{"id":4150,"date":"2026-08-04T09:00:00","date_gmt":"2026-08-04T09:00:00","guid":{"rendered":"https:\/\/xbrele.com\/?p=4150"},"modified":"2026-08-18T14:58:44","modified_gmt":"2026-08-18T14:58:44","slug":"vcb-mechanical-trip-free-test-sequence-blocking-conditions-and-acceptance-evidence","status":"publish","type":"post","link":"https:\/\/xbrele.com\/ta\/vcb-mechanical-trip-free-test-sequence-blocking-conditions-and-acceptance-evidence\/","title":{"rendered":"VCB Mechanical Trip-Free Test: Sequence Blocking Conditions and Acceptance Evidence"},"content":{"rendered":"<h2>\u0bae\u0bc1\u0b95\u0bcd\u0b95\u0bbf\u0baf\u0b95\u0bcd \u0b95\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bc1\u0b95\u0bb3\u0bcd<\/h2>\n<ul>\n<li>Confirm the project duty and applicable requirements for VCB before selection or service work.<\/li>\n<li>\u0b86\u0ba4\u0bbe\u0bb0\u0bae\u0bb1\u0bcd\u0bb1 \u0b8a\u0b95\u0b99\u0bcd\u0b95\u0bb3\u0bc1\u0b95\u0bcd\u0b95\u0bc1\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb2\u0bbe\u0b95, \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b9a\u0bc6\u0baf\u0bcd\u0baf\u0baa\u0bcd\u0baa\u0b9f\u0bcd\u0b9f \u0b86\u0baf\u0bcd\u0bb5\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b9a\u0bcb\u0ba4\u0ba9\u0bc8 \u0b86\u0ba4\u0bbe\u0bb0\u0b99\u0bcd\u0b95\u0bb3\u0bc8\u0baa\u0bcd \u0baa\u0baf\u0ba9\u0bcd\u0baa\u0b9f\u0bc1\u0ba4\u0bcd\u0ba4\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<li>\u0b87\u0bb1\u0bc1\u0ba4\u0bbf \u0b8f\u0bb1\u0bcd\u0bb1\u0bc1\u0b95\u0bcd\u0b95\u0bca\u0bb3\u0bcd\u0bb3\u0bb2\u0bcd, \u0baa\u0bb0\u0bbe\u0bae\u0bb0\u0bbf\u0baa\u0bcd\u0baa\u0bc1 \u0bae\u0bb1\u0bcd\u0bb1\u0bc1\u0bae\u0bcd \u0b92\u0baa\u0bcd\u0baa\u0b9f\u0bc8\u0baa\u0bcd\u0baa\u0bc1 \u0b86\u0bb5\u0ba3\u0b99\u0bcd\u0b95\u0bb3\u0bc8 \u0b89\u0baa\u0b95\u0bb0\u0ba3\u0baa\u0bcd \u0baa\u0ba4\u0bbf\u0bb5\u0bc1\u0b95\u0bb3\u0bc1\u0b9f\u0ba9\u0bcd \u0b9a\u0bc7\u0bb0\u0bcd\u0ba4\u0bcd\u0ba4\u0bc1\u0baa\u0bcd \u0baa\u0bbe\u0ba4\u0bc1\u0b95\u0bbe\u0b95\u0bcd\u0b95\u0bb5\u0bc1\u0bae\u0bcd.<\/li>\n<\/ul>\n<p>The **vcb mechanical trip free test** is one of the most safety-critical verification steps performed on a vacuum circuit breaker before it enters service. Unlike routine close-open timing tests, the trip-free test deliberately attempts to hold the closing command active while simultaneously issuing a trip command, confirming that the breaker cannot be latched closed against a persistent protection signal. Failing this test means the breaker can be forced into a sustained closed position even when a fault is present \u2014 an outcome that can destroy equipment, injure personnel, and collapse a busbar section.<\/p>\n<p>This article explains the electrical and mechanical sequence that makes trip-free operation possible, identifies the blocking conditions that must be satisfied before the test begins, describes the evidence commissioning engineers must record, and answers the most common field questions about acceptance criteria.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-mechanical-trip-free-test-sequence-blocking-conditions-and-acceptance-evidence-fig-01.webp\" alt=\"XBRELE VCB Mechanical Trip-Free Test: Sequence Blocking Conditions and Acceptance Evidence - engineering anatomy\" \/><\/figure>\n<p>\u2014<\/p>\n<h3>Why Trip-Free Operation Matters in MV Switchgear<\/h3>\n<p>A vacuum circuit breaker operates under a fundamental safety principle: a trip command must always dominate a simultaneous close command. This is sometimes called the &quot;trip priority&quot; principle, and it is engineered into the breaker at two independent levels \u2014 the mechanical trip-free mechanism and the electrical anti-pumping scheme.<\/p>\n<p>At the mechanical level, the trip-free mechanism is a linkage arrangement that physically prevents the main contacts from being held closed if the trip latch is released. No amount of sustained electrical energy at the close coil can overcome the mechanical decoupling that occurs once the trip latch is freed. This is important because electrical anti-pumping relays can fail, wiring can be incorrect, and control voltage can fluctuate \u2014 the mechanical mechanism is the last line of defence.<\/p>\n<p>At the electrical level, the anti-pumping relay (sometimes designated Y or APR in manufacturer wiring diagrams) prevents the close coil from being re-energised after a trip-free event has caused the breaker to open, as long as the close command remains latched. Manufacturer circuit diagrams, such as those published for ABB&#x27;s SecoVac series, identify a dedicated trip-free limit switch alongside the close coil, trip coil, anti-pumping relay, energy-storage switches, and auxiliary contacts; test points must therefore be taken from the approved breaker wiring diagram rather than from generic schematics.