{"id":3709,"date":"2026-05-04T09:00:00","date_gmt":"2026-05-04T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=3709"},"modified":"2026-05-31T05:59:22","modified_gmt":"2026-05-31T05:59:22","slug":"moisture-transformer-oil-paper-ppm-relative-saturation-dry-out","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/moisture-transformer-oil-paper-ppm-relative-saturation-dry-out\/","title":{"rendered":"\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0baf\u0ba9\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd: ppm \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1"},"content":{"rendered":"<h2>\u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0bae\u0bcd: \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bcc\u0ba9 \u0ba8\u0bbe\u0b9a\u0b95\u0ba9\u0bcd<\/h2>\n<p>\u0ba8\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb0 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0baa\u0bb0\u0bb5\u0bb2\u0bbe\u0ba9 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb4\u0bbf\u0bb5\u0bc1\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0bae\u0bbe\u0b9a\u0bc2\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b86\u0b95\u0bc1\u0bae\u0bcd. \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba4\u0bc1\u0bb1\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 18 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bbe\u0b95 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1, \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0b95\u0bb3\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0baf\u0bbf\u0b9f\u0bcd\u0b9f \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bc1 \u0b8e\u0bb5\u0bcd\u0bb5\u0bbe\u0bb1\u0bc1 \u0baa\u0bc7\u0bb0\u0bb4\u0bbf\u0bb5\u0bc1\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0ba8\u0bc7\u0bb0\u0bbf\u0bb2\u0bcd \u0b95\u0ba3\u0bcd\u0b9f\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0bc7\u0ba9\u0bcd\u2014\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbe\u0ba9 \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0ba9\u0bcd\u0b95\u0bc2\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc7 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0bb3\u0bbf\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1 \u0b86\u0b95\u0bbf\u0baf \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0ba4\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1, \u0ba4\u0bbe\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd (\u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bbf\u0bb0\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bcd) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bb2\u0bcb\u0bb8\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0bae\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b92\u0bb0\u0bc1\u0b99\u0bcd\u0b95\u0bbf\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4 \u0b89\u0bb1\u0bb5\u0bc8\u0b9a\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1. \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bb0\u0bbf\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b85\u0ba4\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b89\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0b95\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0bb3\u0bbf \u0b87\u0b9f\u0bc8\u0bb5\u0bc6\u0bb3\u0bbf\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b87\u0ba8\u0bcd\u0ba4 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc7 \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1: \u0b85\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0baa\u0bcd \u0baa\u0bb4\u0bc8\u0bae\u0bc8\u0baf\u0bbe\u0ba4\u0bb2\u0bcd \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bb2\u0bcd\u0bb5\u0bbf \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb7\u0baf\u0bae\u0bcd \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bb2\u0bcd\u0bb2\u2014\u0b85\u0ba4\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bb0\u0bb5\u0bc1\u0b9a\u0bc6\u0bb2\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bca\u0ba4\u0bcd\u0ba4\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0bb0\u0bc8, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd, \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0b8e\u0bb4\u0bc1\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe\u0ba9 \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0b85\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bb3\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature.webp\" alt=\"\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0bc0\u0bb0\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8\u0baa\u0b9f\u0bae\u0bcd, \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 RS% \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bcd 18 ppm \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1.\" class=\"wp-image-3705\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-oil-saturation-curve-temperature-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0ba4\u0bbe\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc6\u0b99\u0bcd\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0b95 \u0b89\u0baf\u0bb0\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b87\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1, \u0b92\u0bb0\u0bc7 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 ppm \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n<h2>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0ba4\u0bb2\u0bcd: ppm \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1<\/h2>\n<h3>\u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0b95\u0bc8\u0b95\u0bb3\u0bcd (ppm): \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/h3>\n<p>\u0b8e\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bcd \u0baa\u0bbe\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bcd (ppm \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbf.\u0b95\u0bbf\/\u0b95\u0bbf.\u0b95\u0bbf) \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bb0\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1\u0bb3\u0bcd\u0bb3 \u0ba8\u0bc0\u0bb0\u0bbf\u0ba9\u0bcd \u0bae\u0bc1\u0bb4\u0bc1 \u0b85\u0bb3\u0bb5\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. ASTM D1533-\u0b87\u0ba9\u0bcd\u0baa\u0b9f\u0bbf \u0b92\u0bb0\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0baf\u0bcd\u0bb5\u0b95 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0bbe\u0bb0\u0bcd\u0bb2\u0bcd \u0b83\u0baa\u0bbf\u0bb7\u0bb0\u0bcd \u0b9f\u0bc8\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc7\u0bb7\u0ba9\u0bcd, \u0bae\u0bc6\u0ba4\u0bcd\u0ba4\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bb0\u0bc8\u0b9a\u0bb2\u0bbf\u0bb2\u0bcd \u0ba8\u0bc0\u0bb0\u0bc8 \u0b85\u0baf\u0bcb\u0b9f\u0bc0\u0ba9\u0bc1\u0b9f\u0ba9\u0bcd \u0bb5\u0bbf\u0ba9\u0bc8\u0baa\u0bc1\u0bb0\u0bbf\u0baf\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b87\u0ba4\u0bc8 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p>\u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0ba4\u0ba3\u0bcd\u0ba3\u0bc0\u0bb0\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc2\u0bb1\u0bbf\u0ba9\u0bbe\u0bb2\u0bc1\u0bae\u0bcd, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b92\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f \u0b85\u0ba4\u0ba9\u0bcd \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bb1\u0bcd\u0bb1\u0bbf \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbe\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0ba8\u0bc0\u0bb0\u0bbf\u0bb2\u0bcd \u0b95\u0bb0\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<p><strong>25\u00b0C \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bb5\u0b95\u0bc8 \u0bb5\u0bbe\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0b95\u0bcd \u0b95\u0bb0\u0bc8\u0ba4\u0bbf\u0bb1\u0ba9\u0bcd:<\/strong><br \/>\n\u2013 \u0ba4\u0bbe\u0ba4\u0bc1 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd: \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 55-65 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd<br \/>\n\u2013 \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd (FR3): \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 1,100+ ppm<br \/>\n\u2013 \u0b9a\u0bc6\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd: \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd\u0baa\u0bcb\u0ba4\u0bc1 2,700+ \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd<\/p>\n<p>\u0bae\u0bbf\u0ba9\u0bb0\u0bb2\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0bb2\u0bcd 35 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bcb\u0bb0\u0bbe\u0baf\u0bae\u0bbe\u0b95 60% \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0b92\u0bb0\u0bc1 \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0bbe\u0ba9 \u0b95\u0bb5\u0bb2\u0bc8. \u0b85\u0ba4\u0bc7 35 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bc1 \u0ba4\u0bcb\u0bb0\u0bbe\u0baf\u0bae\u0bbe\u0b95 3% \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0bae\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b89\u0bb1\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bbe\u0bae\u0bb2\u0bcd, \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bbe\u0ba9 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba4\u0ba9\u0bcd\u0ba9\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0baf\u0bbe\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 (RS%): \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/h3>\n<p>\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1, \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0bae\u0bbe\u0b95 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0b9a\u0ba4\u0bb5\u0bc0\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1 \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf\u0ba4\u0bc1:<\/p>\n<ul>\n<li><strong>\u0b87\u0bb2\u0bb5\u0b9a \u0ba8\u0bc0\u0bb0\u0bcd \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0ba4\u0bb2\u0bcd \u0b85\u0baa\u0bbe\u0baf\u0bae\u0bcd<\/strong>100% RS-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd, \u0ba8\u0bc0\u0bb0\u0bcd \u0b95\u0bb0\u0bc8\u0ba4\u0bbf\u0bb1\u0ba9\u0bb1\u0bcd\u0bb1\u0ba4\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<li><strong>\u0b87\u0bb0\u0bc1\u0bae\u0bc1\u0ba9\u0bc8\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bbf\u0bb5\u0bc1 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0ba4\u0b95\u0bb5\u0bc1<\/strong>: 30% RS-\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc7\u0bb2\u0bcd \u0baa\u0ba9\u0bcd\u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n<li><strong>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b87\u0b9f\u0bae\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0bb5\u0bc1 \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8<\/strong>\u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bc7 \u0ba8\u0bc0\u0bb0\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba4\u0bbf\u0b9a\u0bc8\u0baf\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bae\u0bbe\u0ba9\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<\/ul>\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0ba3\u0bb0\u0bbf\u0b95\u0bb3\u0bcd \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8\u0baf\u0bbf\u0baf\u0bb2\u0bcd \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0ba8\u0bc7\u0bb0\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. RS%-\u0b90 ppm \u0b86\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1 \u0bb5\u0bb3\u0bc8\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b85\u0bb1\u0bbf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd (%)<\/th>\n<th>\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/th>\n<th>\u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>&lt; 1.0%<\/td>\n<td>\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 (\u0baa\u0bc1\u0ba4\u0bbf\u0baf\/\u0b89\u0bb2\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4)<\/td>\n<td>\u0bae\u0bc1\u0bb4\u0bc1 \u0bb5\u0b9f\u0bbf\u0bb5\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0baf\u0bc1\u0bb3\u0bcd<\/td>\n<\/tr>\n<tr>\n<td>1.0 \u2013 2.0%<\/td>\n<td>\u0ba8\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1<\/td>\n<td>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/td>\n<\/tr>\n<tr>\n<td>2.0 \u2013 3.0%<\/td>\n<td>\u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9<\/td>\n<td>2-4\u00d7 \u0bae\u0bc1\u0ba4\u0bbf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0bae\u0bc1\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/td>\n<\/tr>\n<tr>\n<td>3.0 \u2013 4.0%<\/td>\n<td>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9<\/td>\n<td>5-10\u00d7 \u0bae\u0bc1\u0ba4\u0bc1\u0bae\u0bc8\u0baf\u0b9f\u0bc8\u0ba4\u0bb2\u0bcd \u0ba4\u0bc1\u0bb0\u0bbf\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/td>\n<\/tr>\n<tr>\n<td>4.0%<\/td>\n<td>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9<\/td>\n<td>\u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bb2\u0bc8\u0baf\u0bc0\u0b9f\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0ba4\u0bbe\u0bb3\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bb1\u0bc8\u0bae\u0bc1\u0b95 \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8, \u0b8f\u0ba9\u0bc6\u0ba9\u0bbf\u0bb2\u0bcd \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc2\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd. \u0b85\u0bb1\u0bbf\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8 (DFR) \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0ba3\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1, \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<h3>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b87\u0b9f\u0baa\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf \u0b87\u0baf\u0b95\u0bcd\u0b95\u0bb5\u0bbf\u0baf\u0bb2\u0bcd<\/h3>\n<p>\u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b85\u0ba4\u0bbf\u0b95\u0baa\u0b9f\u0bcd\u0b9a \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b9a\u0bc2\u0b9f\u0bbe\u0ba9 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc1\u0bae\u0bc8 \u0b95\u0bbe\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bbf\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b87\u0b9f\u0baa\u0bcd\u0baa\u0bc6\u0baf\u0bb0\u0bcd\u0bb5\u0bc1 \u0b95\u0bbe\u0bb2\u0baa\u0bcd\u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p>\u0b9a\u0bc0\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd\u0bb5\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0bb5\u0b95\u0bc8 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0bb5\u0bbf\u0ba4\u0bae\u0bbe\u0b95 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b9a\u0bbf\u0bb2\u0bbf\u0b95\u0bcd\u0b95\u0bbe \u0b9c\u0bc6\u0bb2\u0bcd \u0baa\u0bbf\u0bb0\u0bc0\u0ba4\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b95\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd\u0bb5\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bb5\u0bb3\u0bbf\u0bae\u0ba3\u0bcd\u0b9f\u0bb2 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0ba4\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bb5\u0ba9\u0bae\u0bbe\u0ba9 \u0b9c\u0bc6\u0bb2\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0bae\u0bc2\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b9a\u0bc0\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bc7 \u0ba8\u0bc1\u0bb4\u0bc8\u0bb5\u0ba4\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bb4\u0bc8\u0bae\u0bc8\u0baf\u0b9f\u0bc8\u0bb5\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b8e\u0ba8\u0bcd\u0ba4\u0bb5\u0bca\u0bb0\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart.webp\" alt=\"\u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0b85\u0bb2\u0bc8\u0bb5\u0bb0\u0bbf\u0b9a\u0bc8 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0bae\u0bc2\u0b9f\u0bcd\u0b9f\u0bb2\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0bcd\u0b9f \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\" class=\"wp-image-3707\" width=\"1200\" height=\"675\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-300x169.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-1024x576.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-768x432.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-dry-out-methods-comparison-chart-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0ba9\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0bae\u0bcd, \u0b95\u0bbf\u0b9f\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bbe\u0bb2\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0ba4\u0bb3 \u0b89\u0bb3\u0bcd\u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1; \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0bae\u0bbf\u0b95 \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0bb2\u0bc8 \u0b85\u0b9f\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b85\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0baa\u0b9f\u0bcd\u0b9f\u0bb1\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/figcaption><\/figure>\n<h2>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd: \u0b92\u0bb0\u0bc1 \u0ba8\u0b9f\u0bc8\u0bae\u0bc1\u0bb1\u0bc8\u0b9a\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1<\/h2>\n<h3>\u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0ba4\u0bb2\u0bcd<\/h3>\n<p>\u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd 10 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd 0.5%-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0baf\u0ba4\u0bbe\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bae\u0bcd \u0baa\u0bc6\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbe\u0bb2\u0bc1\u0bae\u0bcd \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0ba3\u0bbf\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0ba4\u0bbf \u0b85\u0b9f\u0bcd\u0b9f\u0bb5\u0ba3\u0bc8\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc1\u0bb0\u0bbf\u0bae\u0bc8 \u0b85\u0bb3\u0bbf\u0ba4\u0bcd\u0ba4 \u0bb5\u0bc6\u0bb3\u0bbf\u0ba8\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0b9f\u0bae\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 25 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0baf\u0bc2\u0ba9\u0bbf\u0b9f\u0bcd\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0ba9\u0bcd \u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0bc1\u0bb3\u0bcd\u0bb3\u0bc7\u0ba9\u0bcd. \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0bae\u0bcd \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bb5\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba4\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b95\u0bc1\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0bb4\u0bbf\u0b95\u0bb3\u0bc8 \u0ba8\u0bbe\u0bae\u0bcd \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p>\u0b9a\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0baa\u0bb2 \u0bae\u0bc2\u0bb2\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9:<br \/>\n\u2013 \u0bb5\u0bb3\u0bbf\u0bae\u0ba3\u0bcd\u0b9f\u0bb2 \u0b9a\u0bc1\u0bb5\u0bbe\u0b9a\u0bae\u0bcd (\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0bb3\u0bb0\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd)<br \/>\n\u2013 \u0b95\u0bc7\u0bb8\u0bcd\u0b95\u0bc6\u0b9f\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc0\u0bb2\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1<br \/>\n\u2013 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bb2\u0bcb\u0bb8\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc1 (\u0b92\u0bb0\u0bc1 \u0ba4\u0bc1\u0ba3\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbe\u0b95 \u0ba8\u0bc0\u0bb0\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1)<br \/>\n\u2013 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b86\u0b95\u0bcd\u0b9a\u0bbf\u0b9c\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0b9f\u0bcd\u0b95\u0bb3\u0bcd<\/p>\n<h3>\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/h3>\n<p>\u0b86\u0baf\u0bcd\u0bb5\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 20-25\u00b0C) \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bc1, \u0b87\u0ba4\u0bc1 \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b95\u0ba3\u0bbf\u0b9a\u0bae\u0bbe\u0b95 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bb2\u0bbe\u0bae\u0bcd. \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1, \u0baa\u0bca\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0b99\u0bcd\u0b95\u0bbf\u0bb2\u0bbf\u0baa\u0bcd \u0baa\u0b9f\u0bbf\u0bb5\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bc6\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0b9a\u0bc1\u0bae\u0bc8-\u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0bae\u0bbe\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0ba3\u0bcd\u0b9f\u0bc1, \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b85\u0bb2\u0bbe\u0bb0\u0bae\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bc8 \u0b85\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd. \u0b9a\u0bae\u0bae\u0bbe\u0ba9 \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba9\u0bcd, 65\u00b0C \u0b9a\u0bb0\u0bbe\u0b9a\u0bb0\u0bbf \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0bb0\u0bc1 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd, 80\u00b0C \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0baf\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b92\u0ba9\u0bcd\u0bb1\u0bc8 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 ppm-\u0b90\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0baa\u0bb2 \u0ba8\u0bcb\u0baf\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bc8 \u0b87\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/h3>\n<p>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1 \u0b92\u0bb0\u0bc7 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1. \u0b85\u0ba9\u0bc1\u0baa\u0bb5\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0bb5\u0bcb\u0bb0\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bcb\u0ba3 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9\u0bb0\u0bcd:<\/p>\n<ol>\n<li><strong>\u0b95\u0bbe\u0bb0\u0bcd\u0bb2\u0bcd \u0b83\u0baa\u0bbf\u0bb7\u0bb0\u0bcd \u0b9f\u0bc8\u0b9f\u0bcd\u0b9f\u0bbf\u0bb0\u0bc7\u0bb7\u0ba9\u0bcd<\/strong>: \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0bae\u0bc1\u0bb4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd<\/li>\n<li><strong>\u0b87\u0bb0\u0bc1\u0bae\u0bc1\u0ba9\u0bc8\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bcd (DFR)<\/strong>: \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/li>\n<li><strong>\u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd RS% \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd<\/strong>\u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1<\/li>\n<li><strong>\u0b95\u0bb0\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1<\/strong>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n<li><strong>\u0bae\u0bbf\u0ba9\u0bcd \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bbf\/\u0bb5\u0bc0\u0b95\u0bcd\u0b95 \u0b95\u0bbe\u0bb0\u0ba3\u0bbf<\/strong>: \u0b89\u0baf\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9<\/li>\n<\/ol>\n<p>\u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0b9f\u0bc8\u0baf\u0bc7\u0baf\u0bbe\u0ba9 \u0b95\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0bbe\u0b9f\u0bc1, \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0baa\u0bcd \u0baa\u0bbf\u0bb4\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bcb \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0b9a\u0bbe\u0ba4\u0bbe\u0bb0\u0ba3 \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bc8\u0baf\u0bcb \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<hr \/>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart.webp\" alt=\"\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b9a\u0ba4\u0bb5\u0bc0\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\" class=\"wp-image-3708\" width=\"1200\" height=\"900\" srcset=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart.webp 1200w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-300x225.webp 300w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-1024x768.webp 1024w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-768x576.webp 768w, https:\/\/xbrele.com\/wp-content\/uploads\/2026\/04\/transformer-moisture-specification-acceptance-flowchart-16x12.webp 16w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">\u0b92\u0bb0\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1 \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bbe\u0ba9 \u0b8f\u0bb1\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0bb5\u0bbf\u0bb5\u0bb0\u0bae\u0bcd, RS% \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0ba9 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf, \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0ba8\u0bcd\u0ba4\u0bc8\u0baf \u0b92\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bb1\u0bcd\u0bb1 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/figcaption><\/figure>\n<h2>\u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd: \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1<\/h2>\n<h3>\u0bb5\u0bc6\u0baa\u0bcd\u0baa \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf<\/h3>\n<p>\u0b9a\u0bc2\u0b9f\u0bbe\u0ba9 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0bbf\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b8a\u0b9f\u0bc1\u0bb0\u0bc1\u0bb5\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd. \u0b87\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bb5\u0bc8:<\/p>\n<ol>\n<li>\u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd \u0baa\u0bbf\u0bb0\u0bbf\u0bb5\u0bbf\u0bb2\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8 70-80\u00b0C \u0bb5\u0bb0\u0bc8 \u0b9a\u0bc2\u0b9f\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bb2\u0bcd<\/li>\n<li>\u0bae\u0ba3\u0bbf\u0b95\u0bcd\u0b95\u0bc1 10-15% \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf \u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb3\u0bb5\u0bc1 \u0b8e\u0ba9\u0bcd\u0bb1 \u0bb5\u0bbf\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b89\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf<\/li>\n<li>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bb5\u0bbe\u0baf\u0bc1\u0ba8\u0bc0\u0b95\u0bcd\u0b95 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc2\u0bb2\u0b95\u0bcd\u0b95\u0bc2\u0bb1\u0bc1 \u0bb5\u0b9f\u0bbf\u0b95\u0b9f\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bcd\u0bb5\u0ba4\u0bc1<\/li>\n<li>\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb2\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf \u0b85\u0bb3\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/li>\n<\/ol>\n<p><strong>\u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0bb1\u0bc1\u0ba4\u0bbf<\/strong>: \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 10 ppm-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc7 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd (\u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 2-4 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 0.5-1.0% \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bc7\u0bb1\u0bcd\u0bb1\u0bae\u0bcd)<\/p>\n<p><strong>\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>: \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd 3%-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba4\u0bae\u0bbe\u0ba9 \u0b85\u0bb3\u0bb5\u0bc1 \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0b9f\u0bcd\u0b9f \u0b85\u0bb2\u0b95\u0bc1\u0b95\u0bb3\u0bcd<\/p>\n<p><strong>\u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bb3\u0bcd<\/strong>: \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b88\u0bb0\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b95\u0bc8\u0baf\u0bbe\u0bb3 