{"id":2511,"date":"2026-01-09T08:17:07","date_gmt":"2026-01-09T08:17:07","guid":{"rendered":"https:\/\/xbrele.com\/?p=2511"},"modified":"2026-04-07T14:53:36","modified_gmt":"2026-04-07T14:53:36","slug":"vacuum-contactor-maintenance-checklist","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/vacuum-contactor-maintenance-checklist\/","title":{"rendered":"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bcd\u0bb5\u0bc1"},"content":{"rendered":"<p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0-\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 10,000\u2013100,000 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b85\u0bb5\u0bcd\u0bb5\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bcb\u0bb2\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd, \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1, \u0b95\u0baa\u0bbe\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b86\u0ba9\u0bcd-\u0b86\u0b83\u0baa\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0ba8\u0bbe\u0bb3\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bb2\u0bae\u0bc1\u0bb1\u0bc8.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf, \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9 \u0bb5\u0b9f\u0bbf\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd, \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bb5\u0bc8\u2014\u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8. \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc8 \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bc7\u0baf\u0bc7 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b85\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b86\u0baf\u0bbf\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bc2\u0baa\u0bbe\u0baf\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0ba8\u0bc2\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bc2\u0baa\u0bbe\u0baf\u0bcd\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bbe\u0ba9 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf \u0ba8\u0bbe\u0b9f\u0b95\u0cc0\u0caf\u0bae\u0bbe\u0b95 \u0b85\u0bb1\u0bbf\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8. \u0b85\u0bb5\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0bb0\u0bae\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f 20% \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 5 ms \u0b85\u0bb3\u0bb5\u0bc1 \u0bb5\u0bbf\u0bb2\u0b95\u0bc1\u0bb5\u0ba4\u0bc1, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bc1 \u0ba4\u0bcb\u0ba9\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b86\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba4\u0bbf\u0bb1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0bb5\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf&nbsp;<a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor\/\">\u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd<\/a>&nbsp;\u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bb5\u0b99\u0bcd\u0b95\u0bbf\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bbf\u0bb2\u0bcd, \u0b87\u0ba8\u0bcd\u0ba4 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9\u0bb5\u0bc8.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1\" width=\"1290\" height=\"726\" src=\"https:\/\/www.youtube.com\/embed\/x-4uOSbSMeo?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/xbrele.com\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-maintenance-matters-more-for-contactors-than-breakers\">\u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b8f\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1<\/h2>\n\n\n\n<p>\u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0bb0\u0bbf\u0ba4\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b92\u0bb0\u0bc1\u0bb5\u0bc7\u0bb3\u0bc8 \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 5\u201320 \u0bae\u0bc1\u0bb1\u0bc8). \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0bb5\u0bb0\u0bc1\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b86\u0baf\u0bbf\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0b9f\u0bcd\u0b9f\u0ba3 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1<\/th><th>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd<\/th><th>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf<\/th><\/tr><\/thead><tbody><tr><td><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\/\u0b86\u0ba3\u0bcd\u0b9f\u0bc1<\/strong><\/td><td>5\u201320 (\u0b95\u0bc1\u0bb1\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd)<\/td><td>5,000\u201350,000 (\u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd)<\/td><\/tr><tr><td><strong>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf\u0ba4\u0bc1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/strong><\/td><td>10\u201340\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0baa\u0bb4\u0bc1\u0ba4\u0bc1)<\/td><td>1\u20138\u00d7 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0b89\u0bb3\u0bcd\u0bb3\u0bc7\u0bb1\u0bcd\u0bb1\/\u0b9a\u0bc1\u0bae\u0bc8)<\/td><\/tr><tr><td><strong>\u0b92\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd<\/strong><\/td><td>\u0bae\u0bbf\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bcd<\/td><td>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9<\/td><\/tr><tr><td><strong>\u0b95\u0bc1\u0bb5\u0bbf\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd<\/strong><\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 (\u0b9a\u0bbf\u0bb2 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/td><td>\u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bcd (\u0baa\u0bb2 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd)<\/td><\/tr><tr><td><strong>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf<\/strong><\/td><td>2,000\u20135,000 \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bb3\u0bcd<\/td><td>5,000\u201320,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b85\u0bb3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b87\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bbe\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-intervals-when-to-inspect\">\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd: \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart.webp\" alt=\"\u0b89\u0baf\u0bb0\u0bcd-\u0baa\u0ba3\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0baa\u0ba3\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0bbe\u0bb2 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\" class=\"wp-image-2515\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart-300x168.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart-768x429.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-03-maintenance-interval-flowchart-18x10.webp 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0baa\u0b9f\u0bae\u0bcd 3**: \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 5,000\/10,000\/20,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb2 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0bb2\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\/\u0b86\u0bb1\u0bc1\u0bae\u0bbe\u0ba4\u0bae\u0bcd\/\u0bb5\u0bb0\u0bc1\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b86\u0baf\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/figcaption><\/figure>\n\n\n\n<p>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0ba3\u0bbf, \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1. \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"time-based-intervals\">\u0b95\u0bbe\u0bb2 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b95\u0bbe\u0bb2\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1 (3 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/strong>: \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0b86\u0baf\u0bcd\u0bb5\u0bc1, \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd, \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li><strong>\u0b86\u0bb1\u0bc1 \u0bae\u0bbe\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 (6 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/strong>: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1, \u0ba8\u0bc7\u0bb0\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li><strong>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 (12 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/strong>: \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bcd\u0bb5\u0bc1, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li><strong>\u0b87\u0bb0\u0bc1 \u0bb5\u0bb0\u0bc1\u0b9f\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (24 