<\/p>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/62785\" target=\"_blank\" rel=\"noopener\">\u0b90\u0b87\u0b9a\u0bbf 62271-100<\/a>, which applies to AC circuit-breakers rated above 1 kV, sets the framework under which mechanical performance is characterised, and a project-controlled edition of this standard together with the approved breaker documentation governs the specific verification procedure on any given project. Commissioning engineers should confirm which revision of IEC 62271-100 is referenced in the project specification before beginning any formal testing sequence. For the rated-data check, compare these conditions with the <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker-ratings\/\">\u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0bae\u0ba4\u0bbf\u0baa\u0bcd\u0baa\u0bc0\u0b9f\u0bcd\u0b9f\u0bc1 \u0bb5\u0bb4\u0bbf\u0b95\u0bbe\u0b9f\u0bcd\u0b9f\u0bbf<\/a>.<\/p>\n<p>\u2014<\/p>\n<h3>Key Electrical Components Involved in the Test Circuit<\/h3>\n<p>Understanding which components participate in the trip-free sequence is essential for placing test leads correctly and for interpreting unexpected results.<\/p>\n<p>**Close coil (CC):** Energised by a close command from a pushbutton, SCADA, or protection relay output. The coil drives the closing mechanism through the energy stored in the closing spring.<\/p>\n<p>**Trip coil (TC):** Energised by a trip command from a protection relay, lockout relay, or manual trip pushbutton. The coil releases the trip latch.<\/p>\n<p>**Trip-free limit switch (TFLS):** A position-dependent switch, unique to the trip-free function, that opens the close coil circuit at the moment the trip latch releases. ABB SecoVac wiring documentation explicitly identifies this switch as a discrete component separate from the standard auxiliary contacts. Its normally-closed state allows the closing sequence to proceed; its open state blocks re-energisation of the close coil.<\/p>\n<p>**Anti-pumping relay (APR):** A latching relay that picks up on a close command and seals in through its own contact; it then drops out only when the close command is removed. During a trip-free event, the APR prevents repeated close attempts while the operator or SCADA system holds the close command.<\/p>\n<p>**Energy-storage switches:** Cam-operated contacts that indicate whether the closing spring is charged. If the spring is discharged, these contacts block the close coil from energising, which is a different blocking condition from trip-free but equally important to verify.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-mechanical-trip-free-test-sequence-blocking-conditions-and-acceptance-evidence-fig-02.webp\" alt=\"XBRELE VCB Mechanical Trip-Free Test: Sequence Blocking Conditions and Acceptance Evidence - test measurement\" \/><\/figure>\n<p>\u2014<\/p>\n<h3>Pre-Test Blocking Conditions That Must Be Satisfied<\/h3>\n<p>Before the formal vcb mechanical trip free test sequence begins, a defined set of blocking conditions must be confirmed. Executing the test while any of these conditions is unmet can produce a false pass, a false fail, or an unsafe situation.<\/p>\n<p>**1. Breaker racked to the test position.** The breaker must be in the isolated or test position so that main contacts cannot connect to the primary conductors. Schneider Electric&#x27;s EvoPacT guidance for MV circuit-breakers states that, before initial energisation, correct operation of the closing and opening auxiliary releases must be verified with safe work controls and the applicable equipment documentation in place. The same principle applies during commissioning tests: primary isolation must be confirmed before any control circuit manipulation. Use the <a href=\"https:\/\/xbrele.com\/ta\/vacuum-circuit-breaker\/\">XBRELE \u0bb5\u0bc6\u0bb1\u0bcd\u0bb1\u0bbf\u0b9f \u0bae\u0bbf\u0ba9\u0bcd\u0b9a\u0bc1\u0bb1\u0bcd\u0bb1\u0bc1 \u0bae\u0bc1\u0bb1\u0bbf\u0baa\u0bcd\u0baa\u0bbe\u0ba9\u0bcd \u0bb5\u0b95\u0bc8<\/a> to screen available equipment against the project duty before requesting a final configuration.<\/p>\n<p>**2. Closing spring fully charged.** The energy-storage switch must indicate that the spring is charged. If the spring is discharged, the close coil cannot drive the mechanism and the test cannot reach the point where the trip-free latch is meaningful.<\/p>\n<p>**3. Control voltage within tolerance.** Most MV circuit-breakers specify a control voltage range of 85\u2013110% of rated DC voltage for reliable coil operation. Testing outside this band can cause borderline coil pickup and unreliable results.<\/p>\n<p>**4. Anti-pumping relay reset.** The APR must be in its de-energised state, confirmed by measuring the coil and checking the relevant auxiliary contact state. A stuck APR will block the close command from reaching the close coil, producing a false trip-free indication.<\/p>\n<p>**5. Auxiliary contacts verified.