{"id":3679,"date":"2026-04-28T00:00:00","date_gmt":"2026-04-28T00:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3679"},"modified":"2026-06-18T08:22:07","modified_gmt":"2026-06-18T08:22:07","slug":"control-cable-selection-mv-panels","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/control-cable-selection-mv-panels\/","title":{"rendered":"MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1: \u0b95\u0bb5\u0b9a\u0bae\u0bcd, \u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f\u0bae\u0bcd"},"content":{"rendered":"<h2>\u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0bae\u0bcd: \u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0baa\u0bcd \u0baa\u0b99\u0bcd\u0b95\u0bc1<\/h2>\n<p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (MV) \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bb0\u0bae\u0bcd\u0baa\u0bc1 \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0bae\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0b99\u0bcd, \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b92\u0bb0\u0bc1 \u0b92\u0bb1\u0bcd\u0bb1\u0bc8 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bbf, \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<p>\u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bc8 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0ba4\u0bbf\u0ba9\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bb2\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4 \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bb1\u0bcd\u0bb1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bb2 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bc7\u0ba9\u0bcd. \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba4\u0bc1\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0d2e\u0d3e\u0d15\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1, \u0ba4\u0bc0\u0baf\u0bbe\u0bb2\u0bcd \u0b9a\u0bc7\u0ba4\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb1\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc0\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bcd\u0bb5\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd\u2014\u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0bae\u0bc2\u0bb2 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1: \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4\u0ba4\u0bc1.<\/p>\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf, 1kV \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 52kV \u0bb5\u0bb0\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b85\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb5\u0b9a\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd, \u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f\u0b95\u0bbe\u0bb2 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1.<\/p>\n<h2>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0b85\u0ba3\u0bbf\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb5\u0b95\u0bc8<\/th>\n<th>\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/th>\n<th>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b8e\u0bb8\u0bcd\u0b9a\u0bbf\u0b93\/\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bc1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CT \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/td>\n<td>\u0baa\u0bbf\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0bae\u0bcd\u0baa\u0bc1, \u0b92\u0b9f\u0bcd\u0b9f\u0bc1\u0ba8\u0bbe\u0bb0\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bcd, \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0b95 \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb3\u0bcd\u0bb3\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/td>\n<td>\u0b9a\u0bc1\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bc1\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0baf\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/td>\n<\/tr>\n<tr>\n<td>\u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd, \u0bae\u0bc2\u0b9f\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd-\u0b9a\u0bbe\u0bb0\u0bcd\u0b9c\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/td>\n<td>\u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b83\u0baa\u0bc6\u0bb0\u0bc2\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf 2.5 \u0bae\u0bbf\u0bae\u0bc0\u00b2 \u0baa\u0b9f\u0bcd\u0b9f\u0bc8 \u0b95\u0bae\u0bcd\u0baa\u0bbf<\/td>\n<td>\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb4\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc1.<\/td>\n<\/tr>\n<tr>\n<td>\u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/td>\n<td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9c\u0bcb\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/td>\n<td>\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0b9a\u0bbf\u0baf\u0bc6\u0ba9\u0bcd\u0b9f\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbf\u0bb0\u0bb5\u0bc1\u0ba3\u0bcd\u0b9f\u0bcd \u0bb7\u0bc0\u0bb2\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bc6\u0ba9\u0bcd\u0bb1\u0bc7 \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/td>\n<\/tr>\n<tr>\n<td>\u0b88\u0ba4\u0bb0\u0bcd\u0ba8\u0bc6\u0b9f\u0bcd, \u0b86\u0bb0\u0bcd\u0b8e\u0bb8\u0bcd-485, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b90\u0b87\u0b9a\u0bbf 61850 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/td>\n<td>EMC \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f-\u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8 \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd<\/td>\n<td>\u0b95\u0bbf\u0bb3\u0bbe\u0ba9\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0baa\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison.webp\" alt=\"MV \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b83\u0baa\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bcd, \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bb5\u0b9a\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9c\u0bcb\u0b9f\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b95\u0bb5\u0b9a\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\" class=\"wp-image-3675\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-shield-types-comparison-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd (MV) \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b83\u0baa\u0bbe\u0baf\u0bbf\u0bb2\u0bcd, \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bb5\u0b9a \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1.<\/figcaption><\/figure>\n<h2>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf \u0bb5\u0b95\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd<\/h2>\n<h3>\u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3 \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bb2\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0bb5\u0b95\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0bb2\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0b9f\u0bcd\u0b9f \u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bcd<\/strong> (4-20mA \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, RTD \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bc6\u0bb0\u0bcd\u0bae\u0bcb\u0b95\u0baa\u0bcd\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd) \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bbe\u0baf\u0bcd\u0bb5\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bbe\u0baf\u0bcd\u0bb5\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0ba3\u0bb0\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd SCADA \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p><strong>\u0b9f\u0bbf\u0b9c\u0bbf\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bcd<\/strong> (\u0bb0\u0bbf\u0bb2\u0bc7 