Get CatalogFrom heavy-duty low voltage (LV) contactors for mining to medium voltage (MV) vacuum contactors for switchgear. XBRELE offers reliable switching solutions with mechanical life up to 1 million operations for motors, transformers, and capacitor banks.
Vacuum contactors are the ideal solution for applications requiring frequent operations where circuit breakers are not suitable. XBRELE offers a complete spectrum of switching technologies, from low-voltage (1.14kV) units for mining equipment to medium-voltage (40.5kV) contactors for high-power networks.
Our portfolio includes the robust CKG & JCZ series for standard MV motor control and the premium LCZ/LZNJ series featuring solid embedded poles for harsh, dusty environments.
Uniquely, we also provide high-current Low Voltage (LV) vacuum contactors (up to 3200A) designed specifically for 1140V and 2kV industrial systems. Whether for a soft starter cabinet in a cement plant or a capacitor bank in a utility substation, our contactors deliver maintenance-free performance with electrical holding or mechanical latching options.
XBRELE supplies four main vacuum contactor series covering 1.14kV, 7.2kV, 12kV and 40.5kV. From heavy-duty mining contactors to precision MV capacitor switches, we provide the right solution for every industrial and utility application.
CKG vacuum contactors are the workhorse MV contactors for 3.3kV, 6.6kV and 11kV panels in India. With rated voltages of 7.2kV and 12kV and currents from 160A up to 630A, they are extensively used for motor feeders and specialized back-to-back capacitor bank switching.


JCZ vacuum contactors are compact 7.2kV and 12kV contactors with rated currents from 160A to 630A. They are ideal for indoor metal-enclosed switchgear, ring main units and compact MCCs where panel depth is limited but high reliability is essential.
The LCZ medium-voltage range features enclosed pole designs and specialized plateau types (GF models) suitable for altitudes up to 3500m. The portfolio extends up to 40.5kV, offering robust single-pole solutions for high-voltage feeder automation and traction power.


This specialized range covers low-voltage (1.14kV) heavy-duty contactors for mining and industrial drives, as well as the LZNJ solid-embedded pole series. The solid insulation technology protects the vacuum interrupter from dust, moisture, and external impact.
XBRELE vacuum contactors utilize sealed vacuum interrupters, robust air or solid-embedded (resin) insulation systems, and reliable electromagnetic or mechanical-latching mechanisms. Our designs are optimized for both low voltage high-current industrial applications and medium voltage distribution networks.
XBRELE vacuum contactors are engineered for the most demanding frequent switching duties. Our solutions power industrial motor control centers, mining hoists, and utility capacitor banks, offering robust performance across Low Voltage (1.14kV) and Medium Voltage (up to 40.5kV) networks.
Frequent starting of MV (3.3kV–11kV) and LV (1.14kV) motors for pumps, fans, and crushers in cement, steel, and petrochemical plants.
Specialized 1.14kV vacuum contactors for mining hoists, conveyors, and explosion-proof starters requiring no exposed arc and high vibration resistance.
Zero-bounce CKG series designed for back-to-back capacitor switching in power factor correction panels, minimizing inrush current and reignition risks.
Compact, maintenance-free contactors (LZNJ/LCZ) ideal for integration into high-voltage soft starter cabinets and variable frequency drives (VFDs).
XBRELE is a comprehensive vacuum switching specialist. By manufacturing our own vacuum interrupters, **solid embedded poles**, and operating mechanisms, we ensure consistent quality across our CKG, JCZ, LCZ, and Low Voltage CKJ series[cite: 1309, 1614].
We produce not only vacuum interrupters but also **resin-embedded poles** (LZNJ series) in-house. This vertical integration ensures superior insulation and impact resistance for harsh mining and industrial environments.
Our contactors are engineered for the toughest jobs: 1140V mining hoists, **high-voltage soft starters**, and frequent-switching electric arc furnaces where standard breakers fail.
Featuring patented **Zero-Bounce technology** (CKG4-12L) to eliminate arc reignition in capacitor banks, and **Electric Repulsion mechanisms** for ultra-fast response in critical circuits.
Validated for **C2 class capacitive switching** and extreme mechanical endurance—up to **1,000,000 operations** for our Low Voltage series.
Short technical answers for panel builders and industrial users selecting low and medium voltage switching devices for motor starters, mining equipment, and capacitor banks.