** The 52a and 52b contact positions must reflect the actual breaker state \u2014 open contacts correctly showing open position. Any mismatch suggests a cam-follower problem or wiring error that must be resolved before the trip-free sequence.<\/p>\n<p>**6. Wiring diagram version confirmed.** Because the trip-free limit switch test point location varies by manufacturer, model, and revision, the wiring diagram used during testing must match the as-built breaker. Test leads must be placed at the terminals specified in the approved breaker wiring diagram.<\/p>\n<p>\u2014<\/p>\n<h3>Step-by-Step Test Sequence and Measurement Method<\/h3>\n<p>The following sequence describes the standard vcb mechanical trip free test as performed during factory acceptance testing (FAT) or site acceptance testing (SAT). Deviations required by project-specific documents take precedence.<\/p>\n<p>**Step 1 \u2014 Establish baseline measurements.** With the breaker open and spring charged, measure and record control voltage at the panel terminals and at the breaker plug. Record the as-found resistance of the close coil and trip coil using a low-ohm meter. Compare readings against manufacturer data sheets.<\/p>\n<p>**Step 2 \u2014 Apply a sustained close command.** Using a maintained-contact test switch (not a momentary pushbutton), energise the close coil. The breaker should close. Record the time from command to contact make using a timing relay or event recorder. The auxiliary 52a contact should transition within the manufacturer&#x27;s specified time window, typically less than 100 ms for most MV VCBs.<\/p>\n<p>**Step 3 \u2014 Maintain the close command and apply a simultaneous trip command.** Without releasing the close command, energise the trip coil. A correctly functioning trip-free mechanism will cause the main contacts to open and will then prevent them from reclosing as long as the close command remains applied. The breaker must come to rest in the open position. Use the <a href=\"https:\/\/xbrele.com\/ta\/vcb-closing-opening-failure-troubleshooting\/\">VCB operating-failure troubleshooting<\/a> to separate control-circuit, coil, interlock, and mechanism causes after a failed operation.<\/p>\n<p>**Step 4 \u2014 Confirm the breaker remains open.** With both close command and trip command maintained, verify the breaker position by reading the 52a\/52b auxiliary contacts and by visual inspection of the mechanical position indicator. No re-closing attempt should occur.<\/p>\n<p>**Step 5 \u2014 Release the close command, then the trip command.** Remove the close command first. Confirm the APR drops out. Then remove the trip command. The breaker should remain open and the spring should be charged (by the anti-reclose spring-charge motor if fitted). The system is now ready for a normal close sequence.<\/p>\n<p>**Step 6 \u2014 Repeat in the opposite energisation order.** Issue a trip command first, then apply the close command simultaneously. The breaker must not close. This verifies that the trip-free condition holds regardless of command sequence timing.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-mechanical-trip-free-test-sequence-blocking-conditions-and-acceptance-evidence-fig-03.webp\" alt=\"XBRELE VCB Mechanical Trip-Free Test: Sequence Blocking Conditions and Acceptance Evidence - application context\" \/><\/figure>\n<p>\u2014<\/p>\n<h3>Acceptance Evidence and Documentation Requirements<\/h3>\n<p>Acceptance evidence for the vcb mechanical trip free test must be sufficient to demonstrate the test was performed under defined conditions, that results were objective, and that the evidence is traceable to the as-built hardware.<\/p>\n<p>**Event recorder trace or time-stamped data logger output.** A paper printout or exported CSV file showing the coil energisation times, contact transition times, and command states across all six steps. The trace must be labelled with breaker tag, panel ID, date, and tester identification.<\/p>\n<p>**Wiring diagram mark-up.** A copy of the approved wiring diagram with test point locations annotated in red ink or equivalent controlled revision, signed and dated by the commissioning engineer. This satisfies the requirement that test points were taken from the approved breaker wiring diagram rather than from memory or generic sources.<\/p>\n<p>**Coil resistance record.** Tabulated before-test and after-test resistance values for both the close coil and trip coil. A significant change in resistance between measurements can indicate coil heating or insulation degradation during repeated test sequences.<\/p>\n<p>**Photographic evidence.** A photograph of the mechanical position indicator in the open position following Step 4, and a photograph of the test configuration showing maintained-contact test switches and instrumentation connections.