MV & HV VACUUM CIRCUIT BREAKERS

ZW20 Vacuum Circuit Breaker for 12kV Overhead Distribution Networks

XBRELE designs and manufactures outdoor ZW20 vacuum circuit breakers for 12 kV medium-voltage power systems, providing reliable protection and automation for overhead distribution networks. ZW20 series can be configured as automatic reclosers for feeder and transformer protection.

XBRELE supplies the ZW20 vacuum circuit breaker series to utilities and industrial users in India, the Middle East, Russia and other emerging markets, offering flexible configurations for new projects and replacement of existing switchgear.

ZW20 series snapshot
ZW20 is an outdoor 12 kV vacuum circuit breaker that can operate as an automatic recloser on medium-voltage overhead lines, protecting feeders and distribution transformers.
ZW20 · 12kV · Outdoor VCB
Typical use cases: 12 kV overhead line reclosers, MV feeders and transformer protection points in utility and industrial distribution systems.
Series overview

ZW20 vacuum circuit breaker for 12kV overhead networks

The ZW20 vacuum circuit breaker is an outdoor 12 kV switching device for medium-voltage overhead distribution networks. Each ZW20 unit integrates the vacuum interrupter, solid-insulated embedded pole, operating mechanism and current transformers into a compact, fully enclosed body suitable for long-term field operation.

With the embedded pole design, the ZW20 vacuum circuit breaker achieves high insulation level and protects the interrupter from moisture, dust and pollution. Together with a stable spring operating mechanism, it delivers reliable opening and closing performance under frequent switching conditions on distribution feeders.

In standard configuration the ZW20 works as a pole-mounted vacuum circuit breaker. When it is equipped with a suitable controller and sensors, the same ZW20 vacuum circuit breaker can be configured as an automatic recloser for feeder protection and distribution automation on 12 kV networks.

For a broader view of XBRELE’s outdoor vacuum circuit breakers, please visit the vacuum circuit breaker pillar page .

Technical data & installation dimensions

ZW20-12F — specifications and outline drawings

Select the voltage level below to view the corresponding product photo, key electrical ratings, and outline & mounting dimensions for engineering design and selection.

ZW20-12F · 12kV
ZW20-12F outdoor vacuum circuit breaker 12kV – XBRELE
ZW20-12F outdoor vacuum circuit breaker (12kV), pole-mounted construction with embedded pole.

ZW20-12F technical overview

ZW20-12F is an outdoor vacuum recloser for 12kV overhead distribution networks, designed to provide reliable protection and automation. The unit features solid insulation and an embedded pole for enhanced durability and protection.

This recloser integrates a vacuum interrupter and spring operating mechanism, ensuring long-term performance under frequent operations in challenging outdoor environments.

12kV Outdoor Pole-mounted Embedded pole

The table below lists the main electrical ratings for ZW20-12F.

Key electrical ratings — ZW20-12F

Values according to the ZW20-12F technical parameter sheet.

No.ItemUnitZW20-12F
1Rated voltagekV12
2Rated currentA630 / 1250
3Rated frequencyHz50
4Rated short-circuit breaking currentkA20 / 25
5Rated short-circuit closing current (peak)kA50 / 63
6Mechanical lifeoperations10,000
7Rated operating voltageVAC/DC220
8Power-frequency withstand voltage (1 min, phase-to-phase)kV34
9Lightning impulse withstand voltage (phase-to-phase)kV75 / 85
10Weightkg≈ 140
11Rated current cut-off timestimes10,000
12Rated short-circuit breaking timestimes30
13Power frequency withstand voltage 1 minkV34
14Lightning impulse withstand voltagekV75/85
15Contact spacingmm9
16Contact stroke of contactmm3
17Average opening speedm/s1.2±0.2
18Average closing speedm/s0.6±0.2
19Rated operating voltageVAC/DC220
20SF6 gas rated pressureMPa0

Outline & mounting dimensions — ZW20-12F

Outline and mounting dimensions for typical ZW20-12F pole-mounted installation.