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bc1\u0ba3\u0bc8 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd, \u0ba8\u0bbf\u0bb2\u0bc8 \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bcd) \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd (24-125VDC \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 110-240VAC) \u0b85\u0ba4\u0bbf\u0b95 \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, 100 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0ba8\u0bc0\u0bb3\u0bae\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0ba4\u0bbf\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd, \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/strong> (\u0b88\u0ba4\u0bb0\u0bcd\u0ba8\u0bc6\u0b9f\u0bcd, \u0b9a\u0bc0\u0bb0\u0bbf\u0baf\u0bb2\u0bcd RS-485, IEC 61850 GOOSE \u0bae\u0bc6\u0b9a\u0bc7\u0b9c\u0bbf\u0b99\u0bcd) 100 Mbps \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc7\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b95\u0bb5\u0b9a \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba8\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb3\u0bb5\u0bc1, \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0ba4\u0bc1. \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bb5\u0bc8:<\/p>\n<ul>\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong>CT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, \u0b9a\u0bc1\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 1% \u0bb5\u0bcb\u0bb2\u0bcd\u0b9f\u0bc7\u0b9c\u0bcd \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9\u0ba4\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<li><strong>\u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd<\/strong>\u0baa\u0bbf\u0bb4\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, CT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb2\u0bbf\u0bae\u0bc8<\/strong>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 1.5mm\u00b2 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 2.5mm\u00b2) \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable.webp\" alt=\"IEC 60332, IEC 61034, IEC 60754, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd IEC 60331 \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 IEC \u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd.\" class=\"wp-image-3676\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/iec-fire-rating-tiers-control-cable-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b85\u0bb1\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf IEC \u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0b9f\u0bbf\u0ba8\u0bbf\u0bb2\u0bc8.<\/figcaption><\/figure>\n<h2>\u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n<h3>MV \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b86\u0ba4\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n<p>MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bb5\u0bbe\u0bb2\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bc8 \u0bae\u0bc1\u0ba9\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bc1:<\/p>\n<p><strong>\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0baf \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1<\/strong> \u0baa\u0bbf\u0bb4\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0bb9\u0bbe\u0bb0\u0bcd\u0bae\u0bcb\u0ba9\u0bbf\u0b95\u0bcd\u0bb8\u0bcd, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0b85\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc2\u0bae\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0baf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bc8\u0bb5\u0bcd\u0b95\u0bb3\u0bcd, \u0baa\u0bb5\u0bb0\u0bcd \u0b8e\u0bb2\u0b95\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0ba9\u0bbf\u0b95\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba8\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bc6\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd \u0baa\u0bc7\u0b99\u0bcd\u0b95\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b99\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b89\u0baf\u0bb0\u0bcd-\u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0baa\u0b95\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bc2\u0bae\u0bbf \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b95\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc0\u0b9a\u0bcd\u0b9a\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bc8<\/strong> \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bb8\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb8\u0bcd, \u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b83\u0baa\u0bbf\u0bb3\u0bbe\u0bb7\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd, \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0bb0\u0bc7\u0b9f\u0bbf\u0baf\u0bcb \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0bae\u0bc2\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc0\u0b9a\u0bcd\u0b9a\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bb8\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bb3\u0b9a\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1<\/strong> \u0b89\u0baf\u0bb0\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0b9a\u0bbf\u0bb5\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 SF6-\u0b86\u0bb2\u0bcd \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb1\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bc1-\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb1\u0bcd\u0bb1\u0b9f\u0bcd \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bbf\u0bb2\u0bcd (GIS) \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0baf\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bb5\u0b9a \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd<\/h3>\n<p><strong>\u0ba4\u0b95\u0b9f\u0bc1 \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> (\u0b85\u0bb2\u0bc1\u0bae\u0bbf\u0ba9\u0bbf\u0baf\u0bae\u0bcd-\u0baa\u0bbe\u0bb2\u0bbf\u0baf\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd \u0bb2\u0bc7\u0bae\u0bbf\u0ba9\u0bc7\u0b9f\u0bcd) 100% \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 1 MHz-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b89\u0baf\u0bb0\u0bcd-\u0b86\u0935\u0943\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0b99\u0bcd\u0b95\u0bb2\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0ba9\u0bcd \u0bae\u0bc6\u0bb2\u0bcd\u0bb2\u0bbf\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b86\u0935\u0943\u0ba4\u0bcd\u0ba4\u0bbf \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2 \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc7 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b83\u0baa\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0baf\u0bb0\u0bcd-\u0b87\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p><strong>\u0bae\u0bc1\u0b9f\u0bbf\u0b9a\u0bcd\u0b9a\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> (\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bc2\u0b9a\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 85-95% \u0bae\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1) \u0b83\u0baa\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b85\u0bb2\u0bc8\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0ba8\u0bc6\u0b95\u0bbf\u0bb4\u0bcd\u0bb5\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 1 MHz \u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7\u0baf\u0bbe\u0ba9 \u0b85\u0bb2\u0bc8\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0b87\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc6\u0b9f\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd, CT\/VT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bbe\u0b95 \u0b86\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> (\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd) \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0ba8\u0bcd\u0ba4 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, MV \u0baa\u0bc7\u0bb8\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0bb0\u0bc1\u0b95\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0b85\u0ba4\u0bbf\u0b95 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4 \u0b95\u0bb2\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bb5\u0b9a\u0bae\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9c\u0bcb\u0b9f\u0bbf\u0b95\u0bb3\u0bcd\/\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9f\u0bbf\u0b9c\u0bbf\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb2\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9, \u0b92\u0bb0\u0bc7 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bbf\u0baf\u0bb5\u0bbe\u0bb1\u0bc1, \u0baa\u0bb2 \u0bb5\u0b95\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0b95\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bb5\u0b9a \u0bae\u0ba3\u0bcd\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0b9f\u0bc8\u0baf\u0bc7 \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb5\u0bbe\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0b95\u0bb3 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd (IEEE 1143, IEC 62271-1) \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bc7\u0ba9\u0bcd:<\/p>\n<p><strong>\u0b92\u0bb1\u0bcd\u0bb1\u0bc8-\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0bae\u0ba3\u0bcd\u0ba3\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd<\/strong> \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b95\u0bb5\u0b9a \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba8\u0bc0\u0bb0\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc0\u0bb0\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0ba4\u0bca\u0bb2\u0bc8 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0baa\u0bb2\u0bcd\u0baa\u0baf\u0bbf\u0bb0\u0bcd \u0bae\u0ba3\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0baa\u0bb2 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0b89\u0baf\u0bb0\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bc8 \u0bae\u0bbf\u0b95\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb2\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95 \u0b85\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0b95\u0bb5\u0bb2\u0bc8\u0baf\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9f\u0bbf\u0b9c\u0bbf\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0ba3\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bb5\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0baf\u0bb0\u0bcd-\u0b86\u0935\u0943\u0924\u094d\u0924\u093f \u0baa\u0bc8\u0baa\u0bbe\u0bb8\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95\u0bbf\u0b95\u0bb3\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 10-100nF) \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b89\u0baf\u0bb0\u0bcd-\u0b86\u0935\u0943\u0924\u094d\u0924\u093f \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b86\u0935\u0943\u0924\u094d\u0924\u093f \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation.webp\" alt=\"MV \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd, LV \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9f\u0bbf\u0bb0\u0bc7\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc2\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9f\u0bbf\u0bb0\u0bc7 \u0ba4\u0bb3\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" class=\"wp-image-3677\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-panel-control-cable-routing-separation-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b85\u0bb1\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9f\u0bbf\u0bb0\u0bc7 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd.<\/figcaption><\/figure>\n<h2>\u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd<\/h3>\n<p>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0bb2 \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<p><strong>\u0ba4\u0bc0 \u0baa\u0bb0\u0bb5\u0bb2\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong> (IEC 60332 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd) \u0b92\u0bb0\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bbf\u0ba9\u0bcd \u0ba8\u0bc0\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa \u0ba4\u0bc0 \u0baa\u0bb0\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. IEC 60332-1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b9a\u0bc1\u0b9f\u0bb0\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd IEC 60332-3 \u0baf\u0ba4\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0ba4\u0bbf\u0ba8\u0bbf\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb0\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 A (\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd) 3.5 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc1\u0b9f\u0bb0\u0bcd \u0baa\u0bb0\u0bb5\u0bc1\u0ba4\u0bb2\u0bc8 2.5 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0bc0 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd<\/strong> (IEC 60331) \u0ba4\u0bc0 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0baa\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd, 750\u00b0C \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bc0\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b89\u0b9f\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u2014\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 90 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 120 \u0ba8\u0bbf\u0bae\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0baa\u0bc1\u0b95\u0bc8 \u0b85\u0b9f\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf<\/strong> (IEC 61034) \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b8e\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bc1\u0b95\u0bc8 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 60% \u0b92\u0bb3\u0bbf \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0baf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<p><strong>\u0bb9\u0bbe\u0bb2\u0bcb\u0b9c\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bbf\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd<\/strong> (IEC 60754) \u0bae\u0ba9\u0bbf\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bc1\u0b95\u0bc8 \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0bb9\u0bbe\u0bb2\u0bcb\u0b9c\u0ba9\u0bcd (LSZH) \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba4 \u0b8e\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bbf, \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0bae\u0bbf\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0bb5\u0bbf\u0ba3\u0bcd\u0ba3\u0baa\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc7\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0baa\u0bb2\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<p><strong>\u0baa\u0baf\u0ba9\u0bc1\u0bb1\u0bc1\u0ba4\u0bbf \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd IEC 60332-3 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 C \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bc2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd, \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bc0\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n<p><strong>\u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong> \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bbf\u0baf \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd LSZH \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bc6\u0b9f\u0bcd\u0bb0\u0bcb\u0b95\u0bc6\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b86\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b85\u0bb5\u0b9a\u0bb0 \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc0\u0baf\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b85\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bb0\u0bc1 \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b86\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf, \u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0bc1\u0b9f\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b85\u0bb5\u0b9a\u0bb0 \u0b8a\u0b9f\u0bcd\u0b9f\u0ba8\u0bc0\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc0\u0baf\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8 (IEC 60331) \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b95\u0bc0\u0bb4\u0bcd\u0bae\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/strong> (\u0b95\u0bae\u0bcd\u0baa\u0bbf \u0b9a\u0bc1\u0bb0\u0b99\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd) \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0bb5\u0bc8 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, '\u0b8f' \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 \u0ba4\u0bc0 \u0baa\u0bb0\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices.webp\" alt=\"\u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 EMC \u0b95\u0bbf\u0bb3\u0bbe\u0ba3\u0bcd\u0b9f\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b9f\u0ba9\u0bcd, \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4 \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b83\u0baa\u0bc6\u0bb0\u0bc2\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0bae\u0bcd.\" class=\"wp-image-3678\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/mv-control-cable-termination-practices-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 EMC \u0b95\u0bbf\u0bb3\u0bbe\u0ba3\u0bcd\u0b9f\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b89\u0b9f\u0bcd\u0baa\u0b9f.<\/figcaption><\/figure>\n<h2>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc0\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n<p><strong>\u0b89\u0b9f\u0bb2\u0bcd\u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 300 \u0bae\u0bbf\u0bae\u0bc0 \u0bb5\u0bbf\u0ba4\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0b85\u0ba4\u0bbe\u0bb5\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 300 \u0bae\u0bbf\u0bae\u0bc0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0bc6\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b89\u0bb2\u0bcb\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. 15kV-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bc2\u0bb0\u0bae\u0bcd \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bbe\u0b9a\u0bbe\u0bb0\u0bae\u0bbe\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bcb\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, 90 \u0b9f\u0bbf\u0b95\u0bbf\u0bb0\u0bbf \u0b95\u0bcb\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bbe\u0baf\u0bcd\u0ba4\u0bb3\u0b95\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b85\u0bb5\u0bc8 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p><strong>\u0b9a\u0bc6\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f\u0bae\u0bcd<\/strong> \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b85\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bb0\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc2\u0bb0\u0bc8 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bc0 \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0bb5\u0ba4\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf, \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb0\u0ba4\u0bcd\u0ba4\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b87\u0ba3\u0b95\u0bcd\u0b95 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b8e\u0bb3\u0bbf\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p>\u0bb8\u0bcd\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0bb5\u0bb0\u0bbf\u0b9a\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0ba4\u0bc2\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b85\u0ba4\u0bc7 \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0b86\u0bb2\u0bc8 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd; \u0b92\u0bb0\u0bc1 <a href=\"https:\/\/xmqj.com\/\" target=\"_blank\" rel=\"noopener\">\u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9f\u0bbf\u0bb0\u0bc7 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a> \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd MV \u0baa\u0bc7\u0ba9\u0bb2\u0bc8 \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bbf\u0baf \u0baa\u0bbf\u0bb1\u0b95\u0bc1, \u0ba4\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bcd, \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf, \u0ba4\u0bc0 \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb0\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b9a\u0bc0\u0bb0\u0bbe\u0b95 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb0\u0bae\u0bcd \u0baa\u0bb0\u0bbf\u0b9a\u0bc0\u0bb2\u0ba9\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb0\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd, \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<ul>\n<li><strong>\u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd<\/strong>: \u0b92\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 6 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1<\/li>\n<li><strong>\u0b95\u0bb5\u0b9a\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd<\/strong>: \u0b92\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 12 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1<\/li>\n<li><strong>\u0ba8\u0bbe\u0bb0\u0bcd \u0b92\u0bb3\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0bb2\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd<\/strong>\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf, \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bcd 15-20 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1<\/li>\n<\/ul>\n<p>\u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb0\u0bae\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1, \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bc0\u0bb3\u0bae\u0b9f\u0bc8\u0ba4\u0bb2\u0bcd, \u0b95\u0bb5\u0b9a \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0b9f\u0bc8\u0ba4\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0bcd\u0b9f \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bb1\u0bc8\u0bae\u0bc1\u0b95 \u0b9a\u0bc7\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bb2 \u0ba4\u0b9f\u0bb5\u0bc8 \u0ba8\u0bbf\u0b95\u0bb4\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8\u0b95\u0bb3\u0bc8, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b95\u0bc2\u0bb0\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0ba8\u0bbe\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3\u0bc7\u0ba9\u0bcd.