{"id":3685,"date":"2026-04-13T05:30:45","date_gmt":"2026-04-13T05:30:45","guid":{"rendered":"https:\/\/xbrele.com\/?p=3685"},"modified":"2026-05-25T14:29:00","modified_gmt":"2026-05-25T14:29:00","slug":"relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter\/","title":{"rendered":"MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd: 50\/51\/50N\/51N\/27\/59\/86 \u2013 \u0b85\u0bb5\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9"},"content":{"rendered":"<h2>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/h2>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3681\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01.webp\" alt=\"MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-01-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0bae\u0bcd<\/h2>\n<p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (MV) \u0bae\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0ba9\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, \u0b89\u0baa\u0b95\u0bb0\u0ba3 \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb0\u0ba3\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0b95\u0bb5\u0bb2\u0bcd\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bc1, \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd, \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<p>\u0baa\u0bc6\u0b9f\u0bcd\u0bb0\u0bcb\u0b95\u0bc6\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd \u0b86\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0ba4\u0bb0\u0bb5\u0bc1 \u0bae\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd MV \u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd\u0b95\u0bbf\u0baf\u0bb0\u0bc8 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bbf\u0bb2\u0bcd \u0b8e\u0ba9\u0ba4\u0bc1 18 \u0bb5\u0bb0\u0bc1\u0b9f \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0b95 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bc7\u0ba9\u0bcd. \u0bae\u0bbe\u0bb1\u0bbe\u0b95, \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9f\u0bbe\u0bb2\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bae\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0b95, \u0b95\u0bbe\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9.<\/p>\n<p>\u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bb0\u0bc8 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0ba9\u2014ANSI \u0b9a\u0bbe\u0ba4\u0ba9 \u0b8e\u0ba3\u0bcd\u0b95\u0bb3\u0bcd 50, 51, 50N, 51N, 27, 59, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 86\u2014\u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd, \u0b85\u0bb5\u0bc8 MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bc0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0b89\u0bb3\u0bcd\u0bb3 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bb3 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb2\u0bcd\u0bb2\u0bc1\u0ba8\u0bb0\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf, \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bb0\u0bc8 \u0b89\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3682\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02.webp\" alt=\"MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-02-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 1: ANSI \u0b9a\u0bbe\u0ba4\u0ba9 \u0b8e\u0ba3\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd<\/h2>\n<p>\u0b87\u0ba9\u0bcd\u0b9f\u0bb0\u0bcd\u0bb2\u0bbe\u0b95\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bc2\u0bb4\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd, \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf \u0b92\u0bb0\u0bc1 \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0ba9 \u0baa\u0bc1\u0bb0\u0bbf\u0ba4\u0bb2\u0bc8 \u0ba8\u0bbe\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. ANSI\/IEEE C37.2 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bbf\u0baf\u0bbf\u0baf\u0bb2\u0bbf\u0ba9\u0bcd \u0b89\u0bb2\u0b95\u0bb3\u0bbe\u0bb5\u0bbf\u0baf \u0bae\u0bca\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bbf\u0baf \u0b9a\u0bbe\u0ba4\u0ba9 \u0b8e\u0ba3\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 (50\/51)<\/h3>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 50 (\u0ba8\u0bca\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd)<\/strong> \u0bae\u0bc1\u0ba9\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bc6\u0ba9\u0bcd\u0bb1\u0bc7 \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bbf\u0ba9\u0bcd\u0bb1\u0bbf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0b9a\u0bcd \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 6 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 10 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd, \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 1.5 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 2 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bc6\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0baf \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0b95\u0bc2\u0bb1\u0bc1 \u0b85\u0ba4\u0bbf\u0bb5\u0bc7\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 51 (\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0bae\u0bcd)<\/strong> \u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd-\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0baa\u0ba3\u0bcd\u0baa\u0bc8 \u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bb0\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd (IEC \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd, \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd, \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 IEEE \u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd, \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd, \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd) \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0ba8\u0bbf\u0bb2\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 (50N\/51N)<\/h3>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 50N (\u0ba8\u0bca\u0b9f\u0bbf\u0baf\u0b95\u0bb5\u0bc1\u0ba3\u0bcd\u0b9f\u0bb0\u0bcd \u0bae\u0ba3\u0bcd \u0bae\u0bc0\u0ba4\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd)<\/strong> \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95 \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0baa\u0bbf\u0b95\u0bcd-\u0b85\u0baa\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 10 \u0bae\u0bc1\u0ba4\u0bb2\u0bcd 20% \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd CT \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1-\u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0b9f\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0ba4\u0bcd\u0ba4\u0bbf\u0b9a\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 