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0bae\u0bcd, \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1, \u0ba4\u0bc1\u0ba3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0bcd\u0b9f \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"operation-based-intervals\">\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0b85\u0ba4\u0bbf\u0b95 \u0b9a\u0bc1\u0bae\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0ba8\u0bc7\u0bb0 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 5,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd<\/strong>: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/li>\n\n\n\n<li><strong>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 10,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd<\/strong>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 + \u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/li>\n\n\n\n<li><strong>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 20,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd<\/strong>: \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba8\u0bc7\u0bb0\u0bcd\u0bae\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/li>\n\n\n\n<li><strong>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 50,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd<\/strong>\u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd (\u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd)<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bb2\u0b95\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0bb8\u0bcd\u0b95\u0bbe\u0b9f\u0bbe\/\u0b9f\u0bbf\u0b9a\u0bbf\u0b8e\u0bb8\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbe\u0bb3\u0bcd\u0b95\u0bb3\u0bcd (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"condition-based-triggers\">\u0ba8\u0bbf\u0bb2\u0bc8 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p>\u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0b9a\u0bae\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b86\u0baf\u0bcd\u0bb5\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bbe\u0bb4\u0bcd\u0bb5\u0bc1 \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b95\u0bbf\u0ba3\u0bc1\u0b95\u0bbf\u0ba3\u0bc1\u0baa\u0bcd\u0baa\u0bc1)<\/li>\n\n\n\n<li>\u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b95\u0bb5\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bbe\u0bb1\u0bbe\u0ba9 \u0b9a\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1<\/li>\n\n\n\n<li>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b8f\u0bb1\u0bcd\u0bb1 \u0b87\u0bb1\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc2\u0b9f\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd\/\u0ba4\u0bb5\u0bb1\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"contact-resistance-measurement\">\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/h2>\n\n\n\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbe\u0b9a\u0bc1\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, I\u00b2R \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-it-matters\">\u0b85\u0ba4\u0bc1 \u0b8f\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bcd<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bae\u0ba3\u0bcd \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd<\/strong>: \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bb3\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u2192 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8<\/li>\n\n\n\n<li><strong>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bbe\u0ba4\u0bb2\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd<\/strong>\u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (P = I\u00b2R), \u0b87\u0ba4\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba4\u0bb2\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0bae\u0bc1\u0ba9\u0bcd\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/strong>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"equipment-required\">\u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd<\/strong>&nbsp;(100 A \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 200 A \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bb2 \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd (10 A) \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0b95\u0bc6\u0bb2\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd (4-\u0bb5\u0baf\u0bb0\u0bcd) \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0b95\u0bb2\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb0\u0bc7\u0bb7\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong>&nbsp;\u0b95\u0b9f\u0ba8\u0bcd\u0ba4 12 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd<\/li>\n\n\n\n<li><strong>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bca\u0bb3\u0bbf \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"procedure\">\u0bae\u0bc1\u0bb1\u0bc8<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0b9f\u0bc6\u0bb8\u0bcd\u0b9f\u0bb0\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bc1\/\u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bc6\u0bb1\u0bc1<\/li>\n\n\n\n<li>\u0b9f\u0bc7\u0b95\u0bcd \u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd (\u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc8 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bc6\u0bb2\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0bbf\u0bb3\u0bbf\u0baa\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0ba8\u0bb2\u0bcd\u0bb2 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd (\u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0b9f \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 5\u201310 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u03bc\u03a9 (\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0b93\u0bae\u0bcd\u0bb8\u0bcd) \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0b85\u0b9f\u0bbf\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd (\u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd) \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 (\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd)<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"acceptance-criteria\">\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<p><strong>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(12\u201338 kV \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9\u0ba4\u0bc1):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>: \u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 50\u2013150 \u03bc\u03a9<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1<\/strong>: 300 \u03bc\u03a9 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4reshold<\/strong>: &gt;250 \u03bc\u03a9 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0b9a\u0bb2\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd 3 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 50%-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u2192 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba9\u0bc8-\u0bae\u0bc1\u0ba9\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 &gt;30% \u2192 \u0b9a\u0bae\u0bae\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0b95\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (&gt; \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 20%) \u2192 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0b95\u0bae\u0bcd\u0baa\u0bae\u0bcd<\/th><th>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 (\u0baa\u0bc1\u0ba4\u0bbf\u0baf\u0ba4\u0bc1)<\/th><th>\u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/th><th>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/th><\/tr><\/thead><tbody><tr><td>A<\/td><td>80 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb \u0b93\u0bae\u0bcd<\/td><td>120 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb \u0b93\u0bae\u0bcd<\/td><td>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1 (+50%, \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd)<\/td><\/tr><tr><td>B<\/td><td>85 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb \u0b93\u0bae\u0bcd<\/td><td>135 \u03bc\u03a9<\/td><td>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1 (+59%, \u0b89\u0ba9\u0bcd\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd)<\/td><\/tr><tr><td>C<\/td><td>82 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb \u0b93\u0bae\u0bcd<\/td><td>210 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0b93\u0bae\u0bcd<\/td><td><strong>\u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8<\/strong>&nbsp;(+156%, \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8 \u0ba8\u0bc6\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u0b95\u0bae\u0bcd\u0baa\u0bae\u0bcd C \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bbe\u0bb3\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0ba9\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement.webp\" alt=\"4-\u0bb5\u0baf\u0bb0\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bc1 \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bc6\u0bb2\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0bbf\u0bb3\u0bbf\u0baa\u0bcd \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\" class=\"wp-image-2513\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-01-contact-resistance-measurement-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0baa\u0b9f\u0bae\u0bcd 1**: \u0b95\u0bc6\u0bb2\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd (4-\u0bb5\u0baf\u0bb0\u0bcd) \u0b95\u0bbf\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf 100A+ \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u2014\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0baa\u0b9f\u0bbf\u0b95\u0bb3\u0bc8 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bbf \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b89\u0bb2\u0bcb\u0b95-\u0bae\u0bc1\u0ba4\u0bb2\u0bcd-\u0b89\u0bb2\u0bcb\u0b95\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bb3\u0b95\u0bcd\u0b95, \u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd &lt;250 \u03bc\u03a9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vacuum-integrity-check\">\u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 10\u207b\u2074 \u0baa\u0bbe (10\u207b\u2076 \u0b9f\u0bbe\u0bb0\u0bcd) \u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0baa\u0bb2 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1, \u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0ba8\u0bc1\u0bb4\u0bc8\u0baf \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"why-vacuum-degrades\">\u0b8f\u0ba9\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b9a\u0bc0\u0bb0\u0bcd\u0b95\u0bc1\u0bb2\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd<\/strong>: \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd-\u0b89\u0bb2\u0bcb\u0b95 \u0bae\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bb9\u0bc0\u0bb2\u0bbf\u0baf\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0b85\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bb0\u0bb5\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/li>\n\n\n\n<li><strong>\u0ba8\u0bc1\u0ba3\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf, \u0baa\u0bb1\u0bcd\u0bb1\u0ba3 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bc1\u0ba3\u0bcd\u0ba3\u0bbf\u0baf \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li><strong>\u0b89\u0bb3\u0bcd\u0bb3\u0b95 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/strong>: \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0bb2\u0bcb\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0b95\u0bc8\u0baf\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf<\/strong>: \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bc0\u0bb2\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b9a\u0bc7\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9\u0ba4\u0bc1 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0ba4\u0bc1\u2014\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0b86\u0ba9\u0bbe\u0bb2\u0bcd, \u0baa\u0bbf\u0bb4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"test-methods\">\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-1-high-voltage-proof-test-most-reliable\">\u0bae\u0bc1\u0bb1\u0bc8 1: \u0b89\u0baf\u0bb0\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (\u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9\u0ba4\u0bc1)<\/h4>\n\n\n\n<p>\u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc7 \u0b8f\u0b9a\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1 \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b8f\u0b9a\u0bbf \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf (\u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf 10\u201350 kV)<\/li>\n\n\n\n<li>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8<\/li>\n\n\n\n<li>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b95\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd (\u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f BIL-\u0b87\u0ba9\u0bcd 70\u201380%).<\/li>\n\n\n\n<li>1 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0bae\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 = \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0baf\u0bbe\u0ba4\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1, \u0b87\u0b9f\u0bc8\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8 (\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0bb5\u0baf\u0b95\u0bcd\u0baf\u0bc2\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f \u0bb5\u0bbe\u0baf\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-2-contact-gap-withstand-voltage-test\">\u0bae\u0bc1\u0bb1\u0bc8 2: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/h4>\n\n\n\n<p>\u0bae\u0bc1\u0bb1\u0bc8 1-\u0b90\u0baa\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0b9f\u0bc6\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0b9f\u0bc6\u0bb8\u0bcd\u0b9f\u0bb0\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 1,000 V DC-\u0b90\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0ba8\u0bb2\u0bcd\u0bb2 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd: &gt;100 M\u03a9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8, \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/li>\n\n\n\n<li>\u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bbf: \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcb\u0bb5\u0bb0\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f \u0bb5\u0bbe\u0baf\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9, \u0b8e\u0bb3\u0bbf\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb1\u0bbf\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-3-contact-travel-measurement-indirect-indicator\">\u0bae\u0bc1\u0bb1\u0bc8 3: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 (\u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0b9f\u0bc8\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf)<\/h4>\n\n\n\n<p>\u0b87\u0ba4\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3 \u0ba4\u0bc2\u0bb0\u0bae\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf\u0ba4\u0bc1 (\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0bb3\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bae\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bb1\u0bcd\u0bb1\u0bc7 \u0b92\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9).<\/p>\n\n\n\n<p><strong>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0bae\u0bcd:<\/strong>&nbsp;MV \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 8\u201312 \u0bae\u0bbf\u0bae\u0bc0.<br><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8:<\/strong>&nbsp;\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 80% \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"method-4-infrared-thermography-during-operation-advanced\">\u0bae\u0bc1\u0bb1\u0bc8 4: \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0b95\u0b9a\u0bcd\u0b9a\u0bbf\u0bb5\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0b9f\u0bae\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 (\u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f)<\/h4>\n\n\n\n<p>\u0ba4\u0bb5\u0bb1\u0bbf\u0baf \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bca\u0bb3\u0bbf \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bc1<\/li>\n\n\n\n<li>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bca\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b95\u0bbe\u0bb2\u0bbf\u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0b95\u0bc1\u0ba4\u0bbf &gt; \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f 30\u00b0C \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0b9a\u0bae\u0bae\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba8\u0bb0\u0bcd \u0b89\u0b9f\u0bb2\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b89\u0bb3\u0bcd\u0bb3\u0bc2\u0bb0\u0bcd\u0bae\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba8\u0ba9\u0bcd\u0bae\u0bc8:<\/strong>&nbsp;\u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bbe\u0ba4\u0ba4\u0bc1, \u0b85\u0bb1\u0bc1\u0bb5\u0bc8 \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb2\u0bbe\u0bae\u0bcd.