u0bcd \u0b87\u0baf\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd)<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bbf\u0b9a\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-2-opening-time-varies-15-between-operations\">\u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf 2: \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd &gt;15% \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/h3>\n\n\n\n<p><strong>\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd<\/strong>: \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bbf\u0ba9\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>\u0b95\u0bc1\u0bb4\u0bbf\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0b86\u0baf\u0bcd\u0bb5\u0bc1<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>: \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd<\/strong>: \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>: \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0bc2\u0b9f\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd &lt;15% \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>: 20%-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"symptom-3-travel-curve-shows-no-dashpot-deceleration\">\u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf 3: \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0ba8\u0bcd\u0ba4\u0b95\u0ba4\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8<\/h3>\n\n\n\n<p><strong>\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1<\/strong>\u0baa\u0bbf\u0bb8\u0bcd\u0b9f\u0ba9\u0bcd \u0b9a\u0bc0\u0bb2\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1, \u0bae\u0ba8\u0bcd\u0ba4\u0ba8\u0bbf\u0bb2\u0bc8 \u0b87\u0bb4\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b8e\u0b9a\u0bcd\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0b86\u0baf\u0bcd\u0bb5\u0bc1<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>\u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b9a\u0bc0\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1<\/strong>\u0baa\u0bbf\u0bb8\u0bcd\u0b9f\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0b88\u0b9f\u0bc1\u0baa\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>: \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc8\u0baf\u0bc7\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1<\/strong>:<br>\u2022\u00a0<strong>\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd<\/strong>: 80-110% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bc0\u0bb0\u0bbe\u0ba9\u0ba4\u0bc1, \u0b9a\u0bbf\u0bb1\u0bbf\u0ba4\u0bb3\u0bb5\u0bc1 \u0bae\u0b9a\u0b95\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8<br>\u2022\u00a0<strong>\u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/strong>: \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd 110-125% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\/\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8<br>\u2022\u00a0<strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1<\/strong>: \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd &gt;125% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, \u0baa\u0bb2 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd (\u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd + \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd + \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n\n\n\n<p>85 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, 70% \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9, 20% \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 10% \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"relationship-between-closing-time-and-contact-bounce\">\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b89\u0bb1\u0bb5\u0bc1<\/h2>\n\n\n\n<p>\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 20-35 ms) \u0b85\u0b9f\u0bc8\u0bb5\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0b87\u0ba4\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1. \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bca\u0bb3\u0bbf \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 (\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd) \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc7\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>IEC 62271-100, \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc2\u0b9f\u0bb2\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u22650.3 \u0bae\u0bbf\u0bae\u0bc0 \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 '\u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd' \u0b8e\u0ba9 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bb5\u0bc0\u0ba9 VCB-\u0b95\u0bb3\u0bcd, \u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bc8 &lt;0.1 \u0bae\u0bbf\u0bae\u0bc0-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95 \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0bbe\u0bb2\u0bbf\u0b95\u0bcd \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0baa\u0b83\u0baa\u0bcd\u0baa\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b89\u0baf\u0bb0\u0bcd \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bbf\u0bb2\u0bcd (\u226510 kHz \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd) \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bc1\u0ba4\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b87\u0b9f\u0bae\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bc1\u0bb5\u0ba4\u0bc1 \u0ba8\u0bbf\u0ba9\u0bcd\u0bb1\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0b8e\u0ba8\u0bcd\u0ba4\u0bb5\u0bca\u0bb0\u0bc1 \u0baa\u0ba4\u0bb5\u0bbf \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc8\/\u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0baa\u0bb5\u0bc1\u0ba9\u0bcd\u0bb8\u0bcd \u0ba4\u0bc2\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>:<br>\u2022\u00a0<strong>\u0ba4\u0bc2\u0bb0\u0bae\u0bcd<\/strong>: &lt;0.3 \u0bae\u0bbf\u0bae\u0bc0 (IEC \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1), &lt;0.1 \u0bae\u0bbf\u0bae\u0bc0 (\u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b86\u0baf\u0bc1\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1)<br>\u2022\u00a0<strong>\u0b95\u0bbe\u0bb2\u0bae\u0bcd<\/strong>: &lt;2 ms (\u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0bb2\u0bae\u0bcd \u2192 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bc1\u0ba9\u0bcd-\u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd)<br>\u2022\u00a0<strong>\u0b8e\u0ba3\u0bcd\u0ba3\u0bc1<\/strong>: \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1, \u0baa\u0bb2\u0bae\u0bc1\u0bb1\u0bc8 \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0bae\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0bb5\u0b9a\u0ba8\u0bcd\u0ba4\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (\u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd)<\/li>\n\n\n\n<li>\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0ba8\u0bcd\u0ba4\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 (\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb0\u0bb5\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8)<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (\u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb3\u0bcd\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba4\u0bca\u0b9f\u0bc1\u0ba4\u0bb2\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9)<\/li>\n<\/ul>\n\n\n\n<p>60 VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bc6\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bb3\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bcd, \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9: \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf 0.05 \u0bae\u0bbf\u0bae\u0bc0, 10 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf 0.15 \u0bae\u0bbf\u0bae\u0bc0, 20 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf 0.35 \u0bae\u0bbf\u0bae\u0bc0 (IEC \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1). \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0baa\u0bc1\u0ba9\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bc8 0.1 \u0bae\u0bbf\u0bae\u0bc0-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04.webp\" alt=\"IEC 62271-100 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd 0.2 \u0bae\u0bbf\u0bae\u0bc0 \u0b85\u0bb2\u0bc8\u0ba8\u0bc0\u0bb3\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f VCB \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-2426\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/vcb-closing-travel-curve-contact-bounce-measurement-04-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u0baa\u0b9f\u0bae\u0bcd 4. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1: 25 ms-\u0bb2\u0bcd \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0b85\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 0.2 mm \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd (1.5 ms \u0b95\u0bbe\u0bb2\u0bae\u0bcd)\u2014IEC 62271-100 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd<0.3 mm). Excessive bounce (>0.3 \u0bae\u0bbf\u0bae\u0bc0) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0ba4\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"timing-test-frequency-and-recordkeeping\">\u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n\n\n\n<p>IEC 62271-100 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd IEEE C37.09 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b9a\u0bc7\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf, \u0b95\u0bbe\u0bb2\u0bae\u0bc1\u0bb1\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0ba3\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0baf\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>: \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1 \u0ba8\u0bc7\u0bb0 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/li>\n\n\n\n<li><strong>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bae\u0bcd (\u0bae\u0bc1\u0ba4\u0bb2\u0bcd 5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>: \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (\u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8)<\/li>\n\n\n\n<li><strong>\u0b87\u0bb0\u0bc1\u0baa\u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1 (6-15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>: \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\/\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd + \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li><strong>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 (&gt;15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0ba9\u0bb0\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1)<\/strong>: \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb2-\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b89\u0b9f\u0bcd\u0baa\u0b9f \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0ba4\u0bbf\u0bb5\u0bc7\u0b9f\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/strong>: \u0b95\u0bbe\u0bb2\u0baa\u0bcd\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd 32 ms (\u0baa\u0bc1\u0ba4\u0bbf\u0baf\u0ba4\u0bc1) \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 38 ms (10 \u0b86\u0bae\u0bcd \u0b86\u0ba3\u0bcd\u0b9f\u0bc1) \u0bb5\u0bb0\u0bc8 44 ms (15 \u0b86\u0bae\u0bcd \u0b86\u0ba3\u0bcd\u0b9f\u0bc1) \u0b86\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd, \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b85\u0ba4\u0bc1 48 ms (\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 40 ms \u0b95\u0bca\u0ba3\u0bcd\u0b9f 120%) \u0b90\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/strong>\u0ba8\u0bb5\u0bc0\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd (SEL-487V, ABB REM615) \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\/\u0bae\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 (\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bc1\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd). \u0b87\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0ba8\u0bc7\u0bb0\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd 40 VCB-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcb\u0bae\u0bcd; 6 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (15%) \u0b95\u0bbe\u0bb2\u0ba4\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9, \u0b85\u0bb5\u0bc8 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0b9f\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 12-18 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u2014\u0b87\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bcb\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vacuum-interrupter-contact-wear-replacement-guide\/\">VCB \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2 \u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/a>.<\/p>\n\n\n<p>\u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0bc6\u0bb1\u0bc1\u0ba4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0b9f\u0bc8\u0bae\u0bc1\u0b95\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/drawout-vcb-racking-safety-shutters-alignment-checks\/\">\u0b87\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VCB \u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b99\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd<\/a>&nbsp;\u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0906\u0935\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0ba9 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1.