51N (\u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bc2\u0bae\u0bbf)<\/strong> \u0baa\u0bb2 \u0baa\u0bc2\u0bae\u0bbf\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0ba9, \u0b95\u0bbe\u0bb2 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bc2\u0bae\u0bbf\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 (27\/59)<\/h3>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 27 (\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd)<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd 80-90% \u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 1-10 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0b95\u0bbe\u0bb2 \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0bae\u0bcb\u0b9a\u0bae\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b95\u0bc0\u0bb4\u0bcd \u0ba4\u0bbe\u0ba9\u0bbe\u0b95 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 59 (\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd)<\/strong> \u0b87\u0ba9\u0bcd\u0b9a\u0bc1\u0bb2\u0bc7\u0bb7\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b9a\u0bc7\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba8\u0bc0\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 110-120% \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 (86)<\/h3>\n<p><strong>\u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd 86 (\u0bb2\u0bbe\u0b95\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7)<\/strong> \u0b87\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd, \u0b95\u0bc8\u0baf\u0bbe\u0bb2\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0b87\u0ba4\u0bc1, \u0b92\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbe\u0bb3\u0bb0\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8, \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bc8 \u0b85\u0bb5\u0bc8 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<hr \/>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>ANSI \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd<\/th>\n<th>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0b99\u0bcd\u0b95\u0bc1<\/th>\n<th>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba3\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8<\/th>\n<th>\u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>50 \/ 51<\/td>\n<td>\u0ba8\u0bca\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb2\u0bae\u0bbf\u0b95\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1<\/td>\n<td>\u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bb5\u0bc1\u0b9f\u0bcd\u0baa\u0bc1\u0b9f\u0bcd\u0b9f\u0bc8 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 86 \u0bb2\u0bbe\u0b95\u0bcd\u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bb5\u0bc1\u0bae\u0bcd<\/td>\n<td>\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0-\u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b8a\u0b9a\u0bbf<\/td>\n<\/tr>\n<tr>\n<td>50N \/ 51N<\/td>\n<td>\u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0b9f\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf \u0bae\u0ba3\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1<\/td>\n<td>\u0ba8\u0bbf\u0bb2\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1, \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/td>\n<td>CT \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba8\u0bbf\u0bb2\u0bc8, \u0b8e\u0b9e\u0bcd\u0b9a\u0bbf\u0baf \u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bca\u0b95\u0bc8, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd NGR \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/td>\n<\/tr>\n<tr>\n<td>27 \/ 59<\/td>\n<td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/td>\n<td>\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8 \u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/td>\n<td>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b89\u0b9f\u0bcd\u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd, \u0ba4\u0bbe\u0bae\u0ba4 \u0ba8\u0bc7\u0bb0\u0bae\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1<\/td>\n<\/tr>\n<tr>\n<td>86<\/td>\n<td>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0ba4\u0bbe\u0ba9\u0bbe\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd<\/td>\n<td>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba8\u0bb0\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc8 \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/td>\n<td>\u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bc7\u0b9f\u0bcd\u0b9a\u0bcd, \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bcd\u0bb3\u0bcb\u0bb8\u0bcd-\u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3683\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03.webp\" alt=\"MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-03-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 2: MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n<p>\u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bb5\u0bc1\u0b9f\u0bcd\u0baa\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd, \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd\u0bb8\u0bcd, \u0bb2\u0bbe\u0b95\u0bcd\u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bc8 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0bb5\u0bb0\u0bc8\u0baf\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bb5\u0bc0\u0ba9 MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<h3>\u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baa\u0bcd \u0baa\u0baf\u0ba3 \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0bb5\u0bc1<\/h3>\n<p>\u0b8e\u0bb3\u0bbf\u0baf \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b9a\u0bb0\u0bcd\u0b95\u0bcd\u0baf\u0bc2\u0b9f\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba4\u0bc1 \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0ba9\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bb1\u0bc1\u0bae\u0bc2\u0b9f\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95 \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf \u0ba4\u0bc1\u0ba3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0bb2\u0bbe\u0b95\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>\u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 86 \u0bb2\u0bbe\u0b95\u0bcd\u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bb2 \u0ba8\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n<ul>\n<li>\u0b92\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/li>\n<li>\u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bca\u0b9f\u0bbf \u0b95\u0bbe\u0b9f\u0bcd\u0b9a\u0bbf<\/li>\n<li>\u0ba4\u0bbe\u0ba9\u0bbe\u0b95 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0ba4\u0b9f\u0bc8<\/li>\n<li>\u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0ba9 \u0b86\u0baa\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0b9f\u0bc8\u0bae\u0bc1\u0b95\u0bae\u0bcd<\/li>\n<\/ul>\n<h3>\u0baa\u0bb2\u0bcd\u0bb2\u0bbf\u0bb4\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b89\u0bb3\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/h3>\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd, \u0ba8\u0bbf\u0bb0\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0b95\u0bc7\u0b9f\u0bcd\u0bb8\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0bb5\u0bc1\u0b9f\u0bcd\u0baa\u0bc1\u0b9f\u0bcd \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95\u0bb5\u0bcb \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"wp-image-3684\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04.webp\" alt=\"MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/relay-trip-logic-map-for-mv-panels-50-51-50n-51n-27-59-86-how-they-inter-04-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><br \/>\n<\/figure>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 3: \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<p>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1, \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 (\u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 (\u0ba4\u0bb5\u0bb1\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bbe\u0bae\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd) \u0b86\u0b95\u0bbf\u0baf \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0baa\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>50\/51 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 50N\/51N \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b92\u0bb0\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/p>\n<p>2000A MV \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bc1\u0b9f\u0ba9\u0bcd 2000:5 CT-\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1:<br \/>\n\u2013 51 \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd: 1.2 \u00d7 FLA = 2400A (6A \u0b9a\u0bc6\u0b95\u0bcd\u0b95\u0ba3\u0bcd\u0b9f\u0bb0\u0bbf)<br \/>\n\u2013 51 \u0bae\u0bc1\u0bb1\u0bc8 \u0b9f\u0baf\u0bb2\u0bcd: \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0bb2\u0bcd 0.5<br \/>\n\u2013 50 \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd: 8 \u00d7 FLA = 16,000A (40A \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8)<br \/>\n\u2013 51N \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd: 0.5A \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 (200A \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, 10% CT \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1)<br \/>\n\u2013 51N \u0ba8\u0bc7\u0bb0\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bc8: \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd \u0bb5\u0bb3\u0bc8\u0bb5\u0bbf\u0bb2\u0bcd 0.3<br \/>\n\u2013 50N \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd: 2A \u0b9a\u0bc6\u0b95\u0bcd\u0b95\u0ba3\u0bcd\u0b9f\u0bb0\u0bbf (800A \u0baa\u0bbf\u0bb0\u0bc8\u0bae\u0bb0\u0bbf)<\/p>\n<p>\u0baa\u0bc2\u0bae\u0bbf\u0b9a\u0bcd \u0b9a\u0bc7\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0b9a\u0bc7\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd, \u0baa\u0bc2\u0bae\u0bbf\u0b9a\u0bcd \u0b9a\u0bc7\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0b9f\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba9, \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd \u0b85\u0bb5\u0bc8 \u0b9a\u0bae\u0bae\u0bbe\u0b95 \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9\u0bb5\u0bc8.<\/p>\n<h3>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0baf\u0bb2\u0bcd<\/h3>\n<p>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (27) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (59) \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bc8 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0b95\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (51V)<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0b88\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbf\u0b95\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b95\u0bc1\u0bb1\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bbe\u0ba4\u0ba9\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b9c\u0bc6\u0ba9\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0bb2\u0bbe\u0b95\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>86 \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0bc1, \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<br \/>\n\u2013 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0b95\u0bcd \u0b95\u0bbe\u0ba8\u0bcd\u0ba4\u0b9a\u0bcd\u0b9a\u0bc1\u0bb0\u0bc1\u0bb3\u0bcd (52a \u0baa\u0bbe\u0ba4\u0bc8)<br \/>\n\u2013 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0b95\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd (\u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd)<br \/>\n\u2013 \u0bae\u0bc2\u0b9f\u0bbf\u0baf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 (52Y)<br \/>\n\u2013 SCADA\/DCS \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8<br \/>\n\u2013 \u0b89\u0bb3\u0bcd\u0bb3\u0bc2\u0bb0\u0bcd \u0b85\u0bb1\u0bbf\u0bb5\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/p>\n<hr \/>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 4: \u0b95\u0bbe\u0bb2 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<p>\u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0b9f\u0bc8\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1, \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0bc8\u0baf \u0baa\u0ba3\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf (CTI) \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:<br \/>\n\u2013 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 MV \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 3-5 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd)<br \/>\n\u2013 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b93\u0bb5\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0bb5\u0bb2\u0bcd (\u0bae\u0bbf\u0ba9\u0bcd-\u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 2-4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd, \u0b8e\u0ba3\u0bcd\u0ba3\u0bbf\u0baf\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0baa\u0bc1\u0bb1\u0b95\u0bcd\u0b95\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1)<br \/>\n\u2013 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc1 (5-10 