<br><strong>\u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1:<\/strong>&nbsp;\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0bbf\u0bb1\u0bcd\u0b9a\u0bbf \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0b9f\u0bae\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"recommended-practice\">\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0<\/strong>: \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8 2-\u0b90 (\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8) \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 2\u20133 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd<\/strong>: \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0bae\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0bae\u0bc1\u0bb1\u0bc8 1 (\u0b89\u0baf\u0bb0\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8) \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0b95<\/strong>&nbsp;(\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0bbe\u0bb2\u0bcd): \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8 4 (\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0b9f\u0bae\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1) \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-to-do-if-vacuum-is-lost\">\u0bb5\u0baf\u0b95\u0bcd\u0baf\u0bc2\u0bae\u0bcd \u0b87\u0bb4\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1<\/h3>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0b95\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bcb \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1. \u0b92\u0bb0\u0bc7 \u0bb5\u0bb4\u0bbf:&nbsp;<strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1<\/strong>.<\/p>\n\n\n\n<p><strong>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0bae\u0bb0\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u2192 \u0b87\u0b9f\u0bc8\u0baf\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc8 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd (\u0b9a\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0b85\u0bb0\u0bc8\u0baf\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u2192 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0ba8\u0bb2\u0bcd\u0bb2 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u2192 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1, \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ol>\n\n\n\n<p>\u0b87\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd\u00a0<a href=\"https:\/\/xbrele.com\/ta\/switchgear-component-manufacturer\/\" data-type=\"page\" data-id=\"1967\">\u0ba4\u0b95\u0bc1\u0ba4\u0bbf\u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/a>\u00a0\u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb0\u0ba3\u0bcd\u0b9f\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 $200\u2013$800 \u0bb5\u0bb0\u0bc8 \u0b9a\u0bc6\u0bb2\u0bb5\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1\u2014\u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bbe\u0ba9 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bc7\u0baf\u0bc7 \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb0\u0baa\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mechanical-inspection\">\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1<\/h2>\n\n\n\n<p>\u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd, \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbe\u0bb4\u0bcd\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba9. \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"inspection-points\">\u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"1.-operating-mechanism-condition\">1. \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8<\/h4>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0baa\u0bc2\u0b9a\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0b95\u0bbf\u0bb0\u0bc0\u0bb8\u0bcd \u0b95\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc2\u0b9a\u0bbf\u0baf\u0bbe\u0bb2\u0bcd \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0b9a\u0b95\u0bc1 \u0b85\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bc8 \u0b88\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4 \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd (\u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bbe\u0b95\u0bbf, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb0\u0bb5\u0bae\u0bbe\u0b95\u0bc1\u0ba4\u0bb2\u0bcd)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0baa\u0bc2\u0b9a\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 -40\u00b0C \u0bae\u0bc1\u0ba4\u0bb2\u0bcd +125\u00b0C \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0bb2\u0bbf\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0bbf\u0bb0\u0bc0\u0bb8\u0bcd).<\/li>\n\n\n\n<li>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bbf\u0b9f\u0bcd \u0baa\u0bbe\u0baf\u0bbf\u0ba3\u0bcd\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0bc0\u0bb3\u0bcd\u0bb5\u0b9f\u0bcd\u0b9f \u0bb5\u0b9f\u0bbf\u0bb5 \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b85\u0b9a\u0bc8\u0bb5\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0ba8\u0bc0\u0bb0\u0bc2\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bbf\u0bb0\u0ba8\u0bcd\u0ba4\u0bb0\u0bae\u0bbe\u0ba9 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b89\u0ba4\u0bbf\u0bb0\u0bbf \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bcd \u0b95\u0bc8\u0baf\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong>:\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0bbe\u0b95 \u0ba8\u0b95\u0bb0\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0ba4\u0bc2\u0ba3\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bae \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf<\/li>\n\n\n\n<li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb2\u0b95\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bae\u0bcd \u0b9a\u0bc0\u0bb0\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0b9a\u0ba4\u0bbf\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bbe\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bb5\u0bb3\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcb \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcb, \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"2.-contact-travel-and-timing\">2. \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/h4>\n\n\n\n<p><strong>\u0baa\u0baf\u0ba3 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1:<\/strong><\/p>\n\n\n\n<p><strong>\u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/strong>&nbsp;\u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0baf\u0ba3 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b9f\u0bc6\u0bb8\u0bcd\u0b9f\u0bcd \u0b9c\u0bbe\u0b95\u0bcd\u0b95\u0bbf \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bbf \u0bb2\u0bc0\u0bb5\u0bb0\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd)<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bb0\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3 \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bb2\u0b95\u0bc8 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd:<\/strong>&nbsp;12 kV \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 8\u201312 \u0bae\u0bbf\u0bae\u0bc0, 24 kV \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 10\u201315 \u0bae\u0bbf\u0bae\u0bc0<\/p>\n\n\n\n<p><strong>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 90\u2013110% = \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1<\/li>\n\n\n\n<li>&lt;90% = \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd (\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0bb5\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd)<\/li>\n\n\n\n<li>110% = \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba3 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8:<\/strong><\/p>\n\n\n\n<p><strong>\u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/strong>&nbsp;\u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b85\u0ba4\u0bbf\u0bb5\u0bc7\u0b95 \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b9f\u0bc8\u0bae\u0bbf\u0b99\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0b86\u0ba9 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0b86\u0ba9\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd:<\/strong>&nbsp;50\u2013100 \u0bae\u0bbf.\u0bb5\u0bbf<br><strong>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd:<\/strong>&nbsp;20\u201350 \u0bae\u0bbf.