ZW20-12F outline and mounting dimensions – XBRELE
ZW20-12F outline & mounting dimensions for pole-mounted installation.
ItemSymbolValue (mm)Note
Overall heightH—Overall height of breaker assembly
Overall widthW—Including phase spacing
Mounting hole spacing (horizontal)L1—Base horizontal bolt distance
Mounting hole spacing (vertical)L2—To match cross-arm or steel structure
Mounting hole sizeΦ—Oval or round hole diameter
Configuration & options

Protection, control and automation around the ZW20 series

ZW20 outdoor vacuum reclosers can be combined with protection relays, CTs/VTs and communication devices to form complete pole-mounted switching and automation solutions for distribution networks.

Protection

Protection & measuring combinations

Build a complete protection scheme around the ZW20 using your preferred relays and instrument transformers.

  • Feeder over-current and earth-fault protection
  • Directional / non-directional protection according to system design
  • Integrated CTs for metering and protection functions
  • Support for recloser curves and sectionalizing logic
Control

Operating & control options

Flexible operating configurations to match manual, local and remote control requirements.

  • Spring operating mechanism with motor charging
  • Local/remote control selector with clear position indication
  • AUX contacts for SCADA status feedback (open/close/ready)
  • Compatible with pole-mounted control cabinets and RTUs
Automation

Distribution automation & communication

When combined with suitable controllers, ZW20 breakers can be used in automated distribution systems and smart grid projects.

  • Support for common protocols via external IEDs (Modbus, IEC 60870-5-104, etc.)
  • Remote open/close and status monitoring through SCADA
  • Fault location, isolation and service restoration (FLISR) schemes
  • Customized wiring and terminal arrangements on request
Manufacturing & quality control

How XBRELE builds reliable ZW20 outdoor vacuum circuit breakers

Behind every ZW20 unit there is a controlled manufacturing flow – from embedded pole casting to routine testing – designed to ensure long-term reliability on harsh outdoor lines.

From embedded pole to finished breaker

XBRELE manufactures the vacuum interrupter pole assemblies, operating mechanism and housing in a coordinated process. Each step is monitored and recorded for traceability of every ZW20 unit.

  • 01

    Vacuum interrupter & pole assembly

    Vacuum interrupters are checked for stroke, over-travel and resistance, then built into the solid pole.

  • 02

    Solid insulation casting & curing

    Epoxy insulation is degassed, poured and cured to form a compact embedded pole resistant to tracking.

  • 03

    Mechanism integration & adjustment

    The spring mechanism is assembled, lubricated and tuned so speeds, timing and bounce meet ZW20 limits.

  • 04

    Final assembly & sealing

    Poles, CTs, terminals and enclosure parts are combined into a sealed outdoor body with anti-corrosion coating.

  • 05

    Routine testing & inspection

    Each breaker passes electrical, mechanical and dielectric tests before packing and shipment.

Electrical & dielectric tests

Routine tests for every ZW20

Electrical routine tests verify insulation level and switching performance.

Insulation & switching verification

  • Power-frequency withstand between phases and to earth
  • Lightning impulse withstand on sample basis
  • Contact resistance check for each main circuit
  • Mechanical operating tests for O / CO sequences

Routine-test records can be supplied with the shipment if required.

Mechanical reliability

  • Type-test verification of 10,000 mechanical operations
  • Check of opening / closing speeds within limits
  • Control of closing bounce time and pole synchronism
  • Environmental checks for lubrication and low-temperature duty

Documentation & traceability

  • Type-test reports and routine-test certificates
  • Factory inspection records with serial number traceability
  • Outline drawings & terminal diagrams in editable format
  • Recommended maintenance guidelines for field crews

FAT / QAP / ITP witness testing can be arranged for utility or EPC projects.