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1; \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bc7\u0bb0\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0bae\u0bc1\u0b9f\u0b95\u0bcd\u0b95\u0bbf\u0bb5\u0bbf\u0b9f\u0bc1\u0bae\u0bcd<\/p>\n<h3>\u0b95\u0bbe\u0baf\u0bcd\u0b9a\u0bcd\u0b9a\u0bb2\u0bcd \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/h3>\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba8\u0bc0\u0bb0\u0bbf\u0ba9\u0bcd \u0b95\u0bca\u0ba4\u0bbf\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0baa\u0bcd\u0baa\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0bb5\u0b95\u0bc8\u0b95\u0bb3\u0bcd \u0b89\u0bb3\u0bcd\u0bb3\u0ba9:<\/p>\n<p><strong>\u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd<\/strong> \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0ba9\u0bcd\u0b9a\u0bb0\u0bcd\u0bb5\u0bc7\u0b9f\u0bcd\u0b9f\u0bb0\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba8\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0baa\u0bbf\u0bb3\u0bbe\u0b99\u0bcd\u0b95\u0bc6\u0b9f\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0bae\u0bc0\u0ba4\u0bc1 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bc8 (0.5-5 \u0b9f\u0bbe\u0bb0\u0bcd) \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0ba4\u0bc1\u0ba3\u0bcd\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8 \u0baa\u0bca\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/p>\n<p><strong>\u0bae\u0bc1\u0bb4\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0b9a\u0bcd \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8<\/strong> \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b86\u0bb1\u0bcd\u0bb1\u0bb2\u0bcd \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b86\u0bb4\u0bae\u0bbe\u0ba9 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd (&lt; 1 torr), \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb1\u0bae\u0bbe\u0b95 \u0b9a\u0bc2\u0b9f\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 1.0% \u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc0\u0bb4\u0bc7 \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b86\u0bb5\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/h3>\n<p>\u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbf\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b85\u0b95\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0b99\u0bcd\u0b95\u0ba4\u0bcd \u0ba4\u0bb0\u0bae\u0bbe\u0b95 \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf \u0ba8\u0bbf\u0bb2\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b95\u0bb0\u0bc1\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8:<\/p>\n<ol>\n<li>\u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0b95\u0bca\u0ba4\u0bbf\u0ba8\u0bbf\u0bb2\u0bc8 \u0b95\u0bca\u0ba3\u0bcd\u0b9f \u0b95\u0bc6\u0bb0\u0bcb\u0b9a\u0bbf\u0ba9\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bc1 \u0baa\u0bcb\u0ba9\u0bcd\u0bb1 \u0b95\u0bb0\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bc8 \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf \u0bb5\u0b9f\u0bbf\u0bb5\u0bbf\u0bb2\u0bcd \u0b85\u0bb1\u0bbf\u0bae\u0bc1\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<li>\u0b86\u0bb5\u0bbf \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4 \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bb2\u0bcb\u0bb8\u0bcd \u0baa\u0bb0\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0ba4\u0bbf\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0b95\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b9a\u0bc2\u0b9f\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<li>\u0ba8\u0bc0\u0bb0\u0bcd \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bbf\u0ba9\u0bc1\u0bb3\u0bcd \u0b86\u0bb5\u0bbf\u0baf\u0bbe\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/li>\n<li>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f\u0bae\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bbf\u0b95\u0bcd\u0b95 \u0ba8\u0bc0\u0bb0\u0bbe\u0bb5\u0bbf\u0baf\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1<\/li>\n<li>\u0b87\u0bb2\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd.<\/li>\n<\/ol>\n<p>\u0b87\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0bb1\u0bc8, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 0.5%-\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95 \u0b85\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1, \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bc8 \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b87\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b9a\u0bbf\u0bb1\u0baa\u0bcd\u0baa\u0bc1 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0b87\u0ba4\u0bc1 \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 \u0bae\u0bb1\u0bc1\u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0b87\u0ba3\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0ba3\u0bbf\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b89\u0bb2\u0bb0\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b89\u0b9f\u0bcd\u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd<\/h3>\n<p>\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b89\u0bb2\u0bb0\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0b89\u0b9f\u0bcd\u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd \u0bae\u0bc6\u0ba4\u0bc1\u0bb5\u0bbe\u0ba9 \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3 \u0b92\u0bb0\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0bb5\u0bb4\u0bbf\u0baf\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bb0\u0bc1\u0bb5\u0bbf-\u0ba4\u0bb0 \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 (\u0baa\u0ba9\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf &lt; -40\u00b0C), \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bc1\u0bae\u0bbf\u0bb4\u0bcd\u0b95\u0bb3\u0bbe\u0b95\u0baa\u0bcd \u0baa\u0bbe\u0baf\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb1\u0bbf\u0b9e\u0bcd\u0b9a\u0bbf, \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd \u0ba4\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0baa\u0bbf\u0bb0\u0ba4\u0bcd\u0baf\u0bc7\u0b95\u0b95\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0b9f\u0bc8\u0b95\u0bb3\u0bcd \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95 \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p><strong>\u0ba4\u0bbf\u0bb1\u0ba9\u0bc1\u0bb1\u0bc1\u0ba4\u0bbf<\/strong>: 4-8 \u0bb5\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0b85\u0b9f\u0bc8\u0b95\u0bbf\u0bb1\u0ba4\u0bc1; \u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 1.5-2.5%<\/p>\n<p><strong>\u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd<\/strong>: \u0ba4\u0bca\u0bb2\u0bc8\u0ba4\u0bc2\u0bb0 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4-\u0baa\u0b9f\u0bcd\u0b9c\u0bc6\u0b9f\u0bcd \u0b9a\u0bc2\u0bb4\u0bcd\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba4\u0bb2\u0bc8\u0baf\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b87\u0b9f\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0b95<\/p>\n<hr \/>\n<h2>\u0b8e\u0bb4\u0bc1\u0ba4\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd: \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd<\/h2>\n<h3>\u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0b8f\u0bb1\u0bcd\u0baa\u0bc1 \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bcd\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baf\u0bbe\u0ba9 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd:<\/p>\n<blockquote>\n<p>\u201cASTM D1533 \u0ba4\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0ba9\u0bcd\u0baa\u0b9f\u0bbf 20-25\u00b0C \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd 10 ppm-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1. \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bc0\u0b9f\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b8e\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bcd 0.5%-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbe\u0ba4\u0bc1. \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd 72 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd, \u0bae\u0bc7\u0bb2\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0baf\u0bc8 \u0b8e\u0b9f\u0bc1\u0baa\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0ba9\u0bb0\u0bcd, \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 24 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0bae\u0bbe\u0bb5\u0ba4\u0bc1 \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1\u0bb1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.\u201d<\/p>\n<\/blockquote>\n<p>\u0baa\u0bbf\u0bb1\u0bcd\u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bc8\u0b9a\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd: \u201c\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 \u0bae\u0bc0\u0bb1\u0bc1\u0bae\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0bbe\u0bb3\u0bb0\u0bbf\u0ba9\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0bb2\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb1\u0bcd\u0b9a\u0bbe\u0bb2\u0bc8 \u0bae\u0bc7\u0bb1\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0bb5\u0bc8\u0baf\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bc1 \u0b89\u0b9f\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.