\u0bb5\u0bbf<\/p>\n\n\n\n<p><strong>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u00b110%-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd = \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0bb2\u0baa\u0bcd\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 (\u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b89\u0baf\u0bb0\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1) = \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd, \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd (&gt;20%) = \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0baa\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement.webp\" alt=\"\u0b9f\u0baf\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bbf\u0b95\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bb0\u0bc8 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd 10.5 \u0bae\u0bbf\u0bae\u0bc0 \u0baa\u0baf\u0ba3 \u0ba4\u0bc2\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\" class=\"wp-image-2514\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-02-contact-travel-measurement-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0baa\u0b9f\u0bae\u0bcd 2**: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b86\u0bb0\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b9f\u0baf\u0bb2\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf \u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b87\u0b9f\u0baa\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0bb5\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 (12 kV \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 8-12 \u0bae\u0bbf\u0bae\u0bc0), \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f &lt;80%, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0b9a\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b92\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"3.-auxiliary-contacts-and-interlocks\">3. \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/h4>\n\n\n\n<p><strong>\u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/strong>: NO \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd NC \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bbf\u0ba9\u0bcd\u0bb1\u0bbf, \u0b9a\u0ba4\u0bcd\u0ba4\u0bae\u0bbf\u0ba9\u0bcd\u0bb1\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/li>\n\n\n\n<li><strong>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1<\/strong>\u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/li>\n\n\n\n<li><strong>\u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0ba4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b89\u0ba4\u0bb5\u0bbf\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb2\u0bcd\u0b9f\u0bbe\u0b95\u0bbf \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9 (\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba9)<\/li>\n\n\n\n<li>\u0b89\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bcd\u0bb5\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bbe\u0b95\u0bb5\u0bcb \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0bb0\u0bb1\u0bcd\u0bb1 \u0ba8\u0bbf\u0bb2\u0bc8<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bc8 \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b95\u0bc8\u0baf\u0bbe\u0bb2\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0bb5\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9, \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0bae\u0bc6\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bb1\u0bcd\u0bb1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1)<\/li>\n\n\n\n<li>\u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bc8 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bc6\u0ba9\u0bcd\u0bb1\u0bc7 \u0bae\u0bc0\u0bb1 \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd)<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"4.-arc-chutes-and-barriers\">4. \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b87\u0bb1\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd<\/h4>\n\n\n\n<p>\u0b9a\u0bbf\u0bb2 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf \u0bb5\u0bb3\u0bc8\u0b95\u0bbe\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.<\/p>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0b9f\u0bcd\u0b9f\u0bbf\u0b99\u0bcd \u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0b9a\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0bb0\u0bcd\u0baa\u0ba9\u0bcd \u0ba4\u0b9f\u0bae\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd (\u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b95\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bb3\u0bcd)<\/li>\n\n\n\n<li>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0bb5\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b90\u0b9a\u0bcb\u0baa\u0bbf\u0bb0\u0bc8\u0bb2\u0bcd \u0b86\u0bb2\u0bcd\u0b95\u0bb9\u0bbe\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0baa\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li>\u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0b9f\u0bc8\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb0\u0bbe\u0baf\u0bb5\u0bc1\u0bae\u0bcd (\u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bae\u0bc8, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0bae\u0bcd)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"coil-and-control-circuit-checks\">\u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0ba8\u0ba9\u0bcd\u0b95\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0b9f\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"coil-resistance-measurement\">\u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/h3>\n\n\n\n<p><strong>\u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong>&nbsp;\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd, \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd DC \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0b85\u0b9f\u0bbf\u0ba8\u0bbf\u0bb2\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u00b110%-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd = \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0ba4\u0bc1<\/li>\n\n\n\n<li>\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 (&lt;20% \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7) = \u0bb7\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd \u0b86\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd \u2192 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b85\u0bb3\u0bb5\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 (&gt;20% \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bbf\u0b9f) = \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"coil-insulation-resistance\">\u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8<\/h3>\n\n\n\n<p><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bae\u0bcd\u0baa\u0bbf \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd\u0b9a\u0b9f\u0bcd\u0b9f\u0bae\u0bcd\/\u0ba8\u0bbf\u0bb2\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>500 V DC \u0bae\u0bc6\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1: &gt;10 M\u03a9<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong>&nbsp;(&lt;1 M\u03a9) \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b89\u0bb2\u0bb0 \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"control-voltage-verification\">\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n\n\n\n<p>\u0b8f\u0b9a\u0bbf \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9f\u0bbf\u0b9a\u0bbf \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 (110 V, 125 V, 220 V, \u0baa\u0bcb\u0ba9\u0bcd\u0bb1\u0bb5\u0bc8) \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b8e\u0bb3\u0bbf\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8.