<\/p>\n<h3>\u0b95\u0bae\u0bcd\u0baa\u0bbf \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd, \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b86\u0ba4\u0bb0\u0bb5\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf, \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba3\u0bc1\u0b95\u0bb2\u0bc8 \u0b88\u0b9f\u0bc1\u0b95\u0b9f\u0bcd\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:<\/p>\n<p><strong>\u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba4\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong> \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd (\u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 40%, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 50%) \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbe\u0bae\u0bcd. \u0ba4\u0bbf\u0b9f\u0bae\u0bbe\u0ba9 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f, \u0b8f\u0ba3\u0bbf \u0bb5\u0b95\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0b8e\u0bb3\u0bbf\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p><strong>\u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baa\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bb3\u0bcd<\/strong> \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf-\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba8\u0b95\u0bb0\u0bcd\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0bcd\u0bb3\u0bbf\u0baf\u0b9f\u0bcd \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, CT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b87\u0baf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0bc1\u0bb4\u0bbe\u0baf\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong> \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0ba3 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b87\u0b9f\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bae\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0bbf\u0bb0\u0bb5 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bbe\u0ba4 \u0ba8\u0bc6\u0b95\u0bbf\u0bb4\u0bcd\u0bb5\u0bbe\u0ba9 \u0b89\u0bb2\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb4\u0bbe\u0baf\u0bcd, \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bc8 \u0bae\u0bb1\u0bc1\u0bb5\u0bb4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd\u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<h2>\u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1<\/h3>\n<p>\u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0bb2 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n<p><strong>\u0b87\u0bb2\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b8f\u0bb1\u0bcd\u0bb1 \u0b87\u0bb1\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bae\u0bb2\u0bcd \u0b9a\u0bc0\u0bb0\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b85\u0bb5\u0bcd\u0bb5\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb8\u0bcd\u0baa\u0bbf\u0bb0\u0bbf\u0b99\u0bcd \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bbf\u0baf \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bc1 \u0bb5\u0b95\u0bc8 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b95\u0ba3\u0bcd\u0ba3\u0bbe\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba8\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bc1\u0bae\u0bcd. \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/p>\n<p><strong>\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0b87\u0b9f\u0baa\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bcd (IDC)<\/strong> \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b87\u0ba4\u0bc1 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb3\u0bb5\u0bc1 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b87\u0ba4\u0bc1 \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0baf\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 IDC \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9\u0bb5\u0bc8.<\/p>\n<h3>\u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<p><strong>\u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bbe\u0bb2\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0ba4\u0bc7\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b85\u0b9a\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd, \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bbe\u0bae\u0bb2\u0bcd, \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0baa\u0bc6\u0bb1\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bb3\u0bb0\u0bcd\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<p><strong>\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0ba8\u0bb0\u0bcd \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0b9f\u0bcd\u0b9f\u0bc8 \u0ba8\u0bc0\u0bb3\u0bae\u0bcd (\u0b95\u0bc1\u0bb4\u0bbe\u0baf\u0bcd\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd), \u0b95\u0bae\u0bcd\u0baa\u0bbf \u0b87\u0bb4\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 (\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc7 \u0b9a\u0bc6\u0ba9\u0bcd\u0bb1 \u0b87\u0bb4\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc2\u0baf\u0bcd\u0bae\u0bc8 (\u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0b95\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b9a\u0bc1\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/strong> \u0b87\u0ba4\u0bc1 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b9f\u0bc8 \u0bae\u0bc2\u0b9f\u0bb2\u0bcd, \u0bae\u0bc8\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc0\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0b9a\u0bcd\u0b9a\u0bc6\u0bb0\u0bc1\u0b95\u0bb2\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0ba4\u0bc1. \u0baa\u0bb2 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b95\u0bcd\u0bb0\u0bbf\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd 100% \u0b86\u0baf\u0bcd\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b95\u0bb5\u0b9a \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b95\u0bb5\u0b9a \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0bae\u0bcd, \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n<p><strong>360-\u0baa\u0bbe\u0b95\u0bc8 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf<\/strong> EMC \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b95\u0bcd\u0bb3\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bb3\u0bb5\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8 10 MHz-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bbf\u0b95\u0bcd\u0b9f\u0bc6\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f 40-60 dB \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0baa\u0bbf\u0b95\u0bcd\u0b9f\u0bc6\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong> (\u0b95\u0bb5\u0b9a \u0bb5\u0b9f\u0bbf\u0b95\u0bbe\u0bb2\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd \u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1) \u0b8e\u0bb3\u0bbf\u0bae\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bbf\u0ba9\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b89\u0baf\u0bb0\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd \u0ba4\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bc8\u0b95\u0bcd\u0b9f\u0bc6\u0baf\u0bbf\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0ba8\u0bc0\u0bb3\u0ba4\u0bcd\u0ba4\u0bc8 50 \u0bae\u0bbf\u0bae\u0bc0-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bb4\u0bbf\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b95\u0bb5\u0b9a\u0baa\u0bcd \u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/strong> \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bb5\u0b9a \u0bae\u0bc1\u0ba9\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b9a\u0bae\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc8 \u0b8e\u0bb3\u0bbf\u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bb2 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bb2\u0b95\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95\u0bb5\u0bc7 \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95\u0bae\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbe\u0b9f\u0bc1\u0bb2\u0bb0\u0bcd \u0b95\u0bb5\u0b9a \u0bae\u0bc1\u0ba9\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb0\u0bcd.