\u201d<\/p>\n<h3>\u0b9a\u0bc7\u0bb5\u0bc8\u0baa\u0bcd \u0baa\u0bb4\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95:<\/p>\n<blockquote>\n<p>\u201c\u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bbe\u0ba9\u0ba4\u0bc1, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 15 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 1.5%-\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0bb5\u0bbe\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd. \u0b92\u0baa\u0bcd\u0baa\u0ba8\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bbe\u0bb0\u0bb0\u0bcd, \u0b95\u0bbe\u0bb0\u0bcd\u0bb2\u0bcd \u0b83\u0baa\u0bbf\u0bb7\u0bb0\u0bcd \u0b9f\u0bc8\u0b9f\u0bcd\u0bb0\u0bc7\u0bb7\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bb1\u0bc1\u0baa\u0bcd\u0baa\u0bc1 \u0b85\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bc6\u0ba3\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0b89\u0bb3\u0bcd\u0bb3\u0bbf\u0b9f\u0bcd\u0b9f \u0bae\u0bc1\u0ba9\u0bcd\/\u0baa\u0bbf\u0ba9\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bb3\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b89\u0bb1\u0bc1\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95, \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0ba8\u0bcd\u0ba4 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd 48 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.\u201d<\/p>\n<\/blockquote>\n<h3>\u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/h3>\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0b95\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1:<\/p>\n<blockquote>\n<p>\u201c\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0ba3\u0bb0\u0bbf\u0b95\u0bb3\u0bcd 0-100\u00b0C \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u00b13\u00b0C RS \u0ba4\u0bc1\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc8 \u0b85\u0bb3\u0bb5\u0bbf\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b89\u0ba3\u0bb0\u0bbf\u0b95\u0bb3\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba9\u0bbe\u0b95\u0bb5\u0bc7 \u0b88\u0b9f\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0ba4\u0bc1, \u0bae\u0bcb\u0b9f\u0bcd\u0baa\u0bb8\u0bcd RTU \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 IEC 61850 \u0bb5\u0bb4\u0bbf\u0baf\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0b9a\u0bc1\u0bae\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0baa\u0bcb\u0ba4\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95, \u0b95\u0bbe\u0bb2-\u0ba4\u0bbe\u0bae\u0ba4 \u0bb5\u0b9f\u0bbf\u0b95\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bc1\u0b9f\u0ba9\u0bcd 20% RS (\u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd 30% RS (\u0b85\u0baa\u0bbe\u0baf\u0b95\u0bb0\u0bae\u0bbe\u0ba9) \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb2\u0bcd \u0b8e\u0b9a\u0bcd\u0b9a\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bc1\u0bb3\u0bcd\u0bb3\u0bbf\u0b95\u0bb3\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bae\u0bc8\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.\u201d<\/p>\n<\/blockquote>\n<hr \/>\n<h2>\u0b95\u0bb3\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bcd: \u0ba8\u0bbf\u0b9c \u0b89\u0bb2\u0b95 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0baa\u0bbe\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1: \u0ba4\u0bb5\u0bb1\u0bbe\u0b95 \u0bb5\u0bb4\u0bbf\u0ba8\u0b9f\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u201c\u0ba8\u0bb2\u0bcd\u0bb2\u201d \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1<\/h3>\n<p>\u0bb5\u0b9a\u0ba8\u0bcd\u0ba4 \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 25 MVA \u0ba4\u0bc1\u0ba3\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0bb2\u0bcd 28 ppm \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1\u2014\u0b87\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd 35 ppm \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1. \u0b85\u0ba8\u0bcd\u0ba4 \u0b87\u0bb2\u0bc8\u0baf\u0bc1\u0ba4\u0bbf\u0bb0\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd, \u0ba8\u0bc0\u0ba3\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0bb5\u0bc6\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bcd-\u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd (cold-start) \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bcd \u0ba4\u0bcb\u0bb2\u0bcd\u0bb5\u0bbf\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bb4\u0bbf\u0bb5\u0b95\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1. \u0baa\u0bbf\u0ba9\u0bcd-\u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0baf\u0ba4\u0bc1:<\/p>\n<ul>\n<li>\u0bb5\u0b9a\u0ba8\u0bcd\u0ba4\u0b95\u0bbe\u0bb2 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 45\u00b0C \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd (\u0b9a\u0bc1\u0bae\u0bc8 \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf) \u0ba8\u0b9f\u0bc8\u0baa\u0bc6\u0bb1\u0bcd\u0bb1\u0ba4\u0bc1.<\/li>\n<li>\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 38% \u0b86\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1\u2014\u0b95\u0bb5\u0ba9\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bb0\u0bbf\u0baf \u0b8e\u0bb2\u0bcd\u0bb2\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0ba8\u0ba9\u0bcd\u0bb1\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1.<\/li>\n<li>30 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbe\u0bb2 \u0b9a\u0bc7\u0bb5\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd 3.8%-\u0b90 \u0b8e\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0ba4\u0bc1.<\/li>\n<li>\u0b95\u0bc1\u0bb3\u0bbf\u0bb0\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 5\u00b0C \u0b86\u0b95\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0bc1, \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bc8\u0ba4\u0bcd \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf\u0ba4\u0bc1.<\/li>\n<\/ul>\n<p>\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1, \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd \u0b87\u0bb2\u0bcd\u0bb2\u0bbe\u0bae\u0bb2\u0bcd \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 ppm-\u0b90 \u0bae\u0b9f\u0bcd\u0b9f\u0bc1\u0bae\u0bc7 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bbe\u0bb2\u0bcd, \u0b89\u0ba3\u0bcd\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8\u0ba4\u0bcd \u0ba4\u0bb5\u0bb1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1.<\/p>\n<h3>\u0bb5\u0bb4\u0b95\u0bcd\u0b95\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1: \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb0\u0bae\u0bbe\u0ba9 \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2 \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0bc1<\/h3>\n<p>\u0b92\u0bb0\u0bc1 \u0b89\u0bb1\u0bcd\u0baa\u0ba4\u0bcd\u0ba4\u0bbf \u0b86\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 1985-\u0b86\u0bae\u0bcd \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0ba4\u0baf\u0bbe\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 10 MVA \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bbf\u0bb2\u0bcd 52 ppm \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b95\u0bbe\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1, \u0b87\u0ba4\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd 3.2% \u0b8e\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1. \u0b89\u0b9f\u0ba9\u0b9f\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0b85\u0ba8\u0bcd\u0ba4 \u0b86\u0bb2\u0bc8 \u0baa\u0bbf\u0ba9\u0bcd\u0bb5\u0bb0\u0bc1\u0bb5\u0ba9\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0ba8\u0bcd\u0ba4\u0bc6\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1:<\/p>\n<ol>\n<li>\u0bae\u0bc2\u0ba9\u0bcd\u0bb1\u0bc1 \u0bb5\u0bbe\u0bb0 \u0bb5\u0bc6\u0ba8\u0bcd\u0ba8\u0bc0\u0bb0\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf (12 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b85\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4\u0ba4\u0bc1)<\/li>\n<li>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd \u0b89\u0bb2\u0bb0\u0bcd \u0b95\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0ba4\u0bb2\u0bcd (\u0ba8\u0bbe\u0ba9\u0bcd\u0b95\u0bc1 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bcd)<\/li>\n<li>\u0b8e\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b9a\u0bbf\u0bb2\u0bbf\u0b95\u0bcd\u0b95\u0bbe\u0ba9\u0bcd \u0bb0\u0baa\u0bcd\u0baa\u0bb0\u0bcd \u0b95\u0bc7\u0bb8\u0bcd\u0b95\u0b9f\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<li>\u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0ba3\u0bb0\u0bbf \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb2\u0bcd<\/li>\n<\/ol>\n<p>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd DFR \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1, \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 2.1% \u0b8e\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bcd\u0b9f\u0ba4\u0bc1. \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b9a\u0bcd \u0b9a\u0bc6\u0bb2\u0bb5\u0bbf\u0ba9\u0bcd \u0b92\u0bb0\u0bc1 \u0b9a\u0bbf\u0bb1\u0bc1 \u0baa\u0b95\u0bc1\u0ba4\u0bbf\u0baf\u0bbf\u0bb2\u0bc7\u0baf\u0bc7, \u0ba4\u0bbf\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f 10 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1 \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b86\u0baf\u0bc1\u0b9f\u0bcd\u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb0\u0bc1\u0bae\u0bcd\u0baa\u0bbf\u0baf\u0ba4\u0bc1.