Delivery, export packing & support

Lead time and project support for ZW20-12F outdoor vacuum reclosers

XBRELE supplies ZW20-12F outdoor vacuum reclosers and sectionalizers for utility and EPC projects worldwide, with export-ready packing, flexible lead times and technical support for tender and execution stages.

Lead time & minimum order

Standard ZW20-12F configurations can usually be produced within a few weeks after order confirmation and technical clarification.

  • Typical lead time: about 20–30 days for standard units
  • Small batches for pilot projects are acceptable
  • Mixed orders with other XBRELE VCB series can be combined in one shipment
  • Urgent requirements can be discussed case by case

Export packing & logistics

ZW20-12F reclosers are packed for long-distance sea or land transport, with protection against vibration, moisture and corrosion.

  • Strong export wooden cases with internal fixing of the breaker
  • Circuit breaker, controller and CTs packed with clear labels
  • Support for FOB, CIF or door-to-port delivery terms
  • Shipping documents and packing list prepared according to client’s instructions

Engineering & project support

XBRELE can assist panel builders, OEMs and utilities during selection, tender preparation and project execution for ZW20-12F applications.

  • Support with single-line diagrams and equipment schedules
  • Outline drawings, wiring diagrams and data sheets for approval
  • Type-test reports and routine-test certificates for documentation
  • FAT / QAP / ITP witness testing can be arranged when required
FAQ · ZW20 Series

Frequently asked questions about the ZW20 vacuum circuit breaker

Below are typical questions from utilities, EPC contractors and distributors when selecting the ZW20 vacuum circuit breaker for 12 kV overhead distribution networks and recloser projects.

What is the main difference between ZW20 and ZW32? +
Both products are outdoor medium-voltage vacuum circuit breakers, but ZW20 is typically used as a pole-mounted switching point on 12 kV lines and can be configured as an automatic recloser. ZW32 is a more compact pole-mounted breaker platform with different ratings and outline dimensions. When planning a project, the ZW20 vacuum circuit breaker is often selected where an integrated control cubicle and recloser functions are required.
Can the ZW20 vacuum circuit breaker be supplied as an automatic recloser? +
Yes. By adding a suitable controller, auxiliary CTs/VTs and wiring, the ZW20 vacuum circuit breaker can be configured as an automatic recloser with programmable protection curves and reclosing sequences. XBRELE can provide a complete ZW20 recloser package or cooperate with the customer’s specified controller brand.
Where is the ZW20 vacuum circuit breaker typically installed? +
The ZW20 vacuum circuit breaker is installed on concrete or steel poles, usually at feeder branches, section points or near pole-mounted transformers. Designers use the outline & mounting dimensions on this page to match cross-arms, brackets and hardware for the 12 kV overhead line.
What protection functions can be implemented with ZW20? +
With a suitable protection relay or recloser controller, ZW20 can provide phase over-current, earth-fault protection, sensitive earth-fault, cold-load pick-up and other functions. CTs/VTs mounted with the ZW20 vacuum circuit breaker supply the necessary signals for metering and protection.
What documentation and test reports are available for ZW20? +
XBRELE can provide outline drawings, terminal diagrams, type-test reports, routine-test reports and factory inspection records for the ZW20 vacuum circuit breaker. For utility or EPC projects, QAP/ITP documents and FAT witness testing can also be arranged according to the specification.
What is the typical delivery time for the ZW20 vacuum circuit breaker? +
For standard 12 kV ZW20 configurations, the typical lead time is about 15–25 days after order confirmation. For customized designs with special controllers, CTs/VTs or testing requirements, lead time is usually 25–35 days depending on quantity and project scope.
Which international standards are used as reference for ZW20 testing? +
ZW20 outdoor vacuum circuit breakers are designed and type tested with reference to the IEC 62271 series for high-voltage switchgear, in particular IEC 62271-100 for high-voltage AC circuit-breakers. For more information about the scope and latest edition of IEC 62271-100, you can refer to the official IEC webstore page IEC 62271-100 .