<\/p>\n<hr \/>\n<h2>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/h3>\n<p>\u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:<\/p>\n<p><strong>\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong> \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 500VDC-\u0b87\u0bb2\u0bcd, \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bbf\u0bb2\u0bcb\u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 100 M\u03a9-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb0\u0bbe\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bbe\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bbe\u0bb2\u0bcd, \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1, \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc7 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong> \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, EMC \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b95\u0bb5\u0b9a \u0b89\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bbf\u0baf\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0bb5\u0bc7\u0bb2\u0bc8\u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0bb1\u0bcd\u0bb1 \u0baa\u0bbf\u0bb1\u0b95\u0bc1:<\/p>\n<p><strong>\u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bc1\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/strong> \u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0ba8\u0b9f\u0bc8\u0baa\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b87\u0bb4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8, \u0b95\u0bc2\u0bb0\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0bae\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1-\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong> \u0b9a\u0bc1\u0bae\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd, \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd. \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f 1%-\u0b90\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bae\u0bb1\u0bc1-\u0ba4\u0bbf\u0b9a\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/strong> \u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bc2\u0b9a\u0bbf \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1, \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b95\u0bb5\u0b9a \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<h2>\u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bb3\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0baa\u0bc6\u0b9f\u0bcd\u0bb0\u0bcb\u0b95\u0bc6\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0bb5\u0b9a\u0ba4\u0bbf \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/h3>\n<p>\u0b95\u0bbe\u0bb2\u0bcd\u0b83\u0baa\u0bcd \u0b95\u0b9f\u0bb1\u0bcd\u0b95\u0bb0\u0bc8 \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bae\u0bc0\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 13.8kV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b9c\u0bbf\u0baf\u0bb0\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bbe\u0bb3\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0bbf\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba9. \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b9f\u0bbf\u0bb0\u0bc8\u0bb5\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f CT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0bb5\u0b9f\u0bbf\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0bb1\u0bbf\u0baf \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1. \u0b87\u0ba4\u0bc1 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b85\u0bae\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1.<\/p>\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bbf\u0bb2\u0bcd, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 CT \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f, \u0b95\u0bb2\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0b9f\u0bc1\/\u0bae\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bb5\u0b9a\u0bae\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0ba4\u0bb2\u0bcd, \u0b87\u0bb0\u0bc1 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd 360-\u0b9f\u0bbf\u0b95\u0bbf\u0bb0\u0bbf \u0b95\u0bb5\u0b9a \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd VFD \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 450 \u0bae\u0bbf\u0bae\u0bc0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8 \u0b85\u0b9f\u0bc8\u0baf \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bb1\u0bc1\u0bb5\u0bb4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bbf\u0baf\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba9. \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd 850mV \u0b89\u0b9a\u0bcd\u0b9a\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 15mV-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u2014\u0b85\u0ba4\u0bbe\u0bb5\u0ba4\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0b95\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd\u2014\u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0ba9.<\/p>\n<h3>\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bbe\u0ba9\u0bae\u0bcd<\/h3>\n<p>\u0baa\u0bbf\u0bb0\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0 \u0bb5\u0bbf\u0baa\u0ba4\u0bcd\u0ba4\u0bc1 \u0b9a\u0bae\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b95\u0bb5\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 230\/34.5kV \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0baf\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bb5\u0bc8:<\/p>\n<ul>\n<li>\u0baa\u0bbe\u0b95\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb8\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 IEC 60331-\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<li>\u0bae\u0bb1\u0bcd\u0bb1 \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd IEC 60332-3 \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 A \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<li>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b99\u0bcd\u0b95\u0bc0\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0b9a\u0bbf\u0b9f\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0ba4\u0bc0 \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1.<\/li>\n<\/ul>\n<p>18 \u0bae\u0bbe\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bb4\u0bae\u0bc8\u0bb5\u0bbe\u0ba4 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<h2>\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0b95\u0bc71: \u0b8e\u0ba9\u0ba4\u0bc1 MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0bb5\u0bc8\u0baf\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/h3>\n<p>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd 300 \u0bae\u0bbf\u0bae\u0bc0-\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b85\u0ba9\u0bb2\u0bbe\u0b95\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bcd (1V \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc8\u0b95\u0bcd\u0bb0\u0bcb\u0b86\u0bae\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bb0\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9\u0bb5\u0bc8) \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bc6\u0bb1\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f EMC \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bbf\u0bb2\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b9f\u0bbf\u0bb0\u0bc8\u0bb5\u0bcd\u0b95\u0bb3\u0bcd, \u0b86\u0bb0\u0bcd\u0b95\u0bcd \u0b89\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bbf\u0bb1 \u0b89\u0baf\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bc2\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bc1\u0ba4\u0bbf\u0baf MV \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1, \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1 \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0ba9\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bc72: \u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bb0\u0bc8, LSZH \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 PVC \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/h3>\n<p>LSZH (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bc1\u0b95\u0bc8 \u0baa\u0bc2\u0b9c\u0bcd\u0b9c\u0bbf\u0baf \u0bb9\u0bbe\u0bb2\u0bcb\u0b9c\u0ba9\u0bcd) \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd, \u0b8e\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bc1\u0b95\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bc1\u0b95\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b85\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bbf\u0bb2 \u0bb5\u0bbe\u0baf\u0bc1\u0b95\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0b9f\u0bbe\u0ba4 \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0baa\u0bbe\u0bb2\u0bbf\u0baf\u0bcb\u0bb2\u0bbf\u0b83\u0baa\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 PVC \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0b95\u0bc1\u0bb3\u0bcb\u0bb0\u0bc8\u0b9f\u0bc1 \u0bb5\u0bbe\u0baf\u0bc1\u0bb5\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0bcb\u0b95\u0bc1\u0bb3\u0bcb\u0bb0\u0bbf\u0b95\u0bcd \u0b85\u0bae\u0bbf\u0bb2\u0bae\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bbf, \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b9a\u0bc1\u0bb5\u0bbe\u0b9a \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. LSZH \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 PVC \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f 15-25% \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb2\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8, \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0b9a\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0ba8\u0bbf\u0baf\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b95\u0bc73: \u0b9f\u0bbf\u0b9c\u0bbf\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc7 \u0b95\u0bbe\u0ba9\u0bcd\u0b9f\u0bbf\u0ba9\u0bbf\u0baf\u0bc2\u0bb5\u0bbf\u0bb2\u0bcd CT \u0b9a\u0bc6\u0b95\u0bcd\u0b95\u0ba3\u0bcd\u0b9f\u0bb0\u0bbf \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/h3>\n<p>\u0b86\u0bae\u0bcd, \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc6\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd. \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0bc1\u0bb2 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95, CT \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0bc1\u0bb4\u0bbe\u0baf\u0bcd \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. \u0baa\u0bbf\u0bb4\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd\u2014\u0bae\u0bbf\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 CT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b85\u0bb3\u0bb5\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bbf\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b89\u0ba4\u0bcd\u0ba4\u0bb0\u0bb5\u0bbe\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bc74: IEC 61850 GOOSE \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0ba8\u0bcd\u0ba4 \u0b95\u0bb5\u0b9a \u0bae\u0ba3\u0bcd\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/h3>\n<p>IEC 61850 GOOSE (\u0b9c\u0bc6\u0ba9\u0bb0\u0bbf\u0b95\u0bcd \u0b86\u0baa\u0bcd\u0b9c\u0bc6\u0b95\u0bcd\u0b9f\u0bcd \u0b93\u0bb0\u0bbf\u0baf\u0ba9\u0bcd\u0b9f\u0b9f\u0bcd \u0b9a\u0baa\u0bcd\u0bb8\u0bcd\u0b9f\u0bc7\u0bb7\u0ba9\u0bcd \u0b88\u0bb5\u0bc6\u0ba9\u0bcd\u0b9f\u0bcd) \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b88\u0ba4\u0bb0\u0bcd\u0ba8\u0bc6\u0b9f\u0bcd \u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0baa\u0bbf\u0bb0\u0bbe\u0b9f\u0bcd\u0baa\u0bc7\u0ba3\u0bcd\u0b9f\u0bcd \u0b87\u0bb0\u0bc8\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bbf\u0ba9\u0bcd \u0b87\u0bb0\u0bc1 \u0bae\u0bc1\u0ba9\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba8\u0bcd\u0ba4\u0bb5\u0bca\u0bb0\u0bc1 \u0b87\u0b9f\u0bc8\u0ba8\u0bbf\u0bb2\u0bc8 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0bb2-\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0b95\u0bb5\u0b9a \u0bae\u0ba3\u0bcd\u0ba3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b89\u0b95\u0ba8\u0bcd\u0ba4 \u0b89\u0baf\u0bb0\u0bcd-\u0b85\u0bb2\u0bc8\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bb5\u0b9a\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd, \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b95\u0bb5\u0b9a\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0ba3\u0bcd\u0ba3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b87\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0baf\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bc75: \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0bb1\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/h3>\n<p>\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bc1 \u0bb5\u0b95\u0bc8 \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 (\u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95 24-48 \u0bae\u0ba3\u0bbf\u0ba8\u0bc7\u0bb0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1), \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 3-5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc1, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bbf\u0b95-\u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bbe\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd. \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bae\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bc1-\u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba3\u0bc1\u0b95\u0bb2\u0bcd \u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bbe\u0ba9 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb5\u0bc8 \u0baa\u0bc6\u0bb0\u0bc1\u0b95\u0bbf\u0baf \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b95\u0bc76: MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/h3>\n<p>\u0b85\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb5\u0b9a\u0bbf\u0baf \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0bbe\u0ba9 \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0b99\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0bbe\u0bb3\u0bae\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0b95\u0bb3\u0bcd, \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf \u0bb5\u0ba3\u0bcd\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd (\u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bcb\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2) '\u0b86\u0bb8\u0bcd-\u0baa\u0bbf\u0bb2\u0bcd\u0b9f\u0bcd' \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8f\u0ba4\u0bc7\u0ba9\u0bc1\u0bae\u0bcd \u0b95\u0bb5\u0b9a \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbe\u0bb3\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0baa\u0bb4\u0bc1\u0ba4\u0bc1\u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd, \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0ba4\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bbf\u0bb2\u0bc8\u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bb5\u0bc8\u0baf\u0bbe\u0b95 \u0ba8\u0bbf\u0bb0\u0bc2\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b95\u0bc77: \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf?<\/h3>\n<p>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 IP (\u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1) \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0b95\u0bbf\u0bb3\u0bbe\u0ba9\u0bcd\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u2014\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 MV \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd IP66 \u0ba4\u0bc7\u0bb5\u0bc8. \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bbf, \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b9a\u0bc0\u0bb2\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0bb9\u0bc6\u0bb0\u0bcd\u0bae\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd \u0b9a\u0bc0\u0bb2\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1, \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0b89\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0b9f\u0bbf\u0b95\u0bbe\u0bb2\u0bcd \u0bb5\u0b9a\u0ba4\u0bbf\u0baf\u0bc8 (\u0ba4\u0bbe\u0bb4\u0bcd\u0bb5\u0bbe\u0ba9 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bb5\u0b9f\u0bbf\u0b95\u0bbe\u0bb2\u0bcd \u0ba4\u0bc1\u0bb3\u0bc8\u0b95\u0bb3\u0bcd) \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0bb9\u0bc6\u0bb0\u0bcd\u0bae\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd \u0b9a\u0bc0\u0bb2\u0bbf\u0b99\u0bcd \u0ba4\u0bb5\u0bbf\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd. \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bc7 \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bae\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd '\u0baa\u0bbf\u0bb0\u0bc0\u0ba4\u0bbf\u0b99\u0bcd \u0b8e\u0bb2\u0bbf\u0bae\u0bc6\u0ba9\u0bcd\u0b9f\u0bcd'\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb5\u0bc1\u0bae\u0bcd. \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0bb2\u0b95\u0bcd\u0b95\u0bbf \u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b9c\u0bc6\u0bb2\u0bcd \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<hr \/>\n<h2>\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8: \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bae\u0bcd\u0baa\u0bbf\u0b9a\u0bcd\u0b9a\u0bb0\u0b9f\u0bc1 \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n<p>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bb2 \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:<\/p>\n<p><strong>\u0b95\u0bb5\u0b9a\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/strong> \u0ba4\u0b9f\u0bc8 \u0bae\u0bc2\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1, \u0b9a\u0bbf\u0b95\u0bcd\u0ba9\u0bb2\u0bcd \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1, \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b95\u0bb5\u0b9a \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bc2\u0bae\u0bbf \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b85\u0bb0\u0bbf\u0ba4\u0bbe\u0b95\u0bb5\u0bc7 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0ba9\u0bb5\u0bc1\u0b95\u0bcd \u043a\u043e\u0448\u0bae\u0bbe\u0bb0\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0bc0 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bbe\u0bb0 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/strong> \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0bae\u0bcd, \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb5\u0bbf\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0ba4\u0bc0 \u0baa\u0bb0\u0bb5\u0bb2\u0bcd, \u0ba4\u0bc0 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd, \u0baa\u0bc1\u0b95\u0bc8 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb9\u0bbe\u0bb2\u0bcb\u0b9c\u0ba9\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd. \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b89\u0b9f\u0bcd\u0baa\u0b9f, \u0b92\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bca\u0ba4\u0bcd\u0ba4 \u0ba4\u0bc0 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0bb5\u0bb4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b92\u0bb4\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong> \u0baa\u0bbf\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0b86\u0bb0\u0bae\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bbf\u0baf\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0b86\u0ba4\u0bb0\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd. \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bc1\u0baf\u0bb1\u0bcd\u0b9a\u0bbf, \u0baa\u0bb2 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbe\u0bb2\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong> \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b9f\u0bc6\u0bb0\u0bcd\u0bae\u0bbf\u0ba9\u0bb2\u0bcd \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1, \u0b95\u0bbf\u0bb0\u0bbf\u0bae\u0bcd\u0baa\u0bcd\u0bb8\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1, \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b95\u0bb5\u0b9a\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bb5\u0b9a \u0bae\u0bc1\u0ba9\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong> \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bcd, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0b9a\u0bcd\u0b9a\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n<p>\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bcd MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0bbf\u0baf \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bc7 \u0b86\u0ba9\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b89\u0bb0\u0bbf\u0baf \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b95\u0bb5\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bc1\u0ba4\u0bb2\u0bc0\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1\u0bae\u0bcd, \u0ba4\u0bb0\u0bae\u0bbe\u0ba9 \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd, \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 30-40 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc1\u0bb5\u0bbe\u0baf\u0bc8 \u0b88\u0b9f\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bb0\u0bc1\u0bae\u0bcd.<\/p>\n<h2>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<ul>\u0b93\u0b9f\u0bc1\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0ba9\u0bae\u0bcd, \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0b9a\n<li><a href=\"https:\/\/xbrele.com\/ta\/switchgear-component-manufacturers-buyer-guide\/\">\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bb0\u0bcd \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/switchgear\/\">\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bb3\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/\">\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0b95\u0bb0\u0bc1\u0bb5\u0bbf \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0bbf\u0b95\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/99635\" target=\"_blank\" rel=\"noopener\">IEC 62271-100 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc7\u0baa\u0bbf\u0bb3\u0bcd\u0b95\u0bb3\u0bc8, \u0bb7\u0bc0\u0bb2\u0bcd\u0b9f\u0bbf\u0b99\u0bcd, \u0ba4\u0bc0 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1, \u0bb5\u0bb4\u0bbf\u0ba4\u0bcd\u0ba4\u0b9f\u0bae\u0bcd, \u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd EMC \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>","protected":false},"author":3,"featured_media":3674,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3679","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3679","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=3679"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3679\/revisions"}],"predecessor-version":[{"id":4113,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3679\/revisions\/4113"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/3674"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=3679"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=3679"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=3679"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}