<\/p>\n<p>**Sign-off matrix.** A test record sheet, typically generated from the project&#x27;s commissioning procedure, with columns for step description, acceptance criterion, as-found result, pass\/fail indication, and signatures from the commissioning engineer, the witness (client or manufacturer representative), and the responsible engineer. The <a href=\"https:\/\/xbrele.com\/ta\/vcb-fat-sat-acceptance-test-checklist\/\">VCB acceptance-test checklist<\/a> provides a companion structure for acceptance criteria, results, and closeout records.<\/p>\n<p>Where a factory acceptance test is required under IEC 62271-100, the manufacturer&#x27;s quality records must be made available, and the project-controlled edition of the standard governs which test clauses apply. Site acceptance testing typically references both the standard and the project specification, with the more stringent requirement taking precedence.<\/p>\n<p>\u2014<\/p>\n<h3>Common Failure Modes and Their Diagnostic Signatures<\/h3>\n<p>Field experience identifies several repeating failure modes during the vcb mechanical trip free test.<\/p>\n<p>**Trip-free limit switch stuck closed:** The TFLS fails to open when the trip latch releases. The close coil remains energised, the mechanism attempts to reclose, and the breaker oscillates between open and closed. Diagnostic signature: the event trace shows repeated 52a transitions after the trip command. Corrective action: inspect TFLS cam follower for wear or misalignment and replace if necessary.<\/p>\n<p>**Anti-pumping relay wiring error:** The APR contact is wired in the trip circuit rather than the close circuit, or the APR coil is connected to the wrong potential. The test appears to pass initially but the APR does not seal in, allowing a subsequent momentary close command to re-energise the close coil after the trip. Diagnostic signature: the APR coil shows no voltage during a maintained close command.<\/p>\n<p>**Close coil energised from wrong supply rail:** In dual-supply panels, the close coil and trip coil may be on different supply rails with independent MCBs. If the trip coil supply rail MCB trips during testing (e.g. due to an earth fault in a test lead), the trip command cannot be issued, and the breaker remains closed under a maintained close command \u2014 a false pass. Diagnostic signature: trip coil resistance reads correctly but coil does not operate when energised.<\/p>\n<p>**Mechanical trip latch worn:** The trip latch does not release cleanly, causing a delayed or partial trip. The breaker main contacts open partially but do not reach the fully open position within the specified time. Diagnostic signature: timing trace shows 52b transition exceeding specification; mechanical position indicator shows mid-position.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/xbrele.com\/wp-content\/uploads\/2026\/07\/vcb-mechanical-trip-free-test-sequence-blocking-conditions-and-acceptance-evidence-fig-04.webp\" alt=\"XBRELE VCB Mechanical Trip-Free Test: Sequence Blocking Conditions and Acceptance Evidence - supply handover\" \/><\/figure>\n<p>\u2014<\/p>\n<h2>\u0b85\u0b9f\u0bbf\u0b95\u0bcd\u0b95\u0b9f\u0bbf \u0b95\u0bc7\u0b9f\u0bcd\u0b95\u0baa\u0bcd\u0baa\u0b9f\u0bc1\u0bae\u0bcd \u0b95\u0bc7\u0bb3\u0bcd\u0bb5\u0bbf\u0b95\u0bb3\u0bcd<\/h2>\n<h3>What is the difference between the trip-free test and the anti-pumping test?<\/h3>\n<p>The trip-free test verifies that the mechanical linkage prevents the breaker from being held closed against a simultaneous trip command, regardless of electrical circuit state. The anti-pumping test verifies that the electrical APR circuit prevents the close coil from being re-energised after the breaker trips on a maintained close command. Both tests apply a simultaneous close and trip command, but the trip-free test evaluates the mechanical outcome \u2014 does the breaker open and stay open mechanically \u2014 while the anti-pumping test evaluates the electrical outcome \u2014 does the APR seal in and block the close coil. A breaker can pass the anti-pumping test and still fail the mechanical trip-free test if the TFLS is defective, because the APR may correctly block re-energisation of the close coil but the mechanical latch may still hold the contacts closed momentarily.<\/p>\n<h3>What is the role of the trip-free limit switch in the control circuit?<\/h3>\n<p>The trip-free limit switch (TFLS) is a cam-operated, position-dependent switch that opens the close coil supply circuit at the instant the trip latch begins to release. It is a discrete component identifiable on the manufacturer&#x27;s wiring diagram, separate from the standard 52a\/52b auxiliary contacts. When the trip command releases the mechanical latch, the TFLS cam follower moves to a position that opens the TFLS contact, interrupting current through the close coil before the main contacts have reached their open position. This mechanical interruption of the close coil current is independent of the APR and of control voltage, making it the primary trip-free safeguard. Without a functioning TFLS, the close coil would remain energised through the entire opening stroke and could attempt to re-close the breaker.