<\/p>\n\n\n\n<p><strong>\u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 85\u2013110% \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (&lt;85%):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bbe\u0ba9 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bae\u0bc1\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd\u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd (\u0b87\u0b9f\u0bc8\u0bb5\u0bbf\u0b9f\u0bbe\u0ba4\u0bc1 \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd)<\/li>\n\n\n\n<li>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0bb5\u0bb4\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0bb5\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (&gt;110%):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bae\u0bc0\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0ba4\u0bbe\u0b95\u0bcd\u0b95 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/li>\n\n\n\n<li>\u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bcd<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong>&nbsp;\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bcd\u2014\u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b93\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"documentation-and-trending\">\u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0bae\u0bc2\u0bb2 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0baf\u0ba9\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8. \u0b95\u0bbe\u0bb2\u0baa\u0bcd\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1, \u0b9a\u0bc0\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-to-record\">\u0b8e\u0ba9\u0bcd\u0ba9 \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1<\/h3>\n\n\n\n<p>\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bc7\u0ba4\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd<\/strong>&nbsp;\u0b86\u0baf\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/strong>&nbsp;(\u0b95\u0bbf\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd)<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8<\/strong>&nbsp;\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd (\u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0b93\u0bae\u0bcd-\u0b95\u0bb3\u0bbf\u0bb2\u0bcd)<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8<\/strong>&nbsp;\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1<\/li>\n\n\n\n<li><strong>\u0ba8\u0bc7\u0bb0 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(\u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd, \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd)<\/li>\n\n\n\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3\u0bae\u0bcd<\/strong>&nbsp;\u0b85\u0bb3\u0bb5\u0bc1 (\u0bae\u0bbf\u0bae\u0bc0-\u0bb2\u0bcd)<\/li>\n\n\n\n<li><strong>\u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/strong>&nbsp;(\u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1, \u0b9a\u0bc7\u0ba4\u0bae\u0bcd)<\/li>\n\n\n\n<li><strong>\u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0bb3\u0bcd<\/strong>&nbsp;\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1 (\u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd, \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd, \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9)<\/li>\n\n\n\n<li><strong>\u0b86\u0baf\u0bcd\u0bb5\u0bbe\u0bb3\u0bb0\u0bcd \u0baa\u0bc6\u0baf\u0bb0\u0bcd\/\u0b95\u0bc8\u0baf\u0bca\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/strong><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"trending-analysis\">\u0baa\u0bbf\u0bb0\u0baa\u0bb2\u0bae\u0bbe\u0ba9 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/h3>\n\n\n\n<p>\u0b95\u0bbe\u0bb2\u0baa\u0bcd\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>: \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0b95, \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bbe\u0b95 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb2\u0bc7\u0b9a\u0bbe\u0b95 \u0bb5\u0bb3\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>\u0baa\u0b9a\u0bc8 \u0baa\u0bb4\u0bc8\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bb1\u0bcd\u0bb1\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0bb5\u0bbf\u0b9a\u0bbf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0b95\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd (\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bc1, \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1) \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong><\/p>\n\n\n\n<p>20,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 100 \u03bc\u03a9-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 150 \u03bc\u03a9 \u0b86\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0baa\u0bc1\u0bb1\u0b9a\u0bcd\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd\u0baa\u0b9f\u0bbf ~50,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 250 \u03bc\u03a9 \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u2014\u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"creating-a-maintenance-schedule-template\">\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8 \u0bb5\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0bb0\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd<\/h3>\n\n\n\n<p><strong>\u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bcd:<\/strong><\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1   \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0bae\u0bcd: VC-101   \u0b87\u0b9f\u0bae\u0bcd: MCC-3, \u0baa\u0bc7 5   \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd: XBRELE   \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd: 12 kV   \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd: 400 A   \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1: \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0bb8\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd (\u0bb5\u0bbf\u0b9a\u0bbf\u0bb1\u0bbf \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd)\n\n\u0ba4\u0bc7\u0ba4\u0bbf: _______ \u0b95\u0b9f\u0ba8\u0bcd\u0ba4 \u0b86\u0baf\u0bcd\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd: _______ \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8: _______\u00b0C \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 (\u03bc\u03a9): \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd A: _______ (\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8: 85 \u03bc\u03a9) \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd B: _______ (\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8: 82 \u03bc\u03a9) \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd C: _______ (\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8: 88 \u03bc\u03a9)\n\n\u0ba8\u0bc7\u0bb0\u0bae\u0bcd: \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd: _______ ms (\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1: 60-80 ms) \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd: _______ ms (\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1: 25-35 ms) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba3 \u0ba4\u0bc2\u0bb0\u0bae\u0bcd: _______ mm (\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1: 10 \u00b1 1 mm) \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0b86\u0baf\u0bcd\u0bb5\u0bc1: [ ] \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0bae\u0b9a\u0b95\u0bc1 \u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1\n  [ ] \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 [ ] \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 [ ] \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 [ ] \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b85\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0b9a\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0bb3\u0bcd: _____________________________________________ \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc7\u0ba4\u0bbf: _________ (\u0ba4\u0bc7\u0ba4\u0bbf) \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 _________ \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bbe\u0bb3\u0bb0\u0bcd: __________________ \u0b95\u0bc8\u0baf\u0bca\u0baa\u0bcd\u0baa\u0bae\u0bcd: __________\n<\/code><\/pre>\n\n\n\n<p>\u0b89\u0baa\u0b95\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0baa\u0bb2 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b92\u0bb0\u0bc7 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-problems-and-troubleshooting\">\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf<\/th><th>\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd<\/th><th>\u0ba8\u0bcb\u0baf\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/th><th>\u0bae\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1<\/th><\/tr><\/thead><tbody><tr><td><strong>\u0bae\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1<\/strong><\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0baa\u0bcd \u0baa\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/td><td>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd, \u0b92\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bbe \u0b8e\u0ba9\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/td><td>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bae\u0bcd, \u0ba4\u0b9f\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0baf\u0bbf\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/td><\/tr><tr><td><strong>\u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8<\/strong><\/td><td>\u0ba4\u0bc1\u0bb5\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8, \u0b92\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/td><td>\u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbe\u0bb2\u0bcd), \u0ba4\u0bbf\u0bb1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bc8 \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/td><td>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bc1\u0b9f\u0bc1\u0bb5\u0bc8, \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd; \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/td><\/tr><tr><td><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0b9f\u0bcd\u0b9f\u0bc8<\/strong><\/td><td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0bae\u0bbe\u0b9a\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1<\/td><td>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/td><td>\u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0bae\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/td><\/tr><tr><td><strong>\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd<\/strong><\/td><td>\u0b85\u0ba4\u0bbf\u0b95 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bae\u0bc8, \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd<\/td><td>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bb3\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd, \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/td><td>\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd\/\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd, \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b87\u0b9f\u0bc8\u0baf\u0bc2\u0bb1\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0baf\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/td><\/tr><tr><td><strong>\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bbe\u0bb2\u0bbe\u0bb5\u0ba4\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1<\/strong><\/td><td>\u0b85\u0ba3\u0bbf\u0baf\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0bae\u0b9a\u0b95\u0bc1, \u0ba4\u0bc1\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b9a\u0bcb\u0bb0\u0bcd\u0bb5\u0bc1<\/td><td>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd, \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/td><td>\u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0b87\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd, \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"765\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree.webp\" alt=\"\u0bb5\u0baf\u0b95\u0bcd\u0baf\u0bc2\u0bae\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9 \u0bae\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd, \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 (\u0bae\u0bc2\u0b9f \u0bae\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd, \u0b9a\u0ba4\u0bcd\u0ba4\u0bae\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bbe\u0ba4\u0bb2\u0bcd) \u0bae\u0bc2\u0bb2 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.\" class=\"wp-image-2516\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree-300x224.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree-768x574.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/01\/fig-04-troubleshooting-decision-tree-16x12.webp 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">**\u0baa\u0b9f\u0bae\u0bcd 4**: \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1 \u0bae\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\/\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd\/\u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf, \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"safety-precautions\">\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc6\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba9.<\/p>\n\n\n\n<p><strong>\u0bb5\u0bc7\u0bb2\u0bc8 \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0ba4\u0ba9\u0bbf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong>\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n\n\n\n<li><strong>\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd<\/strong>\u0b95\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb1\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b95\u0bcd\u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc2\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bae\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\/\u0b95\u0bc1\u0bb1\u0bbf\u0bae\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1<\/strong>\u0bb5\u0bc7\u0bb2\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcd \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0b85\u0bb1\u0bcd\u0bb1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc7\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0b9a\u0bbf\u0bb1\u0bbf\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>: \u0baa\u0baf\u0bbf\u0bb1\u0bcd\u0b9a\u0bbf \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n\n\n\n<li><strong>\u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/strong>: \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bc7\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0b85\u0ba4\u0bc1 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9, \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bc1<\/strong>: \u0baa\u0bb4\u0bc8\u0baf \u0b95\u0bbf\u0bb0\u0bc0\u0bb8\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc2\u0b9a\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd (\u0b95\u0bc7\u0b9f\u0bcd\u0bae\u0bbf\u0baf\u0bae\u0bcd, \u0bb5\u0bc6\u0bb3\u0bcd\u0bb3\u0bbf) \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd\u2014\u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b95\u0bc8\u0baf\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/strong>\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>\u0b9a\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0baa\u0bb2\u0bae\u0bc1\u0bb1\u0bc8 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n\n\n\n<li><strong>\u0b9a\u0bc1\u0bae\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong>&nbsp;\u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0bbe\u0bb2\u0bcd: \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n\n\n\n<p>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 VCB \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u00a0<a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\" data-type=\"page\" data-id=\"1071\">\u0b8e\u0b95\u0bcd\u0bb8\u0bcd.\u0baa\u0bbf.\u0b86\u0bb0\u0bcd.\u0b87.\u0b8e\u0bb2\u0bcd.\u0b87-\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd<\/a> \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"key-takeaways\">\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 (\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 5\u201320 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 5,000\u201350,000 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd), \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 (100A+ \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd\u2014&gt;250 \u03bc\u03a9 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 3\u00d7 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 (\u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0bb1\u0bc1 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8) \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n\n\n\n<li>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0baf\u0ba3 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1 (\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb3\u0bb5\u0bbf\u0bb2\u0bcd 90\u2013110% \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd), \u0b95\u0bbe\u0bb2 \u0b85\u0bb3\u0bb5\u0bc1 (\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u00b110%), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1\u2014\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9 \u0bb5\u0b9f\u0bbf\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0b9a\u0bcd\u0b9a\u0bc1\u0bae\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0ba8\u0bc7\u0bb0 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd (\u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 5,000\/10,000\/20,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd) \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n\n\n\n<li>\u0b89\u0baa\u0b95\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0ba4\u0bb0\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b92\u0bb0\u0bc7 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bbe\u0ba4 \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n\n\n\n<li>\u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0b95\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1\u2014\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc7 \u0b92\u0bb0\u0bc7 \u0bb5\u0bb4\u0bbf.