<\/p>\n<hr \/>\n<h2>\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n<h3>\u0b8e\u0ba8\u0bcd\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc1 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0ba8\u0b9f\u0bb5\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8?<\/h3>\n<p>\u0bae\u0bbf\u0ba9\u0bb0\u0bb2\u0bcd \u0b86\u0baf\u0bbf\u0bb2\u0bcd \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd, 35 ppm-\u0b90 (25\u00b0C \u0b85\u0bb3\u0bb5\u0bc1\u0b95\u0bcb\u0bb2\u0bbf\u0bb2\u0bcd) \u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b87\u0baf\u0b95\u0bcd\u0b95 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbf\u0bb2\u0bcd 40%-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b89\u0b9f\u0ba9\u0b9f\u0bbf \u0bb5\u0bbf\u0b9a\u0bbe\u0bb0\u0ba3\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bcb\u0bb0\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 3.5%-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd, 6-12 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0b9f\u0bcd\u0b9f\u0bae\u0bbf\u0b9f\u0bb2\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0ba4\u0bc1\u0bb0\u0bbf\u0ba4\u0bae\u0b9f\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bc1\u0ba4\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. 50%-\u0b90 \u0bb5\u0bbf\u0b9f \u0b85\u0ba4\u0bbf\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b95\u0ba3\u0bcd\u0ba3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0ba4\u0bcd \u0ba4\u0bc6\u0bb0\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0b9f\u0bc8\u0baf\u0bb1\u0bcd\u0bb1 \u0ba8\u0bc0\u0bb0\u0bcd \u0b92\u0bb0\u0bc1 \u0b85\u0bb5\u0b9a\u0bb0\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bbe\u0b95\u0bc1\u0bae\u0bcd\u2014\u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bb5\u0bb0\u0bc8 \u0b9a\u0bc1\u0bae\u0bc8\u0baf\u0bc8\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bc8\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/h3>\n<p>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bcd (\u0bae\u0bb0\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0bae\u0ba9\u0bc8 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd, \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0b9a\u0bcd\u0b9a\u0bbf\u0baf\u0bbe\u0ba9 \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0b9a\u0bc1\u0bae\u0bc8\u0b95\u0bb3\u0bcd) \u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd \u0b95\u0ba3\u0bcd\u0b95\u0bbe\u0ba3\u0bbf\u0baa\u0bcd\u0baa\u0bc8\u0baa\u0bcd \u0baa\u0bc6\u0bb1 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bb1\u0bcd\u0bb1\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4\u0baa\u0b9f\u0bcd\u0b9a\u0bae\u0bcd \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bcb\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0bae\u0bbe\u0ba4\u0bbf\u0bb0\u0bbf\u0b95\u0bb3\u0bcd \u0b8e\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95\u0bae\u0bcd, \u0b95\u0bc7\u0bb8\u0bcd\u0b95\u0bc6\u0b9f\u0bcd \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0ba4\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b89\u0bb3\u0bcd \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 30 \u0ba8\u0bbe\u0b9f\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0bb3\u0bcd \u0b9a\u0bcb\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd. \u0baa\u0bc1\u0ba4\u0bbf\u0baf \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bae\u0bcd \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0b9f\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0b95 6 \u0bae\u0bbe\u0ba4\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0bbf\u0bb1\u0b95\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0b95\u0b9a\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0ba8\u0bcd\u0ba4 \u0b92\u0bb0\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb0\u0bc1\u0bb5\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0bc8 \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0ba9\u0bcd \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0b9a\u0bc6\u0baf\u0bcd\u0baf \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bc1\u0bae\u0bbe?<\/h3>\n<p>\u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b8f\u0bb1\u0bcd\u0b95\u0ba9\u0bb5\u0bc7 \u0ba8\u0bbf\u0b95\u0bb4\u0bcd\u0ba8\u0bcd\u0ba4\u0bc1\u0bb5\u0bbf\u0b9f\u0bcd\u0b9f \u0b9a\u0bc6\u0bb2\u0bcd\u0bb2\u0bc1\u0bb2\u0bcb\u0bb8\u0bcd \u0b9a\u0bbf\u0ba4\u0bc8\u0bb5\u0bc8 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bae\u0bc8\u0b95\u0bcd\u0b95 \u0bae\u0bc1\u0b9f\u0bbf\u0baf\u0bbe\u0ba4\u0bc1. \u0baa\u0bb2 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bbe\u0bb2 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bbe\u0ba9 \u0bae\u0bc1\u0ba4\u0bc1\u0bae\u0bc8\u0baf\u0b9f\u0bc8\u0ba4\u0bb2\u0bbe\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0b87\u0baf\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bb5\u0bbf\u0baf\u0bb2\u0bcd \u0bb5\u0bb2\u0bbf\u0bae\u0bc8\u0baf\u0bc8 \u0b87\u0bb4\u0ba8\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bbe\u0bb2\u0bcd, \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0ba8\u0bc0\u0b95\u0bcd\u0b95\u0bc1\u0bb5\u0ba4\u0bc1 \u0bae\u0bc0\u0ba4\u0bae\u0bc1\u0bb3\u0bcd\u0bb3 \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1, \u0b86\u0ba9\u0bbe\u0bb2\u0bcd \u0b87\u0bb4\u0ba8\u0bcd\u0ba4\u0ba4\u0bc8 \u0bae\u0bc0\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bc6\u0bb4\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0ba4\u0bc1. \u0b83\u0baa\u0bbf\u0baf\u0bc2\u0bb0\u0bbe\u0ba9\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bc1 \u0bae\u0bc2\u0bb2\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0baa\u0bbe\u0bb2\u0bbf\u0bae\u0bb0\u0bc8\u0b9a\u0bc7\u0bb7\u0ba9\u0bcd \u0baa\u0b9f\u0bcd\u0b9f\u0bae\u0bcd (DP) \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8, \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bb5\u0ba4\u0bc1 \u0baa\u0baf\u0ba9\u0bc1\u0bb3\u0bcd\u0bb3\u0ba4\u0bbe \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bc1 \u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbe\u0ba4\u0bbe\u0bb0 \u0bb0\u0bc0\u0ba4\u0bbf\u0baf\u0bbe\u0b95 \u0b9a\u0bbf\u0bb1\u0ba8\u0bcd\u0ba4\u0ba4\u0bbe \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0b89\u0ba4\u0bb5\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bb0\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1\u0baa\u0bcd \u0baa\u0b95\u0bc1\u0baa\u0bcd\u0baa\u0bbe\u0baf\u0bcd\u0bb5\u0bbf\u0bb1\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0b8e\u0ba9\u0bcd\u0ba9?<\/h3>\n<p>\u0b85\u0ba4\u0bbf\u0b95 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0baa\u0bb4\u0bc8\u0bae\u0bc8\u0baf\u0b9f\u0bc8\u0ba4\u0bb2\u0bc8 \u0bb5\u0bbf\u0bb0\u0bc8\u0bb5\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf, \u0b95\u0bbe\u0bb0\u0bcd\u0baa\u0ba9\u0bcd \u0b9f\u0bc8 \u0b86\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0bcd\u0baa\u0ba9\u0bcd \u0bae\u0bcb\u0ba9\u0bbe\u0b95\u0bcd\u0b9a\u0bc8\u0b9f\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bc1\u0bb1\u0bc8\u0ba8\u0bcd\u0ba4 \u0bae\u0bbf\u0ba9\u0bcd\u0ba9\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4 \u0b85\u0bb4\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0baa\u0b95\u0bc1\u0ba4\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baf\u0bc7\u0bb1\u0bcd\u0bb1\u0b9a\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bc2\u0ba3\u0bcd\u0b9f\u0bbf, \u0bb9\u0bc8\u0b9f\u0bcd\u0bb0\u0b9c\u0ba9\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbf\u0bb2 \u0b9a\u0bae\u0baf\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0b9a\u0bbf\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bc0\u0ba9\u0bc8 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b95\u0bb0\u0bc8\u0ba8\u0bcd\u0ba4 \u0bb5\u0bbe\u0baf\u0bc1\u0baa\u0bcd \u0baa\u0bcb\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bb3\u0bc8 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0bb5\u0bb0\u0bb2\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1 \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0b9a\u0bc6\u0baf\u0bcd\u0bb5\u0ba4\u0bc1, \u0bae\u0bb1\u0bcd\u0bb1\u0baa\u0b9f\u0bbf \u0bae\u0bb0\u0bcd\u0bae\u0bae\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bcb\u0ba9\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbe\u0baf\u0bc1 \u0b89\u0bb0\u0bc1\u0bb5\u0bbe\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bc8 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0bb0\u0ba3-\u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1 \u0b89\u0bb1\u0bb5\u0bc1\u0b95\u0bb3\u0bc8 \u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0bb5\u0bc6\u0bb3\u0bbf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<h3>\u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0baf\u0bbe?