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bcd)<\/p>\n<p>\u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9\u0ba4\u0bc1 \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 0.2-0.4 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd CTI-\u0b90 \u0ba8\u0bbf\u0bb0\u0bcd\u0ba3\u0baf\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bc2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bae\u0bcd:<\/p>\n<p><strong>CTI = \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba8\u0bc7\u0bb0\u0bae\u0bcd + \u0bb0\u0bbf\u0bb2\u0bc7 \u0b93\u0bb5\u0bb0\u0bcd\u0b9f\u0bcd\u0bb0\u0bbe\u0bb5\u0bb2\u0bcd + \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bc1<\/strong><\/p>\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0b95\u0bb2\u0bb5\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1:<br \/>\nCTI = 0.08s + 0.00s + 0.12s = 0.20s \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd<\/p>\n<h3>\u0ba8\u0bca\u0b9f\u0bbf\u0baf\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>50 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bb5\u0bbe\u0bb2\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0ba9\u0bcd\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b85\u0ba4\u0bc1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bc6\u0ba9\u0bcd\u0bb1\u0bc7 \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bbf\u0ba9\u0bcd\u0bb1\u0bbf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b85\u0ba3\u0bc1\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<p><strong>\u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd (ZSI):<\/strong> \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bb3\u0bcd \u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bc8 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7, \u0baa\u0bc7\u0bb8\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bc6\u0bb1\u0bbe\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bbf\u0baf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 50-100ms) \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba8\u0bca\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b8e\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bbe\u0ba4\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0b9f \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 50-\u0b90 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 50 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<hr \/>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 5: \u0b95\u0bb3\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b8e\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0bae\u0bcd 1: \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0b86\u0bb2\u0bc8 13.8kV \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd<\/h3>\n<p>\u0b92\u0bb0\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0b86\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd 13.8kV \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd, 3000kVA \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bc8:<\/p>\n<p><strong>\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1:<\/strong><br \/>\n\u2013 51: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 125A, \u0bb5\u0bc6\u0bb0\u0bbf \u0b87\u0ba9\u0bcd\u0bb5\u0bb0\u0bcd\u0bb8\u0bcd, TD 3.0<br \/>\n\u2013 50: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 4000A (2\u00d7 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b87\u0ba9\u0bcd\u0bb0\u0bb7\u0bcd)<br \/>\n\u2013 51N: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 15A, \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bb2\u0bc8\u0b95\u0bc0\u0bb4\u0bcd, TD 2.0<br \/>\n\u2013 50N: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 200A<\/p>\n<p><strong>\u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1:<\/strong><br \/>\n\u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0bae\u0bcd 86T (\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0b99\u0bcd\u0b95\u0bbf \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1) \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bae\u0bcd, \u0b87\u0ba4\u0bc1 13.8kV \u0b8a\u0b9f\u0bcd\u0b9f\u0bae\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, 480V \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd. 27-\u0b86\u0bae\u0bcd \u0b95\u0bc2\u0bb1\u0bc1 (85%-\u0b87\u0bb2\u0bcd \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, 2.0 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf \u0ba4\u0bbe\u0bae\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd) \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba8\u0bbf\u0ba9\u0bcd\u0bb1\u0bc1\u0bb5\u0bbf\u0b9f\u0bbe\u0bae\u0bb2\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95, 480V \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bbf\u0bb0\u0ba4\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b89\u0ba4\u0bbe\u0bb0\u0ba3\u0bae\u0bcd 2: \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf \u0baa\u0bc7\u0bb8\u0bcd \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>\u0b92\u0bb0\u0bc1 34.5kV \u0baa\u0bb8\u0bcd \u0b9f\u0bc8 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd, \u0baa\u0bb8\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1:<\/p>\n<p><strong>\u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd:<\/strong><br \/>\n\u2013 \u0b83\u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd ZSI \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0b95\u0bb3\u0bc8 \u0baa\u0bb8\u0bcd \u0b9f\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<br \/>\n\u2013 \u0baa\u0bb8\u0bcd \u0b9f\u0bc8 51: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 2000A, \u0bb5\u0bc6\u0bb0\u0bbf \u0b87\u0ba9\u0bcd\u0bb5\u0bb0\u0bcd\u0bb8\u0bcd, \u0b9f\u0bbf\u0b9f\u0bbf 5.0<br \/>\n\u2013 \u0baa\u0bb8\u0bcd \u0b9f\u0bc8 50: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 8000A, ZSI \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd 100ms \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd<br \/>\n\u2013 \u0baa\u0bb8\u0bcd \u0b9f\u0bc8 50N: \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd 400A, ZSI \u0baa\u0bbf\u0bb3\u0bbe\u0b95\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd 100ms \u0ba4\u0bbe\u0bae\u0ba4\u0bae\u0bcd<\/p>\n<p>\u0baa\u0bc0\u0b9f\u0bb0\u0bbf\u0bb2\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0baa\u0bc0\u0b9f\u0bb0\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0bb3\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b92\u0bb0\u0bc1 \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8\u0baf\u0bc8 \u0b85\u0ba9\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bae\u0bbf\u0b95\u0bcd\u0b9e\u0bc8 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8 \u0b8e\u0ba9\u0bcd\u0bb1\u0bbe\u0bb2\u0bcd (\u0baa\u0bb8\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1), \u0baa\u0bb8\u0bcd \u0b9f\u0bc8 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 6: \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd, \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0ba4\u0bcd\u0ba4\u0baa\u0b9f\u0bbf \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0bc6\u0bb1\u0bbf\u0bae\u0bc1\u0bb1\u0bc8<\/h3>\n<ol>\n<li><strong>\u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc2\u0bb1\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0b95\u0bc2\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95, \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd\/\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0baa\u0baf\u0ba3\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b92\u0bb5\u0bcd\u0bb5\u0bca\u0bb0\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0ba9\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b95\u0bbe\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0bb0\u0bc8 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0b87\u0b9f\u0bc8\u0ba4\u0bcd\u0ba4\u0b9f\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8:<\/strong> ZSI \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95, \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n<li><strong>\u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1:<\/strong> 86 \u0b9a\u0bbe\u0ba4\u0ba9\u0bae\u0bcd \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd, \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n<h3>\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0b95\u0bb3 \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf, \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb2\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bc1:<\/p>\n<ul>\n<li><strong>CT \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0ba4\u0bc1\u0bb0\u0bc1\u0bb5\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bbe\u0bb2\u0bcd, \u0bae\u0ba3\u0bcd \u0baa\u0bbf\u0bb4\u0bc8 \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bbe\u0bae\u0bb2\u0bcd \u0baa\u0bcb\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/li>\n<li><strong>\u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8, \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd (\u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8)<\/li>\n<li><strong>\u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bcd:<\/strong> \u0ba4\u0bb5\u0bb1\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb0\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bbe\u0baf\u0bbf\u0bb2\u0bcd\u0b95\u0bb3\u0bcd, \u0ba4\u0bb5\u0bb1\u0bbe\u0ba9 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<\/ul>\n<hr \/>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 7: \u0ba8\u0bb5\u0bc0\u0ba9 \u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n<p>\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0bb2\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0b8e\u0ba3\u0bcd\u0ba9\u0bbf\u0b9a\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7 \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b89\u0bb3\u0bcd\u0bb3\u0b95 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0ba8\u0bbf\u0bb0\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/h3>\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0baf\u0ba9\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0b9a\u0bae\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<\/p>\n<pre><code>TRIP = (50 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 51 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 50N \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 51N \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 27 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 59) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bc8\n<\/code><\/pre>\n<p>\u0b87\u0b99\u0bcd\u0b95\u0bc1 BLOCK \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0bc0\u0b9f\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n<h3>\u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n<p>IEC 61850 GOOSE \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bbf\u0baf\u0bbf\u0b9f\u0bb2\u0bcd, \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bbe\u0ba4 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd\u0bb1\u0bbf \u0b85\u0ba4\u0bbf\u0bb5\u0bc7\u0b95 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba4\u0ba9\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0bb5\u0bc8:<\/p>\n<ul>\n<li>\u0b8a\u0b9f\u0bcd\u0b9f\u0bae\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0baa\u0bc7\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<li>\u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0 \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b87\u0b9f\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0baa\u0bcd \u0baa\u0baf\u0ba3\u0bae\u0bcd<\/li>\n<li>\u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n<\/ul>\n<h3>\u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/h3>\n<p>\u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b86\u0bb8\u0bbf\u0bb2\u0bcb\u0b95\u0bbf\u0bb0\u0bbe\u0baa\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b87\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0bb2\u0bbe\u0b9c\u0bbf\u0b95\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1, \u0b8f\u0ba4\u0bc7\u0ba9\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<h2>\u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bc1 8: \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb2\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h2>\n<p>\u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8 \u0b86\u0baf\u0bc1\u0bb3\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0baa\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0bb0\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bcd<\/h3>\n<p>NFPA 70B \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd:<\/p>\n<ul>\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0ba3\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0bb5\u0bb0\u0bc1\u0b9f\u0bbe\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8, \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1 \u0b85\u0bae\u0bc8\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n<li><strong>\u0ba4\u0bbf\u0b9f\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0b87\u0bb0\u0bc1 \u0bb5\u0bb0\u0bc1\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b92\u0bb0\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8<\/li>\n<li><strong>\u0b8e\u0ba3\u0bcd\u0ba9\u0bbf\u0b9a\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0b9a\u0bc1\u0baf\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 3-5 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n<h3>\u0b86\u0bb5\u0ba3\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd:<br \/>\n\u2013 \u0b85\u0b9a\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1<br \/>\n\u2013 \u0b95\u0b9f\u0bcd\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0baa\u0b9f\u0bbf \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<br \/>\n\u2013 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<br \/>\n\u2013 \u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc6\u0ba9\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bb0\u0bb2\u0bbe\u0bb1\u0bc1<br \/>\n\u2013 \u0b8e\u0ba8\u0bcd\u0ba4\u0bb5\u0bca\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/p>\n<hr \/>\n<h2>\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0b95\u0bc71: \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0ba8\u0bae\u0b95\u0bcd\u0b95\u0bc1 50 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 51 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b8f\u0ba9\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8?<\/h3>\n<p>50 (\u0ba8\u0bca\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bbe\u0ba9) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 51 (\u0b95\u0bbe\u0bb2\u0bae\u0bbf\u0b95\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f) \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0b86\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. 51 \u0b95\u0bc2\u0bb1\u0bc1, \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bbf\u0bb2\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bc1\u0ba4\u0bb2\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 50 \u0b95\u0bc2\u0bb1\u0bc1, \u0bb0\u0bbf\u0bb2\u0bc7 \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0bb5\u0bc7\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0b99\u0bcd\u0b95\u0bc1 \u0b9a\u0bc7\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bbe\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1. \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9: \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd, \u0b85\u0bb0\u0bc1\u0b95\u0bbf\u0bb2\u0bc1\u0bb3\u0bcd\u0bb3 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b95\u0bc72: 86 \u0bb2\u0bbe\u0b95\u0bcd\u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b95\u0bbe\u0ba3\u0bcd\u0b9f\u0bbe\u0b95\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/h3>\n<p>\u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8f\u0ba4\u0bc7\u0ba9\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 86 \u0bb2\u0bbe\u0b95\u0bcd\u0b85\u0bb5\u0bc1\u0b9f\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd: (1) \u0baa\u0bb2 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b92\u0bb0\u0bc7 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0b85\u0bb1\u0bbf\u0b95\u0bc1\u0bb1\u0bbf \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, (2) \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bb2\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, (3) \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bb4\u0bc1\u0ba4\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0b92\u0bb0\u0bc1 \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0ba9 \u0b86\u0baa\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b87\u0b9f\u0bc8\u0bae\u0bc1\u0b95\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 (4) \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bc1 \u0b92\u0bb0\u0bc1 \u0bae\u0bc1\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0b95\u0bcd \u0b95\u0bb5\u0bb2\u0bc8\u0baf\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b8e\u0bb3\u0bbf\u0baf, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bc73: \u0bb0\u0bbf\u0bb2\u0bc7 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8 (CTI) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/h3>\n<p>\u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 CTI, \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1. \u0ba8\u0bb5\u0bc0\u0ba9 \u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, 0.20-0.25 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9\u0ba4\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0bae\u0bbf\u0ba9\u0bcd\u0baeeccanical \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0bb0\u0bbf\u0bb2\u0bc7\u0bb5\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0baf\u0ba3\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1 0.30-0.40 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bae\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bc6\u0bb0\u0bbf\u0baf \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd. CTI-\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bb2 \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bc1 \u0b9a\u0bc7\u0bb0\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0baa\u0bbf\u0bb4\u0bc8\u0ba4\u0bcd \u0ba4\u0bb1\u0bcd\u0baa\u0bcb\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0b95\u0bc74: \u0bae\u0ba3\u0bcd\u0b9f\u0bb2\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b87\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd (ZSI) \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/h3>\n<p>\u0b87\u0bb2\u0bcd\u0bb2\u0bc8. ZSI \u0b95\u0bbe\u0bb2 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc8 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0ba4\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bbf\u0bb2\u0bcd\u0bb2\u0bc8. ZSI \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0baf\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. ZSI-\u0b90 \u0b92\u0bb0\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0bbe\u0b9f\u0bbe\u0b95\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b87\u0ba4\u0bc1 \u0baa\u0bc7\u0bb8\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bb5\u0bc7\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b85\u0ba9\u0bc1\u0bae\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 ZSI \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bc7\u0baf\u0bc7 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0b95\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0baa\u0bbf\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0baa\u0bbf\u0bb4\u0bc8 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 ZSI-\u0b90\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0b95\u0bc75: \u0bb0\u0bc6\u0b9a\u0bbf\u0bb8\u0bcd\u0b9f\u0ba9\u0bcd\u0bb8\u0bcd-\u0b95\u0bbf\u0bb0\u0bb5\u0bc1\u0ba3\u0bcd\u0b9f\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd 50N\/51N \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0bc1?