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1:<\/strong>&nbsp;<a href=\"https:\/\/webstore.iec.ch\/publication\/6709\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 62271-106<\/a>&nbsp;\u2014 \u0b8f\u0b9a\u0bbf \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 IEC 62271-106 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<p><strong>\u0b95\u0bc71: \u0b92\u0bb0\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b85\u0bb3\u0bb5\u0bbf\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/strong><br>\u0b85: \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (\u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd), \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 5,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0bb1\u0bc1 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8, \u0b8e\u0ba4\u0bc1 \u0bae\u0bc1\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0bb5\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bcb \u0b85\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 (&lt;1,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd\/\u0b86\u0ba3\u0bcd\u0b9f\u0bc1), \u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bc1. \u0baa\u0bc1\u0ba4\u0bbf\u0baf\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc7 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bbf, \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc72: \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/strong><br>A: \u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd \u0b92\u0bb0\u0bc7 \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bbe\u0ba9\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u2014\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b8e\u0ba9\u0bb5\u0bc7 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 10,000 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8 \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd; \u0b92\u0bb0\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd 30,000\u201350,000 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc73: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f \u0ba8\u0bbe\u0ba9\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bae\u0bb2\u0bcd\u0b9f\u0bbf\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbe\u0bae\u0bbe?<\/strong><br>A: \u0b87\u0bb2\u0bcd\u0bb2\u0bc8\u2014\u0bae\u0bb2\u0bcd\u0b9f\u0bbf\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0b86\u0bae\u0bcd\u0baa\u0bcd-\u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b85\u0bb5\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0bae\u0bb2\u0bcd, \u0ba4\u0bb5\u0bb1\u0bbe\u0b95 \u0b85\u0ba4\u0bbf\u0b95 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bbf, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b89\u0bb2\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0bb2\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f, 100A-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb-\u0b93\u0bae\u0bcd\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc74: \u0b8e\u0ba9\u0bcd\u0ba9\u0bbf\u0b9f\u0bae\u0bcd \u0b89\u0baf\u0bb0\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8\u0baf\u0bc6\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf \u0b85\u0bb1\u0bbf\u0bb5\u0ba4\u0bc1?<\/strong><br>A: \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 1,000V DC \u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0ba8\u0bb2\u0bcd\u0bb2 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd &gt;100 M\u03a9 \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd, \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bcd (\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0b9f\u0bae\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1), \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0bae\u0bcd (\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bbf\u0bb2\u0bcd &lt;80%), \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b87\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0b8f\u0ba4\u0bc7\u0ba9\u0bc1\u0bae\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc75: \u0b95\u0bbe\u0bb2\u0baa\u0bcd\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b87\u0bb4\u0b95\u0bcd\u0b95 \u0b8e\u0ba9\u0bcd\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd?<\/strong><br>A: \u0b9a\u0bc6\u0bb0\u0bbe\u0bae\u0bbf\u0b95\u0bcd-\u0b89\u0bb2\u0bcb\u0b95 \u0bae\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bbe\u0baf\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd (\u0bb9\u0bc0\u0bb2\u0bbf\u0baf\u0bae\u0bcd, \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd), \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc1\u0ba3\u0bcd-\u0baa\u0bbf\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0baf\u0bcd\u0bae\u0bbe\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 15\u201325 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd, \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n\n\n\n<p><strong>\u0b95\u0bc76: \u0ba8\u0bbe\u0ba9\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0b9a\u0b95\u0bc1 \u0b87\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bbe?<\/strong><br>A: \u0b92\u0bb0\u0bc1\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8\u2014\u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0b9a\u0b95\u0bc1 \u0baa\u0bcb\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1. \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b89\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bc7\u0bb0\u0bbf\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bcd, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb4\u0bb2\u0bcd \u0bae\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0bae\u0b9a\u0b95\u0bc1 \u0baa\u0bcb\u0b9f\u0bb5\u0bc1\u0bae\u0bcd. \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0ba4\u0bcd\u0ba4 \u0bae\u0b9a\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 -40 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd +125\u00b0C \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0baa\u0bc6\u0bb1\u0bcd\u0bb1 \u0bb2\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bae\u0bcd \u0b95\u0bbf\u0bb0\u0bc0\u0bb8\u0bcd).<\/p>\n\n\n\n<p><strong>\u0b95\u0bc77: \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd?<\/strong><br>A: \u0ba4\u0b9f \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1: 20,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 100 \u03bc\u03a9-\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 180 \u03bc\u03a9-\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bc7\u0bb0\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, ~50,000 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 250 \u03bc\u03a9 \u0b9a\u0bc7\u0bb5\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8 \u0b8e\u0b9f\u0bcd\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd\u2014\u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd. \u0ba4\u0bbf\u0b9f\u0bc0\u0bb0\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd (&gt;20% \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd) \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"related-reading-and-selection-resources\">\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0bb5\u0bbe\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor\/ckg-vacuum-contactor\/\">CKG \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf<\/a> ? \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Medium-voltage vacuum contactors operate 10,000\u2013100,000 mechanical cycles over their service life. Unlike circuit breakers that interrupt fault currents occasionally, contactors switch load currents repeatedly\u2014often multiple times daily in motor control, capacitor switching, and frequent start-stop applications. This repetitive duty creates wear patterns maintenance teams must detect before they cause failures. Contact erosion from repeated arcing, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2512,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-2511","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vaccum-contactor-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2511","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=2511"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2511\/revisions"}],"predecessor-version":[{"id":3619,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/2511\/revisions\/3619"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/2512"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=2511"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=2511"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=2511"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}