<\/p>\n<h3>What is the minimum documentation required to pass a formal trip-free acceptance test?<\/h3>\n<p>Formal acceptance requires, at minimum: a time-stamped event recorder trace covering all test steps with coil and contact states visible; a tabulated record of close coil and trip coil resistances measured before and after the test sequence; an annotated copy of the approved breaker wiring diagram showing the test point terminals used; photographic evidence of the mechanical position indicator in the open state during Step 4; and a signed test record sheet identifying the breaker tag, panel ID, test date, revision of the applicable standard (typically IEC 62271-100 under the project-controlled edition), tester name, and witness name. Project specifications may require additional items such as video evidence, third-party witness sign-off, or upload to a digital quality management system.<\/p>\n<h3>What is the correct control voltage range for testing VCB coils?<\/h3>\n<p>Most medium-voltage vacuum circuit-breaker manufacturers specify that the trip coil and close coil must operate reliably across a control voltage band of 85% to 110% of rated DC voltage. The nominal voltage is typically 110 V DC or 125 V DC for utility and industrial switchgear, and 24 V DC or 48 V DC for some industrial applications. The trip-free test should be performed with control voltage at nominal to establish a baseline, and may additionally be repeated at 85% of nominal to confirm that the trip coil operates reliably under low-voltage conditions. Testing at 110% of nominal verifies that coil insulation is not stressed by over-voltage. The specific test voltage levels are governed by the project specification and the IEC 62271-100 edition referenced in the commissioning procedure; any deviation from the manufacturer&#x27;s stated coil rating requires engineering approval.<\/p>\n<h3>What is the consequence of skipping the trip-free test during commissioning?<\/h3>\n<p>Skipping the vcb mechanical trip free test means there is no objective evidence that the trip-free mechanism functions correctly in the as-installed breaker. Mechanical trip-free mechanisms can be damaged during transport, during racking operations, or as a result of a factory assembly error that passed visual inspection but was not caught during routine factory testing. If a defective trip-free mechanism is not identified before energisation, the first protection trip in service may fail to open the breaker, sustaining fault current through the primary conductors until an upstream device operates or until the breaker is damaged beyond recovery. Beyond the equipment damage risk, regulatory frameworks in most jurisdictions treat the omission of a specified commissioning test as a non-conformance that may invalidate insurance cover and delay project handover. Project documentation typically requires the commissioning engineer to certify that all specified tests have been performed before a hold point can be cleared for energisation.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quick Takeaway Confirm the project duty and applicable requirements for VCB before selection or service work. Use recorded inspection and test evidence instead of unsupported assumptions. Keep the final acceptance, maintenance, and handover documents with the equipment record. The **vcb mechanical trip free test** is one of the most safety-critical verification steps performed on a [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":4145,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-4150","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-circuit-breaker-knowledge"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/4150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/comments?post=4150"}],"version-history":[{"count":2,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/4150\/revisions"}],"predecessor-version":[{"id":4272,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/posts\/4150\/revisions\/4272"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media\/4145"}],"wp:attachment":[{"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/media?parent=4150"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/categories?post=4150"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xbrele.com\/ta\/wp-json\/wp\/v2\/tags?post=4150"}],"curies":[{"name":"\u0b9f\u0baa\u0bbf\u0bb3\u0bcd\u0baf\u0bc2\u0baa\u0bbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}