<\/h3>\n<p>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1-\u0ba8\u0bbf\u0bb2\u0bae\u0bbf\u0bb1\u0b95\u0bcd\u0b95 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba8\u0bbf\u0bb2\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd \u0ba8\u0b9f\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8 \u0ba8\u0bbf\u0bb2\u0bae\u0bbf\u0bb1\u0b95\u0bcd\u0b95 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bbe\u0bb2\u0bcd (NGR) \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b89\u0baf\u0bb0\u0bcd-\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0ba3\u0bb0\u0bcd\u0ba4\u0bbf\u0bb1\u0ba9\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b9a\u0bc1\u0bae\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba4\u0bbf\u0bb0\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bb5\u0bc1\u0bae\u0bcd, NGR \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd 10-25% \u0b87\u0bb2\u0bcd 51N \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0ba8\u0bbf\u0bb2\u0b95\u0bcd \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 50-80% \u0b87\u0bb2\u0bcd 50N \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0bc8 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b95\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0baa\u0bc2\u0bae\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0b9f \u0ba8\u0bc7\u0bb0 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b85\u0ba9\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1 \u0baa\u0bc2\u0bae\u0bbf\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc1\u0bae\u0bcd \u0b87\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0bae\u0bb2\u0bcd \u0b92\u0bb0\u0bc7 \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bbf\u0bb2\u0bcd \u0baa\u0bb2 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 51N \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0ba9\u0bcd\u0ba9\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0bc76: \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 (27) \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0baa\u0baf\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bcd?<\/h3>\n<p>\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd: (1) \u0bae\u0bcb\u0b9f\u0bcd\u0b9f\u0bbe\u0bb0\u0bcd \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b8f\u0bb1\u0bcd\u0bb1 \u0b87\u0bb1\u0b95\u0bcd\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, (2) \u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0bbf\u0b95 \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, (3) \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 VT \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1, (4) \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9f\u0bc7\u0baa\u0bcd \u0b9a\u0bc7\u0b9e\u0bcd\u0b9a\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd (5) \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc0\u0bb4\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 VT \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbe\u0bae\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd. \u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9 \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 2-5 \u0bb5\u0bbf\u0ba9\u0bbe\u0b9f\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bb0\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd \u0ba4\u0bbe\u0bae\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 80-85% \u0baa\u0bc6\u0baf\u0bb0\u0bb3\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0b85\u0b9f\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n<h3>\u0b95\u0bc77: \u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd, \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 86 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0b95\u0bc8\u0baf\u0bbe\u0bb3\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9?<\/h3>\n<p>\u0b8e\u0ba3\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd, \u0bb0\u0bbf\u0bb2\u0bc7 HMI \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0b95\u0bb5\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b87\u0b9f\u0bc8\u0bae\u0bc1\u0b95\u0bae\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b92\u0bb0\u0bc1 \u0baa\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0b89\u0bb3\u0bcd\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bcd. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 86 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc7 \u0bb5\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0b85\u0bb5\u0bc8: (1) \u0baa\u0bbf\u0bb0\u0bc7\u0b95\u0bcd\u0b95\u0bb0\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc8 \u0b95\u0b9f\u0bbf\u0ba9\u0bae\u0bbe\u0b95 \u0b87\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1, (2) \u0bb0\u0bbf\u0bb2\u0bc7 \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1, \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bca\u0b9f\u0bbf\u0b95\u0bb3\u0bcd, (3) \u0b86\u0baa\u0bb0\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bbf\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bbe\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0bc8\u0bae\u0bc1\u0bb1\u0bc8 \u0bae\u0bc0\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd (4) \u0bb0\u0bbf\u0bb2\u0bc7 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0b95\u0bcd \u0b95\u0bbf\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc1\u0ba4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0baa\u0bb2 \u0bb5\u0b9a\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9: \u0bae\u0bc1\u0ba4\u0bb2\u0bcd-\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0b89\u0bb3\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0bb0\u0ba4\u0bbf \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bc1\u0bb1\u0bc8 \u0b87\u0ba3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0b95 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 86 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>\n<hr \/>\n<h2>\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8: \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<p>MV \u0baa\u0bc7\u0ba9\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bb0\u0bbf\u0bb2\u0bc7 \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0baa\u0bb2 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bc1:<\/p>\n<ol>\n<li><strong>\u0b85\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0bb5\u0bc7\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd\u0ba3\u0bae\u0bcd \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0baf, \u0b89\u0b9f\u0ba9\u0b9f\u0bbf (50\/50N) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb2 \u0ba4\u0bbe\u0bae\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f (51\/51N) \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bc8 \u0b87\u0ba3\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1:<\/strong> \u0bae\u0bc7\u0bb2\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0b95\u0bc0\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0b85\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9a\u0bbe\u0ba4\u0ba9\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bbe\u0ba9 \u0ba8\u0bc7\u0bb0 \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bc7\u0ba3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n<li><strong>\u0bae\u0bc8\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd:<\/strong> \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0b95\u0bcd\u0b95, \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0bc1\u0ba4\u0bbf\u0baf\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b95\u0bcb\u0bb3\u0bbe\u0bb1\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0ba4\u0bbe\u0ba9\u0bbf\u0baf\u0b99\u0bcd\u0b95\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc2\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95, \u0baa\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0bb0\u0bbf\u0bb2\u0bc7\u0b95\u0bcd\u0b95\u0bb3\u0bc8 (86) \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/li>\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bcb\u0b9f\u0bcd\u0b9f \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95, \u0b95\u0bc1\u0bb1\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (27) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bcd (59) \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1:<\/strong> \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0ba3\u0bc8\u0baf\u0bbf\u0b9f\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0906\u0935\u0927\u093f\u0915\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba3 \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95 \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/li>\n<li><strong>\u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd:<\/strong> \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0ba4\u0bb0\u0bb5\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0bb5\u0baf\u0bb0\u0bbf\u0b99\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb0\u0bbf\u0bb2\u0bc7 \u0b9f\u0bbf\u0bb0\u0bbf\u0baa\u0bcd \u0ba4\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bae\u0bcd (relay trip logic) \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bc0\u0b9f\u0bc1, \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0ba3\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0baa\u0bb2\u0ba9\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9f\u0bbf\u0b9c\u0bbf\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa\u0bae\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bbf \u0bb5\u0bb0\u0bc1\u0bb5\u0ba4\u0bbe\u0bb2\u0bcd, \u0b92\u0bb0\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bcb\u0b9f\u0bca\u0ba9\u0bcd\u0bb1\u0bc1 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b87\u0ba9\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0baf\u0bbe\u0ba4\u0bb5\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<hr \/>\n<p><em>\u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0b95\u0bc2\u0b9f\u0bc1\u0ba4\u0bb2\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95, IEEE \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0b95\u0bcd\u0ba4\u0bbf \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bb0\u0bbf\u0bb2\u0bc7 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb4\u0bc1 (PSRCC) \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0bbf\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bc8 \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bae\u0bcd \u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: <a href=\"https:\/\/www.pes-psrc.org\/\" target=\"_blank\" rel=\"noopener\">IEEE PES \u0baa\u0bbf\u0b8e\u0bb8\u0bcd\u0b86\u0bb0\u0bcd\u0b9a\u0bbf\u0b9a\u0bbf<\/a>.<\/em><\/p>\n<hr \/>\n<h2>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<ul>\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-contactor\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbf \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc7\u0bb2\u0bcb\u0b9f\u0bcd\u0b9f\u0bae\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0ba4\u0bca\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bc1<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/power-distribution-transformers\/\">\u0bae\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/\">\u0b9a\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9a\u0bcd \u0b95\u0bbf\u0baf\u0bb0\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd \u0b95\u0bc2\u0bb1\u0bc1\u0b95\u0bb3\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/switchgear-parts\/contact-box\/\">\u0b8e\u0baa\u0bcb\u0b95\u0bcd\u0b9a\u0bbf \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0baa\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/99635\" target=\"_blank\" rel=\"noopener\">IEC 62271-100 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A Comprehensive Technical Guide to Protective Relay Coordination and Interlocking Schemes Introduction In medium voltage (MV) electrical distribution systems, protective relays serve as the critical first line of defense against electrical faults, equipment damage, and personnel hazards. Understanding how these relays interlock and communicate through trip logic maps is fundamental to designing, commissioning, and maintaining [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":3680,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[27],"tags":[],"class_list":["post-3685","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-switchgear-parts-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=3685"}],"version-history":[{"count":7,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3685\/revisions"}],"predecessor-version":[{"id":3818,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3685\/revisions\/3818"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/3680"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=3685"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=3685"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=3685"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}