<\/p>\n\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8<\/h2>\n\n\n\n<p>VCB \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd IEC 62271-100 \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b87\u0ba4\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb3\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bbe\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 30-50 ms) \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 +10%-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (&gt;2 kJ \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd). \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b86\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0b95\u0bae\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd (IEC-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf &lt;0.3 \u0bae\u0bbf\u0bae\u0bc0, &lt;0.1 \u0bae\u0bbf\u0bae\u0bc0 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1) \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd, 80-110% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf \u0baa\u0bb2-\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba8\u0bc7\u0bb0 \u0bb5\u0bbf\u0bb2\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bcb\u0baf\u0bb1\u0bbf\u0ba4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0b89\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 (\u0baa\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd, \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0ba8\u0bc7\u0bb0 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0b9f\u0bc8\u0ba4\u0bb2\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bbf\u0bb0\u0bb5\u0b95\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b89\u0bb3\u0bcd\u0bb3\u0bb1\u0bbf\u0bb5\u0bc1: \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. 10 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd 35 ms-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 42 ms-\u0b86\u0b95 \u0bae\u0bbe\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd, \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0bb5\u0b9a\u0bb0\u0bae\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd (\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd) \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 \u0b85\u0bb5\u0bcd\u0bb5\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bbe\u0ba4 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, VCB \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 (\u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0b95\u0bcd\u0b95 (\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bc6\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1) \u0b86\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b87\u0ba4\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0baf\u0bc2\u0bb1\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq-vcb-timing-test--travel-curves\">\u0baa\u0bbf\u0bb1\u0bcd\u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc8: VCB \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: IEC 62271-100-\u0b87\u0ba9\u0bcd \u0baa\u0b9f\u0bbf, 40 ms \u0b8e\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1 VCB-\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong><\/p>\n\n\n\n<p>IEC 62271-100, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd 110% \u0bb5\u0bb0\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 40 ms \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u226444 ms \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1. 44-48 ms (110-120%) \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc8 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b85\u0ba8\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd, \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd. 48 ms-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (&gt;120%) \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd = \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (\u0b9f\u0bcd\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u2192 \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1, 5-15 ms) + \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (\u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u2192 \u0bae\u0bc1\u0bb4\u0bc1 \u0ba8\u0bc0\u0bb3\u0bae\u0bcd, 15-30 ms) + \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (5-10 ms). \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, 120% \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd (&gt;2.5 kJ, 25 kA-\u0b87\u0bb2\u0bcd &lt;2.0 kJ \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1) \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0baa\u0bbf\u0bb4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 3-5 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1, \u0b9f\u0bbe\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b92\u0bb0\u0bc1 \u0b86\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: (1) \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, 0-60% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd), (2) \u0ba8\u0bbf\u0bb2\u0bc8\u0bb5\u0bc7\u0b95\u0bae\u0bcd (\u0b89\u0b9a\u0bcd\u0b9a \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, 60-80% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd), (3) \u0bae\u0ba8\u0bcd\u0ba4\u0bae\u0bcd (\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, 80-100% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd). \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bbe\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bcb\u0ba9\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bb5\u0bb0\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba4\u0bc1 10-20 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0ba4\u0bbe\u0b95\u0bcd\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bc8 (\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b89\u0b9f\u0ba9\u0bcd 50-100 N \u0b89\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 500-1000 N) \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 (\u0b9a\u0bc0\u0bb2\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1), \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bbe\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 (\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bcd), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 (\u0baa\u0bbf\u0bb8\u0bcd\u0b9f\u0ba9\u0bcd \u0b88\u0b9f\u0bc1\u0baa\u0b9f\u0bbe\u0ba4\u0ba4\u0bc1). \u0b87\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc0\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b9a\u0bbf\u0bb2\u0bbf\u0b95\u0bbe\u0ba9\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd, 100-500 cSt \u0baa\u0bbe\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8) \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. 10-20 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 120 VCB-\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0ba4\u0bbf\u0bb2\u0bcd, 25%-\u0b87\u0bb2\u0bcd \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bb5\u0bc7\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bc1 \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc73: 80% \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 VCB-\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b8f\u0ba9\u0bcd 10-15% at \u0b86\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0b9a\u0bc8 F \u221d (I_coil)\u00b2 \u221d (V \/ R)\u00b2. 80% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0bb5\u0bbf\u0b9a\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd (0.8)\u00b2 = 64% \u0b86\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0b9a\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0bb2\u0bbe\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b87\u0bb4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bb5\u0bc6\u0bb2\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b88\u0b9f\u0bc1\u0b95\u0b9f\u0bcd\u0b9f, IEC 62271-100 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8 70-110TP3T \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb0\u0bae\u0bbe\u0b95 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 110% \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 80% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd &gt;20% \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b9a\u0ba8\u0bcd\u0ba4\u0bc7\u0b95\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8: (1) \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (\u0b85\u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd), (2) \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0b89\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0b88\u0b9f\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1), (3) \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bb5\u0bb2\u0bc1\u0bb5\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 (\u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0bbf\u0b95\u0bcd\u0b95 \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0b9a\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1). \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 10-15% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. 70%, 80%, 100%, 110% \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd; 70%-\u0b87\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd 80-110%-\u0b87\u0bb2\u0bcd \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0b9a\u0bcd \u0b9a\u0bc0\u0bb0\u0bb4\u0bbf\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc74: \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd, \u0b85\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1?<\/strong><\/p>\n\n\n\n<p>\u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd, \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\/\u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bae\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bc6\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1 \u0b95\u0ba3\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 (0.1-0.5 \u0bae\u0bbf\u0bae\u0bc0, 1-3 \u0bae\u0bbf\u0bae\u0bc0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b95\u0bbe\u0bb2\u0bae\u0bcd) \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bbe\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u2192 \u0b87\u0ba4\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b92\u0b9f\u0bcd\u0b9f\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd\u0bb5\u0bbf\u0bb4\u0bbf\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. IEC 62271-100 \u0bb5\u0bbf\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf, \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0b9a\u0bc8 0.3 \u0bae\u0bbf\u0bae\u0bc0-\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd; \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 (&gt;10,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd), 0.1 \u0bae\u0bbf\u0bae\u0bc0-\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc7 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd: \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bc0\u0ba4\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bbf\u0b9a\u0bc8 (\u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd), \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0bae\u0ba8\u0bcd\u0ba4\u0ba8\u0bbf\u0bb2\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bc8 (\u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb0\u0bb5 \u0baa\u0bbe\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8 (\u0b95\u0bc1\u0bb4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bae\u0bae\u0bbe\u0b95 \u0b85\u0bae\u0bc8\u0baf\u0bbe\u0ba4\u0bc1). \u0b89\u0baf\u0bb0\u0bcd-\u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 (\u226510 kHz \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd) \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd; \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf: \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0b9f\u0bc7\u0bb8\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc6\u0bb0\u0bc1\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc75: \u0b92\u0bb0\u0bc1 VCB-\u0baf\u0bbf\u0ba9\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd, \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><\/p>\n\n\n\n<p>\u0b95\u0b9f\u0bae\u0bc8 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd: (1)&nbsp;<strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>&nbsp;\u2013 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0bae\u0bc1\u0bb4\u0bc1 \u0ba8\u0bc7\u0bb0 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1; (2)&nbsp;<strong>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 (0-5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>&nbsp;\u2013 \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7; (3)&nbsp;<strong>\u0b87\u0bb0\u0bc1\u0baa\u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1 (6-15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>&nbsp;\u2013 \u0ba4\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1\/\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd; (4)&nbsp;<strong>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 (&gt;15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0ba9\u0bb0\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 &gt;\u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 1000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/strong>&nbsp;\u2013 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 10-\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b89\u0b9f\u0bcd\u0baa\u0b9f \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1. IEC 62271-100 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd IEEE C37.09 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 2,000-5,000 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 (10-15 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0ba8\u0bb5\u0bc0\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd (SEL-487V, ABB REM615) \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0ba8\u0bc7\u0bb0\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0bb0\u0bc1\u0ba3\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b8e\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd 12-18 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7, \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0bb5\u0b9a\u0bb0\u0b95\u0bbe\u0bb2 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc76: VCB \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/strong><\/p>\n\n\n\n<p>\u0bae\u0bb1\u0bc8\u0bae\u0bc1\u0b95\u0bae\u0bbe\u0b95 \u0b86\u0bae\u0bcd\u2014\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba4\u0bc2\u0bb0\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc8 \u0b85\u0b9f\u0bc8\u0baf \u0ba8\u0b95\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd), \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bb5\u0bbf\u0b9a\u0bc8 \u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0b9f\u0bc8\u0baf\u0bb2\u0bbe\u0bae\u0bcd. \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f 10-20% \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0b9a\u0bb2\u0bcd \u0ba4\u0b9f\u0bbf\u0bae\u0ba9\u0bbf\u0bb2\u0bcd &gt;30% \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 &gt;500 \u00b5\u03a9 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe \u0b8e\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 (\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd), \u0baa\u0bb3\u0bcd\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd\/\u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0b86\u0baf\u0bcd\u0bb5\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b8e\u0b95\u0bcd\u0bb8\u0bcd-\u0b95\u0ba4\u0bbf\u0bb0\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 (\u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bbe\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8) \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0ba8\u0bc7\u0bb0\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0b85\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0b95 3 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 1-2 ms \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 2-3 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1 (\u0ba8\u0bc7\u0bb0\u0bae\u0bcd + \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 + \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8) 85-90% \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 (60-70% \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bcd) \u0b87\u0ba4\u0bc1 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc77: \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f 25% \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bc8 \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><\/p>\n\n\n\n<p>\u0bae\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bcb\u0baf\u0bb1\u0bbf\u0ba4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd: (1)&nbsp;<strong>\u0b85\u0bb3\u0bb5\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong>&nbsp;\u2013 \u0baa\u0baf\u0ba3 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0baf\u0bc2\u0b9a\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bc1\u0ba3\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bbe\u0ba9\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0baf\u0bc2\u0b9a\u0bb0\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd (\u00b15 ms) \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bbe \u0b8e\u0ba9\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd; (2)&nbsp;<strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>&nbsp;\u2013 80%, 100%, 110% \u0b8e\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd; \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bbe\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 (\u0baa\u0bb2\u0bb5\u0bc0\u0ba9\u0bae\u0bbe\u0ba9 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b89\u0bb0\u0bbe\u0baf\u0bcd\u0bb5\u0bc1); \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd\/\u0bb2\u0bbe\u0b95\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0ba8\u0bcd\u0ba4\u0bc7\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd; (3)&nbsp;<strong>\u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/strong>&nbsp;\u2013 \u0b95\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0bb4\u0bb2\u0bbf\u0baf\u0bc8 \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf, \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b89\u0ba3\u0bb0\u0bb5\u0bc1\u0bae\u0bcd; (4)&nbsp;<strong>\u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>&nbsp;\u2013 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0b9f\u0bbf\u0baf\u0bc8 \u0b85\u0b95\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd, \u0b89\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb4\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd; (5)&nbsp;<strong>\u0ba4\u0b9f\u0bb5\u0bb2\u0bcd<\/strong>&nbsp;\u2013 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8\u0b95\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 MoS\u2082 \u0b95\u0bbf\u0bb0\u0bc0\u0bb8\u0bcd) \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc1\u0bb4\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0baa\u0bc2\u0b9a\u0bb5\u0bc1\u0bae\u0bcd; (6)&nbsp;<strong>\u0b87\u0bb3\u0b99\u0bcd\u0b95\u0bca\u0b9f\u0bbf \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong>&nbsp;\u2013 \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8 \u0b95\u0bc7\u0b9c\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd (\u0b9f\u0bc7\u0b9f\u0bcd\u0b9f\u0bbe\u0bb7\u0bc0\u0b9f\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u00b110% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd). \u0bae\u0b9a\u0b95\u0bc1\u0ba4\u0bb2\u0bcd, \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd\u0b95\u0bc8 110% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd\/\u0b9f\u0bc7\u0bb7\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd. &gt;125% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bb2 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcb, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vacuum circuit breaker (VCB) timing tests measure the mechanical response during opening and closing operations\u2014how fast contacts move, whether motion is smooth, and if performance matches manufacturer specifications. These tests verify that the breaker can interrupt fault current before damage occurs, that mechanical wear hasn\u2019t degraded performance, and that protection coordination assumptions remain valid. A [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2429,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-2425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2425"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2425\/revisions"}],"predecessor-version":[{"id":3569,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2425\/revisions\/3569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2429"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2425"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}