<\/h3>\n<p>\u0ba8\u0bbf\u0b9a\u0bcd\u0b9a\u0baf\u0bae\u0bbe\u0b95. \u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0bb5\u0bb1\u0bcd\u0bb1\u0bbf\u0ba9\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd \u0b95\u0bbe\u0bb0\u0ba3\u0bae\u0bbe\u0b95, \u0bae\u0bbf\u0b95 \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bc1\u0bb4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 (\u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bcd \u0baa\u0bca\u0ba4\u0bc1\u0bb5\u0bbe\u0b95 200-400 \u0baa\u0bbf\u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd) \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bbf\u0baf\u0bb5\u0bc8. \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0ba9\u0bc1\u0bae\u0bcd, \u0b95\u0bbe\u0b95\u0bbf\u0ba4 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8 \u0bb5\u0bc7\u0bb1\u0bc1\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1\u2014\u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0bb2\u0bbf\u0bb0\u0bc1\u0ba8\u0bcd\u0ba4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0bbf\u0b95\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0bbf\u0bb1\u0bae\u0bcd\u0baa\u0b9f \u0b88\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9, \u0b87\u0ba4\u0bc1 \u0baa\u0bc1\u0ba4\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0bbe\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0bae\u0bc7\u0bae\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0b95\u0bcd\u0b95\u0bc2\u0b9f\u0bc1\u0bae\u0bcd. \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1 \u0ba4\u0bbf\u0bb0\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bbe\u0b95 \u0bae\u0bc1\u0bb4\u0bc1 \u0baa\u0bbf\u0baa\u0bbf\u0b8e\u0bae\u0bcd-\u0b90\u0b95\u0bcd \u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb2\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8 (&lt; 25% RS) \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bb5\u0bc1\u0bae\u0bcd.<\/p>\n<h3>\u0b86\u0ba9\u0bcd\u0bb2\u0bc8\u0ba9\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b89\u0ba3\u0bb0\u0bbf\u0b95\u0bb3\u0bcd \u0b8e\u0bb5\u0bcd\u0bb5\u0bb3\u0bb5\u0bc1 \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9\u0bb5\u0bc8?<\/h3>\n<p>\u0ba8\u0bb5\u0bc0\u0ba9 \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0bc7\u0b95\u0bcd\u0b95 \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd\u0b95\u0bb3\u0bcd, \u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0b95 \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0b95\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd\u0baa\u0bcb\u0ba4\u0bc1, \u0ba8\u0bae\u0bcd\u0baa\u0b95\u0bae\u0bbe\u0ba9 \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0b9a\u0bc6\u0bb1\u0bbf\u0bb5\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bcd\u0b9f\u0bc8 \u0bb5\u0bb4\u0b99\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9. \u0b86\u0baf\u0bcd\u0bb5\u0b95 \u0b95\u0bbe\u0bb0\u0bcd\u0bb2\u0bcd \u0b83\u0baa\u0bbf\u0bb7\u0bb0\u0bcd \u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0ba4\u0bcb\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0ba4\u0bc1, \u0b85\u0bb3\u0bb5\u0bc1 \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc8 \u0b89\u0bb1\u0bc1\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bbf\u0ba9\u0bcd \u0b87\u0bb0\u0bc1\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bae\u0bcd \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bcd\u2014\u0ba8\u0bbf\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0b9f\u0bc8\u0baf\u0bbe\u0ba4 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc8\u0baf\u0bbf\u0bb2\u0bcd, \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0ba4\u0bca\u0b9f\u0bcd\u0b9f\u0bbf\u0baf\u0bbf\u0bb2\u0bcd \u0ba8\u0bbf\u0bb1\u0bc1\u0bb5\u0bb5\u0bc1\u0bae\u0bcd, \u0ba4\u0bc7\u0b99\u0bcd\u0b95\u0bbf\u0baf \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b87\u0b9f\u0b99\u0bcd\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b85\u0bb2\u0bcd\u0bb2. \u0ba8\u0bbf\u0bb2\u0bc8\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1 \u0b8f\u0bb1\u0bcd\u0baa\u0b9f\u0bcd\u0b9f\u0bc1 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1 \u0bae\u0bc1\u0ba9\u0bcd\u0baa\u0bc1, \u0b9a\u0bc6\u0ba9\u0bcd\u0b9a\u0bbe\u0bb0\u0bcd 5-7 \u0b86\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd \u0b8e\u0ba9 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb2\u0bbe\u0bae\u0bcd.<\/p>\n<h3>\u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0b9a\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b8e\u0ba9\u0bcd\u0ba9\u0bc6\u0ba9\u0bcd\u0ba9 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0b87\u0ba3\u0bc8\u0ba4\u0bcd\u0ba4\u0bbf\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd?<\/h3>\n<p>\u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd: \u0b86\u0bb0\u0bae\u0bcd\u0baa \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd (\u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd ppm, \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0bae\u0bcd %), \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0bae\u0bc1\u0bb1\u0bc8 \u0b85\u0bb3\u0bb5\u0bc1\u0bb0\u0bc1 \u0baa\u0ba4\u0bbf\u0bb5\u0bc1 (\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0b95\u0bb3\u0bcd, \u0b95\u0bbe\u0bb2\u0bae\u0bcd), 48 \u0bae\u0ba3\u0bbf \u0ba8\u0bc7\u0bb0 \u0ba8\u0bbf\u0bb2\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb2\u0bcd \u0b95\u0bbe\u0bb2\u0ba4\u0bcd\u0ba4\u0bc1\u0b9f\u0ba9\u0bcd \u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bcd, \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0ba4\u0bb0\u0bae\u0bcd \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1 (\u0b87\u0bb0\u0bc1\u0bae\u0bc1\u0ba9\u0bc8\u0baf \u0bae\u0bbf\u0ba9\u0bcd\u0ba4\u0b9f\u0bc8 \u0bb5\u0bb2\u0bbf\u0bae\u0bc8, \u0b85\u0bae\u0bbf\u0bb2\u0ba4\u0bcd\u0ba4\u0ba9\u0bcd\u0bae\u0bc8, \u0b87\u0b9f\u0bc8\u0bae\u0bc1\u0b95 \u0b87\u0bb4\u0bc1\u0bb5\u0bbf\u0b9a\u0bc8), \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bbe\u0b95\u0bcd\u0b95 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bcd, \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf (transformer) \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bbf \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bc1\u0bae\u0bcd \u0b85\u0bb2\u0bcd\u0bb2\u0ba4\u0bc1 \u0b85\u0ba4\u0bc8\u0bb5\u0bbf\u0b9f \u0bae\u0bc7\u0bb2\u0bbe\u0ba9 \u0b9a\u0bc1\u0ba4\u0bcd\u0ba4\u0bae\u0bbe\u0ba9 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bc1\u0b95\u0bbf\u0ba9\u0bcd\u0bb1\u0ba9 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bb1\u0bcd\u0b95\u0bbe\u0ba9 \u0b9a\u0bbe\u0ba9\u0bcd\u0bb1\u0bbf\u0ba4\u0bb4\u0bcd.<\/p>\n<hr \/>\n<h2>\u0bae\u0bc1\u0b9f\u0bbf\u0bb5\u0bc1\u0bb0\u0bc8: \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf \u0b85\u0bae\u0bcd\u0b9a\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<p>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bca\u0b9f\u0bcd\u0b9f\u0bbf \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd\u0baa\u0bca\u0bb0\u0bc1\u0bb3\u0bbf\u0bb2\u0bcd \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bae\u0bc7\u0bb2\u0bbe\u0ba3\u0bcd\u0bae\u0bc8 \u0b8e\u0ba9\u0bcd\u0baa\u0ba4\u0bc1, \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bae\u0bcd (ppm) \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bc6\u0baf\u0bb2\u0bcd\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bcd \u0ba4\u0bbf\u0bb1\u0ba9\u0bcd (\u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1) \u0b86\u0b95\u0bbf\u0baf \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc8\u0baf\u0bc1\u0bae\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bc8 \u0b85\u0bb5\u0b9a\u0bbf\u0baf\u0bae\u0bbe\u0b95\u0bcd\u0b95\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4 \u0b87\u0bb0\u0ba3\u0bcd\u0b9f\u0bc1 \u0b85\u0bb3\u0bb5\u0bc0\u0b9f\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b8e\u0ba4\u0bc1\u0bb5\u0bc1\u0bae\u0bcd \u0ba4\u0ba9\u0bbf\u0baf\u0bbe\u0b95 \u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0b95\u0ba4\u0bc8\u0baf\u0bc8\u0b9a\u0bcd \u0b9a\u0bca\u0bb2\u0bcd\u0bb2\u0bbe\u0ba4\u0bc1\u2014\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0bb5\u0bbf\u0bb3\u0b95\u0bcd\u0b95\u0ba4\u0bcd\u0ba4\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8\u0b9a\u0bcd \u0b9a\u0bc2\u0bb4\u0bb2\u0bcd, \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8 \u0baa\u0bb1\u0bcd\u0bb1\u0bbf\u0baf \u0bb5\u0bbf\u0bb4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0ba3\u0bb0\u0bcd\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0baa\u0bbf\u0bb1 \u0b95\u0ba3\u0bcd\u0b9f\u0bb1\u0bbf\u0baf\u0bc1\u0bae\u0bcd \u0ba4\u0bb0\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bbe\u0ba9 \u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1 \u0ba4\u0bc7\u0bb5\u0bc8\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/p>\n<p>\u0ba8\u0bbf\u0ba9\u0bc8\u0bb5\u0bbf\u0bb2\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0bb3 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bbf\u0baf \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bcd:<\/p>\n<ol>\n<li><strong>\u0bae\u0bc1\u0bb4\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 ppm-\u0b90 \u0bb5\u0bbf\u0b9f \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1 \u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0bae\u0bbe\u0ba9\u0ba4\u0bc1.<\/strong> \u0b87\u0bb0\u0bc1\u0baa\u0b95\u0bc1\u0bb2 \u0b86\u0baa\u0ba4\u0bcd\u0ba4\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0bb5\u0ba4\u0bb1\u0bcd\u0b95\u0bc1<\/li>\n<li><strong>\u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0bae\u0bcd 1,000-3,000 \u0bae\u0b9f\u0b99\u0bcd\u0b95\u0bc1 \u0b85\u0ba4\u0bbf\u0b95 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8\u0ba4\u0bcd \u0ba4\u0b95\u0bcd\u0b95\u0bb5\u0bc8\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong> \u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bc1\u0bb3\u0bcd\u0bb3 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bc8 \u0bb5\u0bbf\u0b9f\u2014\u0b8e\u0baa\u0bcd\u0baa\u0bcb\u0ba4\u0bc1\u0bae\u0bcd \u0b95\u0bbe\u0b95\u0bbf\u0ba4\u0ba4\u0bcd\u0ba4\u0bbf\u0ba9\u0bcd \u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0b9f\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<li><strong>\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b9a\u0bae\u0ba8\u0bbf\u0bb2\u0bc8\u0baf\u0bc8 \u0bb5\u0bbf\u0baf\u0ba4\u0bcd\u0ba4\u0b95\u0bc1 \u0bae\u0bc1\u0bb1\u0bc8\u0baf\u0bbf\u0bb2\u0bcd \u0baa\u0bbe\u0ba4\u0bbf\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1.<\/strong>\u2014\u0b9a\u0bc0\u0bb0\u0bbe\u0ba9, \u0b86\u0bb5\u0ba3\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0ba8\u0bbf\u0bb2\u0bc8\u0bae\u0bc8\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0bb5\u0bc1\u0bae\u0bcd<\/li>\n<li><strong>\u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0ba4\u0bbf\u0bb0\u0bb5\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb5\u0bcd\u0bb5\u0bc7\u0bb1\u0bc1 \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8.<\/strong>\u2014\u0b87\u0baf\u0bb1\u0bcd\u0b95\u0bc8 \u0b8e\u0bb8\u0bcd\u0b9f\u0bb0\u0bcd\u0b95\u0bb3\u0bcd \u0b85\u0ba4\u0bbf\u0b95 \u0bae\u0bc1\u0bb4\u0bc1 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0ba4\u0bcd\u0ba4\u0bc8 \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bbe\u0b95\u0ba4\u0bcd \u0ba4\u0bbe\u0b99\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/li>\n<li><strong>\u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0ba4\u0bcd \u0ba4\u0bc7\u0bb0\u0bcd\u0bb5\u0bc1, \u0ba4\u0bc0\u0bb5\u0bbf\u0bb0\u0ba4\u0bcd\u0ba4\u0bc8\u0baa\u0bcd \u0baa\u0bca\u0bb1\u0bc1\u0ba4\u0bcd\u0ba4\u0ba4\u0bc1.<\/strong>\u2014\u0bb2\u0bc7\u0b9a\u0bbe\u0ba9 \u0baa\u0bbe\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1 \u0b9a\u0bc2\u0b9f\u0bbe\u0ba9 \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0b9a\u0bc1\u0bb4\u0bb1\u0bcd\u0b9a\u0bbf, \u0b95\u0b9f\u0bc1\u0bae\u0bc8\u0baf\u0bbe\u0ba9 \u0bae\u0bbe\u0b9a\u0bc1\u0baa\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u0bb1\u0bcd\u0b95\u0bc1 \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0b9a\u0bbf\u0b95\u0bbf\u0b9a\u0bcd\u0b9a\u0bc8<\/li>\n<li><strong>\u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0ba4\u0bc6\u0bb3\u0bbf\u0bb5\u0bbe\u0b95 \u0b87\u0bb0\u0bc1\u0b95\u0bcd\u0b95 \u0bb5\u0bc7\u0ba3\u0bcd\u0b9f\u0bc1\u0bae\u0bcd.<\/strong>\u2014\u0bb5\u0bc6\u0baa\u0bcd\u0baa\u0ba8\u0bbf\u0bb2\u0bc8 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd, \u0b9a\u0bb0\u0bbf\u0baa\u0bbe\u0bb0\u0bcd\u0baa\u0bcd\u0baa\u0bc1\u0ba4\u0bcd \u0ba4\u0bc7\u0bb5\u0bc8\u0b95\u0bb3\u0bcd, \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b87\u0ba3\u0b95\u0bcd\u0b95 \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bc1\u0b95\u0bb3\u0bcd \u0b86\u0b95\u0bbf\u0baf\u0bb5\u0bb1\u0bcd\u0bb1\u0bc8 \u0b89\u0bb3\u0bcd\u0bb3\u0b9f\u0b95\u0bcd\u0b95\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/li>\n<\/ol>\n<p>\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b95\u0bbe\u0baa\u0bcd\u0baa\u0bc1 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0bb4\u0bbf\u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0ba4\u0bcd\u0ba4 \u0bb5\u0bbf\u0bb0\u0bbf\u0bb5\u0bbe\u0ba9 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bc1\u0ba4\u0bb2\u0bc1\u0b95\u0bcd\u0b95\u0bc1, IEEE C57.152-2013, \u201c\u0ba4\u0bbf\u0bb0\u0bb5 \u0ba8\u0bbf\u0bb0\u0baa\u0bcd\u0baa\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0b95\u0bb3\u0bcd, \u0b92\u0bb4\u0bc1\u0b99\u0bcd\u0b95\u0bc1\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bbf\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0bb5\u0bbf\u0ba9\u0bc8\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd\u0b95\u0bb3\u0bbf\u0ba9\u0bcd \u0ba8\u0bcb\u0baf\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0b95\u0bb3 \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8\u0b95\u0bcd\u0b95\u0bbe\u0ba9 IEEE \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf\u201d\u0baf\u0bc8\u0baa\u0bcd \u0baa\u0bbe\u0bb0\u0bcd\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.\u201d<\/p>\n<p>\u0b9a\u0bb0\u0bbf\u0baf\u0bbe\u0ba9 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4 \u0bae\u0bc7\u0bb2\u0bbe\u0ba3\u0bcd\u0bae\u0bc8, \u0bae\u0bbf\u0ba9\u0bcd\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b86\u0baf\u0bc1\u0bb3\u0bc8 \u0baa\u0bb2 \u0baa\u0ba4\u0bcd\u0ba4\u0bbe\u0ba3\u0bcd\u0b9f\u0bc1\u0b95\u0bb3\u0bcd \u0ba8\u0bc0\u0b9f\u0bcd\u0b9f\u0bbf\u0ba4\u0bcd\u0ba4\u0bc1, \u0ba8\u0bc7\u0bb0\u0b9f\u0bbf \u0b9a\u0bc7\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b85\u0ba4\u0ba9\u0bcd \u0bb5\u0bbf\u0bb3\u0bc8\u0bb5\u0bbe\u0ba9 \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bbf\u0bb2\u0bcd \u0bae\u0bbf\u0bb2\u0bcd\u0bb2\u0bbf\u0baf\u0ba9\u0bcd \u0b95\u0ba3\u0b95\u0bcd\u0b95\u0bbe\u0ba9 \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0bb3\u0bcd\u0bb3 \u0b8e\u0ba4\u0bbf\u0bb0\u0bcd\u0baa\u0bbe\u0bb0\u0bbe\u0ba4 \u0b9a\u0bc6\u0baf\u0bb2\u0bbf\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc8\u0ba4\u0bcd \u0ba4\u0b9f\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0bb1\u0ba4\u0bc1. \u0b87\u0ba8\u0bcd\u0ba4\u0b95\u0bcd \u0b95\u0bca\u0bb3\u0bcd\u0b95\u0bc8\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb5\u0ba4\u0bbf\u0bb2\u0bcd \u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0ba4\u0bb2\u0bc0\u0b9f\u0bc1, \u0bae\u0bbf\u0ba9\u0bcd \u0b85\u0bae\u0bc8\u0baa\u0bcd\u0baa\u0bc1\u0baa\u0bcd \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bbf\u0bb2\u0bcd \u0b89\u0b99\u0bcd\u0b95\u0bb3\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd \u0bb5\u0bbe\u0bb4\u0bcd\u0b95\u0bcd\u0b95\u0bc8 \u0bae\u0bc1\u0bb4\u0bc1\u0bb5\u0ba4\u0bc1\u0bae\u0bcd \u0baa\u0bb2\u0ba9\u0bb3\u0bbf\u0b95\u0bcd\u0b95\u0bc1\u0bae\u0bcd.<\/p>\n<h2>\u0ba4\u0bca\u0b9f\u0bb0\u0bcd\u0baa\u0bc1\u0b9f\u0bc8\u0baf \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb3\u0b99\u0bcd\u0b95\u0bb3\u0bcd<\/h2>\n<ul>\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/C57.152\/\" target=\"_blank\" rel=\"noopener\">IEEE C57.152 \u0b89\u0bb0\u0bc1\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0ba8\u0bcb\u0baf\u0bb1\u0bbf\u0ba4\u0bb2\u0bcd \u0b95\u0bb3\u0b9a\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/transformer-oil-technical-guide\/\">\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbe\u0ba9\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bcd \u0ba4\u0bca\u0bb4\u0bbf\u0bb2\u0bcd\u0ba8\u0bc1\u0b9f\u0bcd\u0baa \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/distribution-transformer-guide\/\">\u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/power-distribution-transformers\/\">\u0bae\u0bbf\u0ba9\u0bcd \u0bb5\u0bbf\u0ba8\u0bbf\u0baf\u0bcb\u0b95 \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0ba4\u0bc0\u0bb0\u0bcd\u0bb5\u0bc1\u0b95\u0bb3\u0bcd<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/transformer-losses-p0-pk-tco-comparison\/\">\u0bae\u0bbe\u0bb1\u0bcd\u0bb1\u0bbf\u0baf\u0bbf\u0ba9\u0bcd \u0b87\u0bb4\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd TCO \u0b92\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bc1<\/a><\/li>\n<li><a href=\"https:\/\/xbrele.com\/ta\/sfra-transformer-testing-guide\/\">SFRA \u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u0b9f\u0bbf\u0bb0\u0bbe\u0ba9\u0bcd\u0bb8\u0bcd\u0b83\u0baa\u0bbe\u0bb0\u0bcd\u0bae\u0bb0\u0bcd \u0b8e\u0ba3\u0bcd\u0ba3\u0bc6\u0baf\u0bbf\u0ba9\u0bcd ppm-\u0b87\u0bb2\u0bcd \u0b89\u0bb3\u0bcd\u0bb3 \u0b88\u0bb0\u0baa\u0bcd\u0baa\u0ba4\u0bae\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bbe\u0bb0\u0bcd\u0baa\u0bc1 \u0ba8\u0bbf\u0bb1\u0bc8\u0bb5\u0bc1\u0bb1\u0bcd\u0bb1 \u0ba4\u0ba9\u0bcd\u0bae\u0bc8\u0baf\u0bc8, \u0b89\u0bb2\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0bae\u0bcd \u0bae\u0bc1\u0bb1\u0bc8\u0b95\u0bb3\u0bcd, \u0bb5\u0bb0\u0bae\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0bb5\u0bbf\u0bb5\u0bb0\u0b95\u0bcd\u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0baa\u0bc1\u0bb0\u0bbf\u0ba8\u0bcd\u0ba4\u0bc1\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bc1\u0b99\u0bcd\u0b95\u0bb3\u0bcd.<\/p>","protected":false},"author":3,"featured_media":3704,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[26],"tags":[],"class_list":["post-3709","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-distribution-transformer-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3709","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=3709"}],"version-history":[{"count":5,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3709\/revisions"}],"predecessor-version":[{"id":3777,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/3709\/revisions\/3777"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/3704"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=3709"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=3709"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=3709"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}